In Situ Calibration of Light Sensors for Long-Term Monitoring of Vegetation

被引:13
|
作者
Jin, Hongxiao [1 ]
Eklundh, Lars [1 ]
机构
[1] Lund Univ, Fac Sci, Dept Phys Geog & Ecosyst Sci, S-22362 Lund, Sweden
来源
关键词
Calibration; error propagation; fraction of absorbed photosynthetically active radiation (FPAR); light sensor; near-surface remote sensing; Normalized Difference Vegetation Index (NDVI); reflectance; uncertainty; vegetation monitoring; NDVI MEASUREMENTS; SATELLITE DATA; DIFFERENT BIOMES; REFLECTANCE; PHENOLOGY; INDEX; NETWORK; MODIS; PHOTODIODE; RADIATION;
D O I
10.1109/TGRS.2014.2375381
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Light sensors are increasingly used to monitor vegetation growing status by measuring reflectance or transmittance in multispectral or photosynthetically active radiation (PAR) bands. The measurements are then used to estimate vegetation indices or the fraction of absorbed PAR (FPAR) in a continuous and long-term manner and to serve as inputs to environmental monitoring and calibration/validation data for satellite remote sensing. However, light-sensor calibration is often overlooked or not properly attended to, which leads to difficulties when comparing the measurement results across sites and through time. In this paper, we investigate a practical and accurate user-level in situ calibration method in daylight. The calibration of a sensor pair is made for measuring either bihemispherical reflectance or hemispherical-conical reflectance, which are the two most common ground-based spectral measurements. Procedures and considerations are suggested for user calibration. We also provide a method for calibrating and measuring a single-sensor reflectance-derived Normalized Difference Vegetation Index (NDVI) from red and near-infrared bands. The calibration error propagation is analyzed, and the induced uncertainties in vegetation reflectance and in the NDVI are evaluated. The analysis and field measurements show that the NDVI estimated from a user calibration factor can be as accurate as, or even more accurate than, the manufacturer's calibration. The in situ calibration described here remedies the situation where reflectance for large field-of-view sensors cannot be always estimated from the manufacturer's calibration. The method developed in this paper may help improve the reliability of long-term field spectral measurements and contributes to the near-surface remote sensing of vegetation.
引用
收藏
页码:3405 / 3416
页数:12
相关论文
共 50 条
  • [1] In-situ Calibration Of MEMS Inertial Sensors For Long-term Reliability
    Nadig, Sachin
    Lal, Amit
    [J]. 2018 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM (IRPS), 2018,
  • [2] Sensors for long-term construction monitoring
    Slowik, V
    Klink, T
    Krummbach, R
    [J]. GESA-SYMPOSIUM 2001: SICHERHEIT UND ZUVERLASSIGKEIT DURCH EXPERIMENTELLE STRUKTUR-UND BEANSPRUCHUNGSANALYSE, 2001, 1599 : 135 - 140
  • [3] Long-term In Vivo Monitoring of Chemicals with Fiber Sensors
    Jiajia Wang
    Liyuan Wang
    Jianyou Feng
    Chengqiang Tang
    Xuemei Sun
    Huisheng Peng
    [J]. Advanced Fiber Materials, 2021, 3 : 47 - 58
  • [4] Long-term In Vivo Monitoring of Chemicals with Fiber Sensors
    Wang, Jiajia
    Wang, Liyuan
    Feng, Jianyou
    Tang, Chengqiang
    Sun, Xuemei
    Peng, Huisheng
    [J]. ADVANCED FIBER MATERIALS, 2021, 3 (01) : 47 - 58
  • [5] A long-term in situ calibration system for chemistry analysis of seawater
    William E.SEYFRIED Jr.
    [J]. Journal of Zhejiang University-Science A(Applied Physics & Engineering), 2010, 11 (09) : 701 - 708
  • [6] A long-term in situ calibration system for chemistry analysis of seawater
    Chun-yang Tan
    Bo Jin
    Kang Ding
    William E. Seyfried
    Ying Chen
    [J]. Journal of Zhejiang University-SCIENCE A, 2010, 11 : 701 - 708
  • [7] A long-term in situ calibration system for chemistry analysis of seawater
    Tan, Chun-yang
    Jin, Bo
    Ding, Kang
    Seyfried, William E., Jr.
    Chen, Ying
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2010, 11 (09): : 701 - 708
  • [8] In situ analyzers and samplers for long-term oceanographic monitoring
    Jannasch, H
    Sakamoto, C
    Chapin, T
    Johnson, K
    Wheat, G
    [J]. OCEAN COMMUNITY CONFERENCE'98: CELEBRATING 1998 INTERNATIONAL YEAR OF THE OCEAN, PROCEEDINGS VOLS 1 AND 2, 1998, : 504 - 507
  • [9] In situ long-term monitoring system for radioactive contaminants
    Klein, D. M.
    Yukihara, E. G.
    McKeever, S. W. S.
    Durham, J. S.
    Akselrod, M. S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 421 - 424
  • [10] Cross-calibration of MODIS with ETM plus and ALI sensors for long-term monitoring of land surface processes
    Meyer, David
    Chander, Gyanesh
    [J]. EARTH OBSERVING SYSTEMS XI, 2006, 6296