Repeatability and Variability of Myocardial Perfusion Imaging Techniques in Mice: Comparison of Arterial Spin Labeling and First-Pass Contrast-Enhanced MRI

被引:14
|
作者
Naresh, Nivedita K. [1 ]
Chen, Xiao [1 ]
Moran, Eric [1 ]
Tian, Yikui [2 ]
French, Brent A. [1 ]
Epstein, Frederick H. [1 ,3 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
[2] Univ Virginia, Dept Surg, Charlottesville, VA USA
[3] Univ Virginia, Dept Radiol, Charlottesville, VA USA
关键词
myocardial perfusion imaging; cardiac MRI; mouse; ASL; first-pass MRI; CORONARY CIRCULATORY FUNCTION; MAGNETIC-RESONANCE; GAMMA-VARIATE; BLOOD-FLOW; DIABETES-MELLITUS; HEART; MODEL; DYSFUNCTION; VALIDATION; DISPERSION;
D O I
10.1002/mrm.25769
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Preclinical imaging of myocardial blood flow (MBF) can elucidate molecular mechanisms underlying cardiovascular disease. We compared the repeatability and variability of two methods, first-pass MRI and arterial spin labeling (ASL), for imaging MBF in mice. Methods: Quantitative perfusion MRI in mice was performed using both methods at rest, with a vasodilator, and one day after myocardial infarction. Image quality (score of 1-5; 5 best), between-session coefficient of variability (CVbs), intra-user coefficient of variability (CVintra-user), and inter-user coefficient of variability (CVinter-user) were assessed. Acquisition time was 1-2 min for first-pass MRI and approximately 40 min for ASL. Results: Image quality was higher for ASL (3.94 +/- 0.09 versus 2.88 +/- 0.10; P<0.05). Infarct zone CVbs was lower with first-pass (17 +/- 3% versus 46 +/- 9%; P<0.05). The stress perfusion CVintra-user was lower for ASL (3 +/- 1% versus 14 +/- 3%; P<0.05). The stress perfusion CVinter-user was lower for ASL (4 +/- 1% versus 17 +/- 4%; P<0.05). Conclusion: For low MBF conditions such as infarct, first-pass MRI is preferred due to better repeatability and variability. At high MBF such as at vasodilation, ASL may be more suitable due to superior image quality and lower user variability. First-pass MRI has a substantial speed advantage. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:2394 / 2405
页数:12
相关论文
共 50 条
  • [1] Comparison of arterial spin labeling and first-pass dynamic contrast-enhanced MR imaging in the assessment of pulmonary perfusion in humans: The inflow spin-tracer saturation effect
    Lin, YR
    Wu, MT
    Huang, TY
    Tsai, SY
    Chung, HW
    Mai, VM
    Chen, CY
    Pan, HB
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1291 - 1301
  • [2] First-Pass Contrast-Enhanced Myocardial Perfusion MRI in Mice on a 3-T Clinical MR Scanner
    Makowski, Marcus
    Jansen, Christian
    Webb, Ian
    Chiribiri, Amedeo
    Nagel, Eike
    Botnar, Rene
    Kozerke, Sebastian
    Plein, Sven
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1592 - 1598
  • [3] First-pass Contrast-enhanced Myocardial Perfusion MR Imaging in Mice on a 3 Tesla Clinical MR Scanner
    Marcus, Makowski
    Jansen, Christian
    Webb, Ian
    Botnar, Rene
    Kozerke, Sebastian
    Nagel, Eike
    Plein, Sven
    CIRCULATION, 2010, 122 (21)
  • [4] Diagnostic accuracy of stress first-pass contrast-enhanced myocardial perfusion MRI compared with stress myocardial perfusion scintigraphy
    Sakuma, H
    Suzawa, N
    Ichikawa, Y
    Makino, K
    Hirano, T
    Kitagawa, K
    Takeda, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) : 95 - 102
  • [5] Nasopharyngeal carcinoma perfusion MRI Comparison of arterial spin labeling and dynamic contrast-enhanced MRI
    Xiao, Bohan
    Wang, Peiguo
    Zhao, Yingru
    Liu, Ying
    Ye, Zhaoxiang
    MEDICINE, 2020, 99 (22) : E20503
  • [6] Quantification of Renal Perfusion: Comparison of Arterial Spin Labeling and Dynamic Contrast-Enhanced MRI
    Winter, Jeff D.
    St Lawrence, Keith S.
    Cheng, Hai-Ling Margaret
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 608 - 615
  • [7] Contrast-enhanced first-pass myocardial perfusion magnetic resonance Imaging with parallel acquisition at 3.0 tesla
    Ruan, Chun
    Yang, Scott H.
    Cusi, Kenneth
    Gao, Feng
    Clarke, Geoffrey D.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 352 - 360
  • [8] A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging
    Cullen, JHS
    Horsfield, MA
    Reek, CR
    Cherryman, GR
    Barnett, DB
    Samani, NJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) : 1386 - 1394
  • [9] Quantitative Contrast-Enhanced First-Pass Cardiac Perfusion MRI at 3 Tesla With Accurate Arterial Input Function and Myocardial Wall Enhancement
    Breton, Elodie
    Kim, Daniel
    Chung, Sohae
    Axel, Leon
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 676 - 684
  • [10] First-pass contrast-enhanced myocardial perfusion MRI using a maximum up-slope parametric map
    Ruan, Chun
    Yang, Scott
    Clarke, Geoffrey D.
    Amurao, Maxwell R.
    Partyka, Scott R.
    Bradley, Yong C.
    Cusi, Kenneth