Evaluation of high dose volumetric CT to reduce inter-observer delineation variability and PTV margins for prostate cancer radiotherapy

被引:17
|
作者
Alasti, Hamideh [1 ,2 ]
Cho, Young-Bin [1 ,2 ]
Catton, Charles [1 ,2 ]
Berlin, Alejandro [1 ,2 ]
Chung, Peter [1 ,2 ]
Bayley, Andrew [1 ,2 ]
Vandermeer, Aaron [5 ]
Kong, Vickie [1 ,2 ]
Jaffray, David [1 ,2 ,3 ,4 ]
机构
[1] Univ Hlth Network, Princess Margaret Hosp, Radiat Med Program, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[5] RS McLaughlin Durham Reg Canc Ctr, Oshawa, ON, Canada
关键词
Prostate radiotherapy; CT image quality enhancement; Inter-observer variability; CT and MR comparison; Planning target margin; INTENSITY-MODULATED RADIOTHERAPY; CONFORMAL RADIATION-THERAPY; SEMINAL-VESICLES; FIDUCIAL MARKERS; TARGET VOLUME; MRI; TRIAL; LOCALIZATION; IRRADIATION; DEFINITION;
D O I
10.1016/j.radonc.2017.08.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim was to determine whether the enhanced soft tissue contrast provided by high-dose volumetric CT (HDVCT) can reduce inter-observer variability in delineating prostate compared to helical conventional CT (CCT) scans and 3T MRI scans for patients undergoing radical prostate cancer radiotherapy. Secondly, to quantify the potential PTV reduction with decreased inter-observer variability. Materials and methods: A 320 slice volumetric CT scanner was used. The wide-detector coverage of 16 cm enabled volumetric image acquisition of prostate gland in one rotation. Three imaging studies were performed on ten patients. CCT and HDVCT were performed consecutively at the same coordinate system followed by MRI. Five radiation oncologists delineated the prostate. Results: The inter-observer variability is 2.0 +/- 0.6, 1.9 +/- 0.4 and 1.8 +/- 0.4 mm for CCT, HDVCT and MR respectively with the maximum at the apex region. Comparing inter-observer difference variability between CCT and HDVCT with MR indicates that observers have larger variations in contouring using CCT than HDVCT especially at apex. Jaccard index of HDVCT is significantly higher than CCT with a mean difference of 0.03 (p = 0.011). Both MRI and HDVCT provide the opportunity for a 2 mm PTV margin reduction at the apex compared to CCT. Conclusion: Inter-observer variability in delineation remains an important source of systematic error. HDCTV for treatment planning reduces this error without recourse to MRI and permits a PTV reduction of 2 mm at the apex. The margins required to account for residual error with any imaging modality are still greater than are used in typical current practice. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [1] PTV Margin Reduction by High Dose Volumetric CT Scan for Radiotherapy of Prostate Cancer
    Cho, Y.
    Alasti, H.
    Kong, V.
    Charles, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E402 - E403
  • [2] Inter-observer variability of manual contour delineation of structures in CT
    Joskowicz, Leo
    Cohen, D.
    Caplan, N.
    Sosna, J.
    EUROPEAN RADIOLOGY, 2019, 29 (03) : 1391 - 1399
  • [3] Inter-observer variability of manual contour delineation of structures in CT
    Leo Joskowicz
    D. Cohen
    N. Caplan
    J. Sosna
    European Radiology, 2019, 29 : 1391 - 1399
  • [4] Estimating a Delineation Uncertainty Margin to Account for Inter-observer Variability in Breast Cancer Radiotherapy
    Holloway, L. C.
    Jameson, M. G.
    Batumalai, V.
    Koh, E.
    Papadatos, G.
    Lonergan, D.
    Delaney, G. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S741 - S741
  • [5] Inter-observer variability in target delineation for brain metastases in stereotactic radiotherapy
    Di Biase, S.
    Patani, F.
    Fasciolo, D.
    Rosa, C.
    Di Carlo, C.
    Allajbej, A.
    Gasparini, L.
    Delli Pizzi, A.
    Trignani, M.
    Caravatta, L.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S682 - S682
  • [6] Inter-observer variability in OAR and target volume delineation in curative prostate cancer patients
    Tiigi, K.
    Tiigi, R.
    Oro, I.
    Adamson, M.
    Kolk, K.
    Poldveer, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [7] Evaluation of inter-observer variability of bladder boundary delineation on cone-beam CT
    Nishioka, Kentaro
    Shimizu, Shinichi
    Kinoshita, Rumiko
    Inoue, Tetsuya
    Onodera, Shunsuke
    Yasuda, Koichi
    Harada, Keiichi
    Nishikawa, Yukiko
    Onimaru, Rikiya
    Shirato, Hiroki
    RADIATION ONCOLOGY, 2013, 8
  • [8] Evaluation of inter-observer variability of bladder boundary delineation on cone-beam CT
    Kentaro Nishioka
    Shinichi Shimizu
    Rumiko Kinoshita
    Tetsuya Inoue
    Shunsuke Onodera
    Koichi Yasuda
    Keiichi Harada
    Yukiko Nishikawa
    Rikiya Onimaru
    Hiroki Shirato
    Radiation Oncology, 8
  • [9] x Inter-observer variability of intestinal loops delineation after whole pelvis radiotherapy for prostate patients
    Sacco, V.
    Sini, C.
    Perna, L.
    Deantoni, C.
    Chiorda, B. Noris
    Fiorino, C.
    Cozzarini, C.
    Salvadori, G.
    Calandrino, R.
    Di Muzio, N.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S892 - S892
  • [10] A review of interventions to reduce inter-observer variability in volume delineation in radiation oncology
    Vinod, Shalini K.
    Min, Myo
    Jameson, Michael G.
    Holloway, Lois C.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (03) : 393 - 406