A short biodegradable helical spiral ureteric stent provides better antireflux and drainage properties than a double-J stent

被引:25
|
作者
Lumiaho, Juha [1 ]
Heino, Antero [1 ]
Aaltomaa, Sirpa [1 ]
Valimaa, Tero [3 ]
Talja, Martti [2 ]
机构
[1] Kuopio Univ Hosp, Dept Surg, SF-70210 Kuopio, Finland
[2] Paijat Hame Cent Hosp, Dept Surg, Lahti, Finland
[3] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
来源
关键词
Biodegradable; partial ureteric stent; urography; vesicoureteral reflux; VESICOURETERAL REFLUX; URINE FLOW; PROTOTYPE; INVITRO; DESIGN; INVIVO;
D O I
10.3109/00365599.2010.544673
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective. The use of ureteric stents is a standard treatment for the relief of ureter blockages for benign or malignant reasons. The most common stent design in clinical use is a double-J stent with coiled ends to avoid stent displacement. However, there are a number of complications associated with stent use. A double-J stent design bypasses the ureterovesical junction, enables bladder pressure reflection to the renal pelvis and causes vesicoureteral reflux (VUR). This may result in scarring and renal failure. Material and methods. An animal model was used to investigate whether VUR can be avoided in stented ureters using a short biodegradable partial helical spiral stent design that leaves the ureterovesical junction intact. Materials and methods. Eight female pigs were used. Ureters on the left side were stented using a short helical spiral SR-PLGA stent (group A) and ureters on the right side using double-J stents (group B). Simulated voiding cystoureterography and standard intravenous urography examinations were performed on all eight animals at 4 weeks and on the remaining four animals at 8 weeks. Results. An SR-PLGA single coiled partial stent demonstrated superior drainage properties to a double-J stent at 4 weeks (p == 0.020). A marked but not statistically significant difference in favour of a SR-PLGA stent was also observed at 8 weeks (p == 0.102). A statistically significant difference was observed in VCUG findings in favour of group A at immediate postoperative control as well as in the 4 and 8 week follow-up studies (p == 0.011, p == 0.010, p == 0.046, respectively). Conclusion. A self-expandable, SR-PLGA partial ureteric stent presented with superior drainage and antireflux properties compared to a double-J stent. The reflux commonly related to double-J stent use can be minimized by using a partial ureteric stent design.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 27 条
  • [2] Role of Tamsulosin in Improving Double-J Ureteric Stent-Related Symptoms
    Shelbaia, A.
    Elnashar, A.
    AFRICAN JOURNAL OF UROLOGY, 2011, 17 (04) : 111 - 114
  • [3] Design and characterization of a novel braided biodegradable double-J ureteral stent
    Cui, Haipo
    Zhang, Kui
    Gao, Chenguang
    Kang, Yahong
    Jiang, Hongyan
    POLYMERS FOR ADVANCED TECHNOLOGIES, 2022, 33 (08) : 2519 - 2527
  • [4] NEOPLASIC OBSTRUCTION OF THE URETER - DRAINAGE BY PERCUTANEOUS NEPHROSTOMY OR DOUBLE-J STENT
    DESPORTES, L
    BLANCHET, P
    BENOIT, G
    LECOUTURIER, S
    LANGLOYS, J
    DECAUX, A
    DIPALMA, M
    RICHARD, C
    PRESSE MEDICALE, 1995, 24 (29): : 1332 - 1336
  • [5] Double-J ureteric stent encrustations: Clinical study on crystal formation on polyurethane stents
    Robert, M
    Boularan, AM
    ElSandid, M
    Grasset, D
    UROLOGIA INTERNATIONALIS, 1997, 58 (02) : 100 - 104
  • [6] Evaluation of pain perception associated with use of the magnetic-end ureteric double-J stent for short-term ureteric stenting
    S. Sevcenco
    K. Eredics
    L. Lusuardi
    Hans Christoph Klingler
    World Journal of Urology, 2018, 36 : 475 - 479
  • [7] Impact of Double-J Ureteric Stent in Kidney Transplantation: Single-Center Experience
    Giakoustidis, D.
    Diplaris, K.
    Antoniadis, N.
    Papagianis, A.
    Ouzounidis, N.
    Fouzas, I.
    Vrochides, D.
    Kardasis, D.
    Tsoulfas, G.
    Giakoustidis, A.
    Miserlis, G.
    Imvrios, G.
    Papanikolaou, V.
    Takoudas, D.
    TRANSPLANTATION PROCEEDINGS, 2008, 40 (09) : 3173 - 3175
  • [8] Evaluation of pain perception associated with use of the magnetic-end ureteric double-J stent for short-term ureteric stenting
    Sevcenco, S.
    Eredics, K.
    Lusuardi, L.
    Klingler, Hans Christoph
    WORLD JOURNAL OF UROLOGY, 2018, 36 (03) : 475 - 479
  • [9] Comparison of a biodegradable ureteral stent versus the traditional double-J stent for the treatment of ureteral injury: an experimental study
    Fu, Wei-Jun
    Wang, Zhong-Xin
    Li, Gang
    Cui, Fu-Zhai
    Zhang, Yuanyuan
    Zhang, Xu
    BIOMEDICAL MATERIALS, 2012, 7 (06)
  • [10] Placement of double-J ureteric stent using the pull-through technique in patients with tight ureteric stenosis
    Byung Moon Kim
    Sung Il Park