Investigation on liquid film of urea-water solutions with diode laser absorption spectroscopy

被引:8
|
作者
Yang, Huinan [1 ,2 ]
Guo, Xiaolong [1 ,2 ]
Zhou, Wu [1 ,2 ]
Chen, Benting [1 ,2 ]
Hu, Jiarui [1 ,2 ]
Su, Mingxu [1 ,2 ]
Cai, Xiaoshu [1 ,2 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Univ Shanghai Sci & Technol, Shanghai Key Lab Multiphase Flow & Heat Transfer, Shanghai 200093, Peoples R China
关键词
AQUEOUS-SOLUTION; THICKNESS; TEMPERATURE; FLOW;
D O I
10.1007/s00348-015-1941-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Measurement of multiparameter of liquid films (e.g., film thickness and concentration) is very important to understand the film formation processes in industrial applications. Here, a novel diode laser absorption spectroscopy (DLAS) sensor was developed to simultaneously measure the liquid film thickness and concentration of urea-water solutions by forming the transmittance ratio at two wave-number positions. The performance of the sensor employed two diode lasers (6613.25 and 7187.50 cm(-1)) was first validated using a calibration tool providing liquid film of urea-water solutions with known film thickness (100-1000 mu m) and mass fractions (5-50 wt%), and then, the sensor was applied to study a free-falling film of urea-water solutions on a vertical transparent quartz plate. Shadowgraph images were simultaneously taken as a means to obtain falling film thickness, and it was observed that measured film thickness was in good agreement with DLAS method and shadowgraph technique, and the deviation between these two techniques was 4.1 % when the falling film was stable.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Investigation on liquid film of urea–water solutions with diode laser absorption spectroscopy
    Huinan Yang
    Xiaolong Guo
    Wu Zhou
    Benting Chen
    Jiarui Hu
    Mingxu Su
    Xiaoshu Cai
    Experiments in Fluids, 2015, 56
  • [2] Measurement of the Evaporating Liquid Film of a Urea-Water Solution Using Diode Laser Absorption Spectroscopy
    Yang, H-N.
    Guo, X-L.
    Su, M-X.
    Cai, X-S.
    LASERS IN ENGINEERING, 2016, 35 (5-6) : 351 - 358
  • [3] Measurement of liquid water film thickness on opaque surface with diode laser absorption spectroscopy
    Yang, Huinan
    Wei, Wu
    Su, Mingxu
    Chen, Jun
    Cai, Xiaoshu
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 60 : 110 - 114
  • [4] Liquid structure of the urea-water system studied by dielectric spectroscopy
    Hayashi, Yoshihito
    Katsumoto, Yoichi
    Omori, Shinji
    Kishii, Noriyuki
    Yasuda, Akio
    JOURNAL OF PHYSICAL CHEMISTRY B, 2007, 111 (05): : 1076 - 1080
  • [5] Urea and urea-water solutions-an infrared study
    Grdadolnik, J
    Maréchal, Y
    JOURNAL OF MOLECULAR STRUCTURE, 2002, 615 (1-3) : 177 - 189
  • [6] Investigation into falling film outside horizontal tube based on diode laser absorption spectroscopy
    Yang, Huinan
    Jiang, Yong
    Guo, Yufeng
    Li, Ling
    Su, Mingxu
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (01)
  • [7] Hydrogen from urea-water and ammonia-water solutions
    Rollinson, Andrew N.
    Rickett, Gavin L.
    Lea-Langton, Amanda
    Dupont, Valerie
    Twigg, Martyn V.
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2011, 106 (3-4) : 304 - 315
  • [8] Multiparameter Determination of Thin Liquid Urea-Water Films
    van der Kley, Sani
    Goet, Gabriele
    Schmidt, Anna
    Einspieler, Valentina
    Wagner, Steven
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [9] Laser diagnostics for urea-water solution spray characterization
    Kapusta, Lukasz Jan
    Teodorczyk, Andrzej
    VII INTERNATIONAL CONGRESS ON COMBUSTION ENGINES, 2017, 118
  • [10] Simultaneous measurement of film thickness, temperature, and mass fraction of urea-water-solutions by multi-wavelength laser absorption spectroscopy
    Yang, Huinan
    Shi, Jianwei
    Su, Mingxu
    Wu, Wei
    Cai, Xiaoshu
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (05):