Distal femoral cortical hypertrophy after hip arthroplasty using a cementless double-tapered femoral stem

被引:21
|
作者
Cho, Yoon Je [1 ]
Chun, Young Soo [1 ]
Rhyu, Kee Hyung [1 ]
Baek, Jong Hun [1 ]
Liang, Hu [1 ]
机构
[1] Kyung Hee Univ, Dept Orthopaed Surg, Coll Med, Seoul, South Korea
来源
JOURNAL OF ORTHOPAEDIC SURGERY | 2016年 / 24卷 / 03期
关键词
arthroplasty; replacement; hip; bone remodeling; femur; hemiarthroplasty; THIGH PAIN; FOLLOW-UP; STRAIN DISTRIBUTION; BONE; REPLACEMENT; PROSTHESIS; COMPONENT; STIFFNESS; FIXATION; 2-YEAR;
D O I
10.1177/1602400309
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To review 437 hips in 404 patients who underwent total hip arthroplasty (THA) or hemiarthroplasty using the Accolade TMZF stem to determine the incidence and risk factors of distal femoral cortical hypertrophy (DFCH). Methods. Records of 437 hips in 169 men and 235 women aged 26 to 100 (mean, 65.7) years who underwent THA (n=293) or hemiarthroplasty (n=144) using the Accolade TMZF femoral stem by 2 senior surgeons and were followed up for a mean of 54.7 months were reviewed. Clinical outcome was assessed using the modified Harris Hip Score and visual analogue score for pain. Proximal femoral geometry and canal flare index were assessed on preoperative radiographs, and DFCH, stem position, subsidence, loosening, and stress shielding were assessed on postoperative radiographs according to the Gruen zone. Results. Of 437 hips, 27 (6.2%) developed DFCH and 410 did not. Hips with DFCH had a higher incidence of thigh pain (18.5% vs. 2.2%, p<0.001) and earlier onset of thigh pain (12.3 vs. 20.8 months, p=0.015), compared with those without. Nonetheless, all femoral stems were well-fixed, and no osteolysis or loosening was detected. The 2 groups achieved comparable clinical outcome in terms of Harris Hip Score and pain. The mean canal flare index was higher in hips with than without DFCH (3.706 vs. 3.294, p=0.002). The mean vertical subsidence of the femoral stem was lower in hips with than without DFCH (1.5 vs. 3.4 mm p<0.001). Subsidence negatively correlated with the canal flare index (correlation coefficient= -0.110, p=0.022). The incidence of the DFCH increased with each unit of increment in canal flare index (odds ratio [OR]=1.828, p=0.043) and each year younger in age (OR=0.968, p=0.015). Conclusion. The incidence of DFCH in hips with the Accolade TMZF stem was 6.2%. Patients with a higher canal flare index and younger age had a higher incidence of DFCH. Nonetheless, DFCH did not affect clinical outcome or femoral stem stability.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [1] Total hip arthroplasty for acute femoral neck fractures using a cementless tapered femoral stem
    Klein, Gregg R.
    Parvizi, Javad
    Vegari, David N.
    Rothman, Richard H.
    Purtill, James J.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (08): : 1134 - 1140
  • [2] Does femoral morphology and stem alignment influence outcomes of cementless total hip arthroplasty with proximally coated double-tapered titanium stems?
    Narayanan, Rajkishen
    Elbuluk, Ameer M.
    Chen, Kevin K.
    Eftekhary, Nima
    Zuckerman, Joseph D.
    Deshmukh, Ajit J.
    HIP INTERNATIONAL, 2021, 31 (03) : 354 - 361
  • [3] Does Osteoporosis Increase Early Subsidence of Cement less Double-Tapered Femoral Stem in Hip Arthroplasty?
    Rhyu, Kee Hyung
    Lee, Se Min
    Chun, Young Soo
    Kim, Kang Il
    Cho, Yoon Je
    Yoo, Myung Chul
    JOURNAL OF ARTHROPLASTY, 2012, 27 (07): : 1305 - 1309
  • [4] Cementless Tapered Femoral Stems for Total Hip Arthroplasty in Octogenarians
    Riley, Stephanie A.
    Spears, James R.
    Smith, Langan S.
    Mont, Michael A.
    Elmallah, Randa K.
    Cherian, Jeffrey J.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12): : 2810 - 2813
  • [5] Tapered design for the cementless total hip arthroplasty femoral component
    Mallory, TH
    Head, WC
    Lombardi, AV
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (344) : 172 - 178
  • [6] Higher femoral anteversion restoration accuracy after total hip arthroplasty with a proximally fixed anatomic stem than with a generic straight double-tapered stem
    Sariali, Elhadi
    Moussellard, Hugues Pascal
    HIP INTERNATIONAL, 2023, 33 (04) : 583 - 589
  • [7] Occult periprosthetic femoral fractures occur frequently during a long, trapezoidal, double-tapered cementless femoral stem fixation in primary THA
    Yun, Ho Hyun
    Lim, Jung Taek
    Yang, Se-Hyun
    Park, Phil Sun
    PLOS ONE, 2019, 14 (09):
  • [8] The effect of flexion alignment in total hip arthroplasty with a cementless tapered-wedge femoral stem
    Yoshitani J.
    Kabata T.
    Kajino Y.
    Takagi T.
    Ohmori T.
    Ueno T.
    Ueoka K.
    Tsuchiya H.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1625 - 1632
  • [9] The effects of patient characteristics and stem alignment on distal femoral cortical hypertrophy after cemented polished tapered stem implantation
    Toshiki Iwase
    Daigo Morita
    Genta Takemoto
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 559 - 567
  • [10] The effects of patient characteristics and stem alignment on distal femoral cortical hypertrophy after cemented polished tapered stem implantation
    Iwase, Toshiki
    Morita, Daigo
    Takemoto, Genta
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (04): : 559 - 567