Test beam performance of the CDF Plug Upgrade Hadron Calorimeter

被引:0
|
作者
de Barbaro, P [1 ]
机构
[1] Univ Rochester, Dept Phys & Astron, Rochester, NY 14627 USA
关键词
D O I
暂无
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report on the performance of the CDF End Plug Hadron Calorimeter in a test beam. The sampling calorimeter is constructed using 2 inch iron absorber plates and scintillator planes with wavelength shifting fibers for readout. The linearity and energy resolution of the calorimeter response to pions, and the transverse uniformity of the response to muons and pions are presented. The parameter elh, representing the ratio of the electromagnetic to hadronic response, is extracted from the data.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 50 条
  • [1] Test beam performance of CDF Plug Upgrade EM Calorimeter
    Fukui, Y
    SCIFI 97: CONFERENCE ON SCINTILLATING FIBER DETECTORS, 1998, 450 : 414 - 419
  • [2] Test beam results from the CDF plug upgrade calorimeter
    Apollinari, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 547 - 553
  • [3] Test beam results from the CDF plug upgrade calorimeter
    Apollinari, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 409 (1-3): : 547 - 553
  • [4] The CDF plug upgrade electromagnetic calorimeter: test beam results
    Albrow, M
    Aota, S
    Apollinari, G
    Asakawa, T
    Bailey, M
    de Barbaro, P
    Barnes, V
    Biery, K
    Bodek, A
    Breccia, L
    Brunetti, R
    Budd, H
    Cauz, D
    Demortier, L
    Fiori, I
    Frautschi, M
    Fukui, Y
    Ganel, O
    Gotra, Y
    Hahn, S
    Handa, T
    Hatakeyama, K
    Ikeda, H
    Introzzi, G
    Iwai, J
    Kikuchi, T
    Kim, SH
    Kowald, W
    Laasanen, A
    Lamoureux, J
    Lindgren, M
    Liu, J
    Lusin, S
    Melese, P
    Minato, H
    Murgia, S
    Nakada, H
    Patrick, J
    Pauletta, G
    Sakumoto, W
    Santi, L
    Seiya, Y
    Solodsky, A
    Wigmans, R
    Zucchelli, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3): : 524 - 546
  • [5] A preshower detector for the CDF Plug Upgrade:: test beam results
    Albrow, M
    Aota, S
    Apollinari, G
    Asakawa, T
    Bailey, M
    de Barbaro, P
    Barnes, V
    Benjamin, D
    Biery, K
    Blusk, S
    Bodek, A
    Bolla, G
    Breccia, L
    Brunetti, R
    Budd, H
    Cauz, D
    Demortier, L
    Fiori, I
    Frautschi, M
    Fukui, Y
    Ganel, O
    Gotra, Y
    Hahn, S
    Handa, T
    Hatakeyama, K
    Ikeda, H
    Introzzi, G
    Iwai, J
    Kikuchi, T
    Kim, SH
    Köngeter, A
    Kowald, W
    Laasanen, A
    Lamoureux, J
    Lindgren, M
    Liu, J
    Melese, P
    Minato, H
    Murgia, S
    Nakada, H
    Patrick, J
    Pauletta, G
    Sakumoto, W
    Santi, L
    Seiya, Y
    Solodsky, A
    Spiegel, L
    Thomas, T
    Vilar, R
    Walsh, AM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (1-2): : 104 - 111
  • [6] CDF END PLUG HADRON CALORIMETER UPGRADE - DESIGN, PRODUCTION AND QUALITY-CONTROL RESULTS
    DEBARBARO, P
    BODEK, A
    BUDD, HS
    FAN, Q
    KIM, BJ
    MICHAUD, K
    OLSSON, M
    PILLAI, M
    SAKUMOTO, WK
    ALBROW, M
    BOSSERT, R
    DELCHAMPS, S
    EWALD, K
    FREEMAN, J
    KERBY, J
    KOSKA, W
    LIMON, PJ
    NOBREGA, F
    STRAIT, J
    BROMBERG, C
    HUSTON, J
    MANSOUR, JP
    MILLER, R
    RICHARDS, R
    YOSEF, C
    BARNES, V
    FAHLING, M
    LAASANEN, A
    ROSS, J
    SHEN, Q
    UCHIDA, T
    SUZUKI, J
    IWAI, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 510 - 517
  • [7] Shower maximum detector for the CDF plug upgrade calorimeter
    Apollinari, G.
    Goulianos, K.
    Melese, P.
    Lindgren, M.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 412 (2-3): : 515 - 526
  • [8] Shower maximum detector for the CDF plug upgrade calorimeter
    Apollinari, G
    Goulianos, K
    Melese, P
    Lindgren, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (2-3): : 515 - 526
  • [9] Testbeam results for the CDF End Plug Hadron Calorimeter
    Liu, JB
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 237 - 240
  • [10] Evaluation of candidate photomultiplier tubes for the upgrade of the CDF end plug calorimeter
    Koska, W
    Delchamps, SW
    Kinney, W
    Lewis, DC
    Limon, PJ
    Ronzhin, A
    Strait, J
    Fiori, I
    Gallinaro, M
    Pischalnikov, Y
    Shen, Q
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (01): : 103 - 116