Integrated ratiometric fluorescence probe-based acoustofluidic platform for visual detection of anthrax biomarker

被引:27
|
作者
Wu, Jiafeng [1 ]
Chen, Panpan [1 ]
Chen, Jie [1 ]
Ye, Xiangxue [1 ]
Cao, Shurui [1 ]
Sun, Chuqiang [1 ]
Jin, Yang [1 ]
Zhang, Liying [1 ]
Du, Shuhu [1 ]
机构
[1] Nanjing Med Univ, Sch Pharm, Nanjing 211166, Jiangsu, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Acoustofluidics; Integrated ratiometric fluorescence probe; Anthrax biomarker; Visual detection; Dipicolinic acid; INHALATIONAL ANTHRAX; SENSITIVE DETECTION; SENSOR; MICROPARTICLES; ACID; GENE; SERS;
D O I
10.1016/j.bios.2022.114538
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The sensitive detection of dipicolinic acid (DPA) as an excellent biomarker of Bacillus anthracis, especially through visual point-of-care testing, is significant for accurate and rapid diagnosis of anthrax to timely prevent anthrax disease or biological terrorist attack. Herein, an acoustofluidics-based colorimetric platform with the integrated ratiometric fluorescence probe (INT-probe) was fabricated, which improved the sensitivity of visual detection for DPA and overcame the poor reproducibility of the existing acoustofluidics-assisted colorimetric analysis. For the design of INT-probe, Eu3+-EDTA complex as sensing moiety was grafted onto the surface of blue organosilane-functionalized carbon dots (SiCDs)-doped SiO2 nanoparticles (NPs). Upon exposure to DPA, Eu3+ was sensitized by DPA to emit red luminescence, while the SiCDs as reference inside the SiO2 NPs still kept the blue fluorescence unchanged. Attributed to the acoustic radiation force-driven enrichment of the INT-probe, slight color changes caused by low concentration of DPA could be amplified and distinguished by naked-eyes/ smartphone. With the increase of DPA concentration, obvious color variations of INT-probe/DPA aggregates from blue to pink could be observed, and the color information of the fluorescent aggregates was converted to red, green and blue values for quantitative analysis, whose lowest detectable concentration reached 100 nM that is about 2-3 orders of magnitude lower than the infectious dosage of Bacillus anthracis spores (60 mu M). Impor-tantly, benefiting from the great color signal enhancement by acoustofluidic sensing platform, the usage of Eu3+ reduced to as low as 0.273 mu mol per gram of SiO2 NPs, providing a meaningful way to utilize lanthanide resource efficiently.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Smartphone-integrated ratiometric fluorescence sensing platform based on bimetallic metal-organic framework nanowires for anthrax biomarker detection
    Wang, Ting
    Zhang, Jieyuan
    Wu, Yue
    Wang, Shiyi
    Jiang, Xinhui
    Zhang, Zhengwei
    Li, Siqiao
    MICROCHIMICA ACTA, 2023, 190 (12)
  • [2] A lanthanide metal organic frameworks ratiometric fluorescence sensor for visual detection of anthrax biomarker
    Zhang, Hao
    Hao, Jvxin
    Wang, Runnan
    Meng, Fanxu
    TALANTA, 2025, 288
  • [3] Ratiometric fluorescence sensor based on bimetallic organic frameworks for anthrax biomarker detection
    Zheng, Limin
    Zhang, Jiarong
    Gao, Jie
    He, Fusheng
    Yang, Siqian
    He, Hua
    Dramou, Pierre
    Xiao, Deli
    BIOSENSORS & BIOELECTRONICS, 2025, 278
  • [4] Construction of lanthanide-containing ratiometric probe for facile anthrax biomarker detection
    Liu, Xiao
    Qiu, Yu
    Li, Bin
    Li, Zhiqiang
    Zhang, Ying
    Wang, Jing
    Xiong, Qingqing
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 240
  • [5] The Detection of Anthrax Biomarker DPA by Ratiometric Fluorescence Probe of Carbon Quantum Dots and Europium Hybrid Material Based on Poly(ionic)-Liquid
    Zhang, Dongliang
    Jia, Dongsheng
    Fang, Zhou
    Min, Hua
    Xu, Xiaoyi
    Li, Ying
    MOLECULES, 2023, 28 (18):
  • [6] Terbium Functionalized Micelle Nanoprobe for Ratiometric Fluorescence Detection of Anthrax Spore Biomarker
    Luan, Ke
    Meng, Ruiqian
    Shan, Changfu
    Cao, Jing
    Jia, Jianguo
    Liu, Weisheng
    Tang, Yu
    ANALYTICAL CHEMISTRY, 2018, 90 (05) : 3600 - 3607
  • [7] A novel core-shell lanthanide coordination polymer ratiometric fluorescent probe for the ultrasensitive and visual detection of anthrax biomarker
    Shen, Ping
    Tao, Jingyun
    Gu, Qingyang
    Sun, Jia
    Er, Xinyu
    Jin, Haibo
    MICROCHEMICAL JOURNAL, 2024, 201
  • [8] Ratiometric fluorescence detection of anthrax biomarker based on terbium (III) functionalized graphitic carbon nitride nanosheets
    Ma, Yue-Yang
    Wang, Zi-Jian
    Qian, Dong-Jin
    TALANTA, 2021, 230
  • [9] A ratiometric fluorescence visual test paper for an anthrax biomarker based on functionalized manganese-doped carbon dots
    Rong, Mingcong
    Liang, Yucong
    Zhao, Danli
    Chen, Baiji
    Pan, Chen
    Deng, Xiangzhou
    Chen, Yibo
    He, Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 498 - 505
  • [10] A highly selective lanthanide-containing probe for ratiometric luminescence detection of an anthrax biomarker
    Liu, Xiao
    Li, Bin
    Xu, Yang
    Li, Zhiqiang
    Zhang, Ying
    Ding, Zhi-Jun
    Cui, Hui
    Wang, Jing
    Hou, Hong-Biao
    Li, Huanrong
    DALTON TRANSACTIONS, 2019, 48 (22) : 7714 - 7719