摘要
Objectives-To assess the feasibility and reproducibility of fetal thy-box visualization and to set normative data for the fetal thymus using this technique. Methods-We performed a cross-sectional observational study in pregnant women in their second trimester of pregnancy who attended the fetal medicine unit of the Hospital Gregorio Maranon from March 2011 to March 2013. Using thy-box sonography, which sets boundaries within the thymus, we assessed the feasibility of the thy-box and analyzed the factors related to its visualization. Measurements of the thy-box anteroposterior and transverse diameters were performed in healthy fetuses. Interobserver agreement was studied for both items. We set normative data for the thy-box diameters in singleton and twin pregnancies. Results-A total of 337 patients from 15 to 37 weeks were recruited after exclusion criteria. Thy-box feasibility was 74.2% (250 of 337). Nonfeasible cases were related to the fetal anterior spine and advanced gestational age. Assessment of the thy-box anteroposterior and transverse diameters was achievable in 250 fetuses. Interobserver agreement was good for feasibility and measurements (kappa = 0.80). Linear growth of the thy-box in both diameters was observed in relation to gestational age during the second half of pregnancy. Thy-box diameters did not show significant differences according to the type of gestation, fetal sex, or chorionicity. Conclusions-Thy-box diameters are achievable and reproducible by sonography in normal singleton and twin pregnancies during the second trimester; however, although feasible, the thy-box transverse diameter measurement is not reliable beyond 28 weeks. Further studies are needed to evaluate thy-box diameters in pathologic cases, especially conotruncal anomalies.
引用
收藏
页码:853 / 858
页数:6
相关论文
共 17 条
  • [1] Nomogram of Fetal Thymus Using Thy-Box Technique in South Indian Population
    Kandasamy, Subapriya
    Raj, Sherina Paul
    JOURNAL OF FETAL MEDICINE, 2018, 5 (02) : 69 - 73
  • [2] Sonographic Evaluation of the Fetal Thymus Using the Thy-Box Technique Between 13 and 16 Weeks' Gestation
    Weissmann-Brenner, Alina
    Zemet, Roni
    Kivilevitch, Zvi
    Zalel, Yaron
    JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (12) : 2263 - 2268
  • [3] How to identify the thymus in the fetus: the thy-box
    Paladini, D.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2011, 37 (04) : 488 - 492
  • [4] Sonographic assessment of a suspected biloma: A case report and review of the literature
    Tana, Claudio
    D'Alessandro, Patrizio
    Tartaro, Armando
    Tana, Marco
    Mezzetti, Andrea
    Schiavone, Cosima
    WORLD JOURNAL OF RADIOLOGY, 2013, 5 (05): : 220 - 225
  • [5] A Literature Review of Assessment What New Sonographic Faculty Should Know
    Curry, Reva A.
    Gonzalez-DeJesus, Naydeen T.
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2010, 26 (02) : 97 - 105
  • [6] MR Assessment of Normal Fetal Lung Volumes: A Literature Review
    Deshmukh, Swati
    Rubesova, Erika
    Barth, Richard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (02) : W212 - W217
  • [7] SONOGRAPHIC ASSESSMENT OF INTIMA-MEDIA THICKNESS OF CAROTID ARTERIES- A REVIEW OF LITERATURE
    Kanwal, Hafiza Iqra
    Shahid, Munaza
    Bacha, Raham
    PAKISTAN HEART JOURNAL, 2022, 55 (03): : 207 - 212
  • [8] Logistic models and artificial intelligence in the sonographic assessment of adnexal masses - a systematic review of the literature
    Grigore, Mihaela
    Popovici, Razvan Mihai
    Gafitanu, Dumitru
    Himiniuc, Loredana
    Murarasu, Mara
    Micu, Romeo
    MEDICAL ULTRASONOGRAPHY, 2020, 22 (04) : 469 - 475
  • [9] Sonographic assessment of inflammatory bowel disease in the emergency department: A case series and review of the literature
    Esterson, Akiva
    Alpert, Evan Avraham
    Gabrieli, Selma
    Granat, Nadav
    JOURNAL OF CLINICAL ULTRASOUND, 2021, 49 (03) : 277 - 281
  • [10] Fetal hepatic artery flow assessment in prenatal diagnostics - a review of the literature
    Lipa, Michal
    Samaha, Robert B. B.
    Borowski, Dariusz
    Wielgos, Miroslaw
    Wegrzyn, Piotr
    GINEKOLOGIA POLSKA, 2014, 85 (07) : 532 - 535