Characterizing Short-Lived Protein Folding Intermediates by Top-Down Hydrogen Exchange Mass Spectrometry

被引:71
|
作者
Pan, Jingxi [1 ]
Han, Jun [2 ]
Borchers, Christoph H. [2 ]
Konermann, Lars [1 ]
机构
[1] Univ Western Ontario, Dept Chem, London, ON N6A 5B7, Canada
[2] Univ Victoria, Genome BC Prote Ctr, Victoria, BC V8Z 7X8, Canada
基金
加拿大创新基金会;
关键词
ELECTRON-CAPTURE DISSOCIATION; ION-CYCLOTRON RESONANCE; HYDROGEN/DEUTERIUM EXCHANGE; STRUCTURAL-CHARACTERIZATION; MOLTEN GLOBULE; CYTOCHROME-C; INTRAMOLECULAR MIGRATION; APOMYOGLOBIN; KINETICS; DYNAMICS;
D O I
10.1021/ac101679j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work combines pulsed hydrogen/deuterium exchange (HDX) and top-down mass spectrometry for the structural characterization of short-lived protein folding intermediates. A custom-built flow device with three sequential mixing steps is used for (i) triggering protein folding, (ii) pulsed D2O labeling, and (iii) acid quenching. The earliest folding time point that can be studied with this system is 10 ms. The mixing device was coupled online to the electrospray source of a Fourier transform mass spectrometer, where intact protein ions are fragmented by electron capture dissociation (ECD). The viability of this experimental strategy is demonstrated by applying it to the refolding of horse apo-myoglobin (aMb), a reaction known to involve a transient intermediate. Cooling of the mixing device to 0 C reduces the reaction rate such that the folding process occurs within the experimentally accessible time window. Top-down ECD provides an average spatial resolution of ca. 2 residues, surpassing the resolution typically achieved in traditional proteolytic digestion/HDX studies. Amide back exchange is virtually eliminated by the short (similar to 1 s) duration of the acid quenching step. The aMb folding intermediate exhibits HDX protection in helices G and H, whereas the remainder of the protein is largely unfolded. Marginal protection is seen for helix A. Overall, the top-down ECD approach used here offers insights into the sequence of events leading from the unfolded state to the native conformation, with envisioned future applications in the areas of protein misfolding and aggregation. The time-resolved experiments reported herein represent an extension of our previous work, where HDX/MS with top-down ECD was employed for monitoring "static" protein structures under equilibrium conditions (Pan et al. J. Am. Chem. Soc. 2009, 131, 12801).
引用
收藏
页码:8591 / 8597
页数:7
相关论文
共 50 条
  • [1] Hydrogen/Deuterium Exchange Mass Spectrometry with Top-Down Electron Capture Dissociation for Characterizing Structural Transitions of a 17 kDa Protein
    Pan, Jingxi
    Han, Jun
    Borchers, Christoph H.
    Konermann, Lars
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (35) : 12801 - 12808
  • [2] Protein Structural Characterization by Hydrogen/Deuterium Exchange Mass Spectrometry with Top-down Electron Capture Dissociation
    Yu, Hai Dong
    Ahn, Seonghee
    Kim, Byungjoo
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (05) : 1401 - 1406
  • [3] Using mass spectrometry to identify short-lived electrochemical reaction intermediates
    Zare, Richard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [4] Top-down mass spectrometry
    Doerr A.
    Nature Methods, 2008, 5 (1) : 24 - 24
  • [5] Short-Lived α-Helical Intermediates in the Folding of β-Sheet Proteins
    Chen, Eefei
    Everett, Mary Lou
    Holzknecht, Zoie E.
    Holzknecht, Robert A.
    Lin, Shu S.
    Bowles, Dawn E.
    Parker, William
    BIOCHEMISTRY, 2010, 49 (26) : 5609 - 5619
  • [6] Conformer-specific characterization of nonnative protein states using hydrogen exchange and top-down mass spectrometry
    Wang, Guanbo
    Abzalimov, Rinat R.
    Bobst, Cedric E.
    Kaltashov, Igor A.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (50) : 20087 - 20092
  • [7] Intact protein mass spectrometry and top-down proteomics
    Whitelegge, Julian
    EXPERT REVIEW OF PROTEOMICS, 2013, 10 (02) : 127 - 129
  • [8] Strategies for Top-Down Hydrogen Deuterium Exchange-Mass Spectrometry: A Mini Review and Perspective
    Langford, Joel B.
    Ahmed, Elizabeth
    Fang, Mulin
    Cupp-Sutton, Kellye
    Smith, Kenneth
    Wu, Si
    JOURNAL OF MASS SPECTROMETRY, 2024, 59 (11):
  • [9] Decoding protein modifications using top-down mass spectrometry
    Nertila Siuti
    Neil L Kelleher
    Nature Methods, 2007, 4 : 817 - 821
  • [10] Decoding protein modifications using top-down mass spectrometry
    Siuti, Nertila
    Kelleher, Neil L.
    NATURE METHODS, 2007, 4 (10) : 817 - 821