A comparison of three commercial IMRT treatment planning systems for selected pediatric cases

被引:3
|
作者
Eldesoky, Ismail [1 ]
Attalla, Ehab M. [1 ,2 ]
Elshemey, Wael M. [3 ]
Zaghloul, Mohamed S. [1 ,2 ]
机构
[1] Cairo Univ, Childrens Canc Hosp, Cairo, Egypt
[2] Cairo Univ, Natl Canc Inst, Cairo, Egypt
[3] Cairo Univ, Fac Sci, Dept Biophys, Cairo, Egypt
来源
关键词
KonRad; XiO; Prowess; IMRT; MODULATED RADIATION-THERAPY; NORMAL TISSUE; 2ND CANCERS; DELIVERY; NUMBER; RADIOTHERAPY; TOLERANCE;
D O I
10.1120/jacmp.v13i2.3742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work aimed at evaluating the performance of three different intensity-modulated radiotherapy (IMRT) treatment planning systems (TPSs) - KonRad, XiO and Prowess - for selected pediatric cases. For this study, 11 pediatric patients with different types of brain, orbit, head and neck cancer were selected. Clinical step-and-shoot IMRT treatment plans were designed for delivery on a Siemens ONCOR accelerator with 82-leaf multileaf collimators (MLCs). Plans were optimized to achieve the same clinical objectives by applying the same beam energy and the same number and direction of beams. The analysis of performance was based on isodose distributions, dose-volume histograms (DVHs) for planning target volume (PTV), the relevant organs at risk (OARs), as well as mean dose (D-mean), maximum dose (D-max), 95% dose (D-95), volume of patient receiving 2 and 5 Gy, total number of segments, monitor units per segment (MU/Segment), and the number of MU/cGy. Treatment delivery time and conformation number were two other evaluation parameters that were considered in this study. Collectively, the Prowess and KonRad plans showed a significant reduction in the number of MUs that varied between 1.8% and 61.5% (p-value = 0.001) for the different cases, compared to XiO. This was reflected in shorter treatment delivery times. The percentage volumes of each patient receiving 2 Gy and 5 Gy were compared for the three TPSs. The general trend was that KonRad had the highest percentage volume, Prowess showed the lowest (p-value = 0.0001). The KonRad achieved better conformality than both of XiO and Prowess. Based on the present results, the three treatment planning systems were efficient in IMRT, yet XiO showed the lowest performance. The three TPSs achieved the treatment goals according to the internationally approved standards.
引用
收藏
页码:124 / 135
页数:12
相关论文
共 50 条
  • [1] Comparison of different IMRT treatment planning systems on pediatric cases
    Cozzi, A. Fogliata
    Asell, M.
    Clivio, A.
    Dobler, B.
    Larsson, M.
    Lohr, F.
    Lorenz, F.
    Muzik, J.
    Nicolini, G.
    Polednik, M.
    Vanetti, V.
    Wolff, D.
    Wyttenbach, R.
    Cozzi, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S408 - S408
  • [2] Comparison of Prostate IMRT Plans From Three Commercial Treatment Planning Systems
    Chi, Z.
    Wang, L.
    Chen, L.
    Fan, J.
    Jin, L.
    Ma, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Comparison of two commercial treatment planning systems for IMRT
    Petrie, M
    Robar, JL
    Clark, BG
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1944 - 1944
  • [4] A comparison of two commercial IMRT treatment planning systems
    D'Souza, W
    Sarfaraz, M
    Naqvi, S
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1486 - 1486
  • [5] Systematic comparison of IMRT modules in commercial treatment planning systems
    de Langen, M
    Vieira, S
    Seppenwoolde, Y
    Geelen, B
    Storchi, P
    Heijmen, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S41 - S41
  • [6] A comparison of two commercial treatment-planning systems for IMRT
    Petric, M. Peter
    Clark, Brenda G.
    Robar, James L.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03): : 63 - 80
  • [7] On the performances of different IMRT treatment planning systems for selected paediatric cases
    Fogliata, Antonella
    Nicolini, Giorgia
    Alber, Markus
    Asell, Mats
    Clivio, Alessandro
    Dobler, Barbara
    Larsson, Malin
    Lohr, Frank
    Lorenz, Friedlieb
    Muzik, Jan
    Polednik, Martin
    Vanetti, Eugenio
    Wolff, Dirk
    Wyttenbach, Rolf
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2007, 2 (1)
  • [8] On the performances of different IMRT treatment planning systems for selected paediatric cases
    Antonella Fogliata
    Giorgia Nicolini
    Markus Alber
    Mats Åsell
    Alessandro Clivio
    Barbara Dobler
    Malin Larsson
    Frank Lohr
    Friedlieb Lorenz
    Jan Muzik
    Martin Polednik
    Eugenio Vanetti
    Dirk Wolff
    Rolf Wyttenbach
    Luca Cozzi
    [J]. Radiation Oncology, 2
  • [9] Comparison of IMRT Delivery MUs for Three Commercial Treatment Planning Systems for Two Different Delivery Methods Compensator and MLC Imrt
    Cashon, K.
    Warner, C.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [10] Dosimetric comparison of two commercial IMRT planning and delivery systems
    Duan, J
    Fiveash, JB
    Shen, S
    Murshed, H
    Ove, P
    Liengswangwong, V
    [J]. RADIOLOGY, 2001, 221 : 602 - 602