Reproducibility of bone mineral density measurement in daily practice

被引:70
|
作者
Lodder, MC
Lems, WF
Ader, HJ
Marthinsen, AE
van Coeverden, SCCM
Lips, P
Netelenbos, JC
Dijkmans, BAC
Roos, JC
机构
[1] Vrije Univ Amsterdam, Dept Rheumatol, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Clin Epidemiol & Biostat, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Dept Paediat, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[4] Vrije Univ Amsterdam, Dept Endocrinol, Med Ctr, NL-1007 MB Amsterdam, Netherlands
[5] Vrije Univ Amsterdam, Dept Nucl Med, Med Ctr, NL-1007 MB Amsterdam, Netherlands
关键词
D O I
10.1136/ard.2002.005678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Bone mineral density (BMD) measurements are frequently performed repeatedly for each patient. Subsequent BMD measurements allow reproducibility to be assessed. Objective: To examine the reproducibility of BMD by dual energy x ray absorptiometry (DXA) and to investigate the practical value of different measures of reproducibility in a group of postmenopausal women. Methods: Ninety five women, mean age 59.9 years, underwent two subsequent BMD measurements of spine and hip. Reproducibility was expressed as smallest detectable difference (SDD), coefficient of variation (CV), and intraclass correlation coefficient (ICC). Sources of variation were investigated by multilevel analysis. Results: The median interval between measurements was 0 days ( range 0 - 45). The mean difference (SD) between the measurements (g/cm(2)) was -0.001 (0.02) and -0.0004 (0.02) at L1- 4 and the total hip, respectively. At L1- 4 and the total hip, SDD (g/cm(2)) was +/- 0.05 and +/- 0.04 and CV (%) was 1.92 and 1.59, respectively. The ICC at spine and hip was 0.99. Conclusions: Reproducibility in the postmenopausal women studied was good. In a repeated DXA scan a BMD change exceeding 2root2CV (%), the least significant change (LSC), or the SDD should be regarded as significant. Use of the SDD is preferable to use of the CV and LSC (%) because of its independence from BMD and its expression in absolute units. Expressed as SDD, a BMD change of at least +/- 0.05 g/cm(2) at L1- 4 and +/- 0.04 g/cm(2) at the total hip should be considered significant.
引用
收藏
页码:285 / 289
页数:5
相关论文
共 50 条
  • [1] Measurement of Bone Mineral Density in Daily Practice
    Pfeil, Alexander
    Lehmann, Gabriele
    Boettcher, Joachim
    Reinhardt, Lisa
    Oelzner, Peter
    Wolf, Gunter
    Renz, Diane M.
    AKTUELLE RHEUMATOLOGIE, 2017, 42 (03) : 211 - 216
  • [2] Reproducibility of bone mineral density measurement using dual x-ray absorptiometry in daily clinical practice
    El Maghraoui, A
    Do Santos, AAW
    Jroundi, I
    Nouijal, A
    Ghazi, M
    Achemlal, L
    Bezza, A
    Tazi, MA
    Abouqual, R
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 381 - 381
  • [3] Reproducibility of bone mineral density measurement using dual X-ray absorptiometry in daily clinical practice.
    El Maghraoui, A
    Do Santos, AA
    Jroundi, I
    Nouijai, A
    Ghazi, M
    Achemlal, L
    Bezza, A
    Tazi, MA
    Abouqual, R
    ARTHRITIS AND RHEUMATISM, 2005, 52 (09): : S290 - S290
  • [4] Reproducibility of bone mineral density measurements using dual X-ray absorptiometry in daily clinical practice
    El Maghraoui, A
    Zounon, AAD
    Jroundi, I
    Nouijai, A
    Ghazi, M
    Achemlal, L
    Bezza, A
    Tazi, MA
    Abouqual, R
    OSTEOPOROSIS INTERNATIONAL, 2005, 16 (12) : 1742 - 1748
  • [5] Reproducibility of bone mineral density measurements using dual X-ray absorptiometry in daily clinical practice
    A. El Maghraoui
    A. A. Do Santos Zounon
    I. Jroundi
    A. Nouijai
    M. Ghazi
    L. Achemlal
    A. Bezza
    M. A. Tazi
    R. Abouqual
    Osteoporosis International, 2005, 16 : 1742 - 1748
  • [6] A Study on Method for Improving Reproducibility in the Ultrasonic Measurement of Bone Mineral Density
    Shin, Jeong Sik
    Ahn, Jung Hwan
    Kim, Hwa Young
    Kim, Hyung Jun
    Han, Seung Moo
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2005, 29 (10) : 1430 - 1437
  • [7] Bone mineral density measurement
    Perry, W
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1996, 89 (10) : 599 - 599
  • [8] Measurement of bone mineral density by ultrasound and forearm DXA in clinical practice
    Fait, T.
    Zivny, J.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S207 - S207
  • [9] THE EFFECT OF BISPHOSPHONATES ON BONE MINERAL DENSITY IN PATIENTS WITH ANKYLOSING SPONDYLITIS IN DAILY CLINICAL PRACTICE
    Arends, S.
    Veneberg, J. G.
    Wink, F. R.
    Bos, R.
    Brouwer, E.
    Van der Veer, E.
    Bootsma, H.
    van Roon, E. N.
    Maas, F.
    Spoorenberg, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2016, 75 : 821 - 822
  • [10] The effect of bone mineral density (BMD) measurement of hip bilateral in clinical practice
    Lopes, J. B.
    Danilevicius, C. F.
    Calarbo, V. F.
    Takayama, L.
    Pereira, R. M.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 : S298 - S298