Robust design of an active micro-mixer based on the Taguchi method

被引:20
|
作者
Park, Jae-Yong [2 ]
Kim, Yong-Dae [2 ]
Kim, Sang-Rak [2 ]
Han, Seog-Young [1 ]
Maeng, Joo-Sung [1 ]
机构
[1] Hanyang Univ, Sch Mech Engn, Seoul 133791, South Korea
[2] Hanyang Univ, Grad Sch, Dept Engn Mech, Seoul 133791, South Korea
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2008年 / 129卷 / 02期
关键词
micro-mixer; design of experiment; Taguchi method; robust design; lattice Boltzmann method;
D O I
10.1016/j.snb.2007.09.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microfluidic analysis of an active micro-mixer with an oscillating stirrer in a straight micro-channel was performed. The effects of molecular diffusion and disturbance by the stirrer for mixing were examined. The mixing was calculated by the lattice Boltzmann method using the D2Q9 model. In this study, the time-averaged mixing index was used to estimate the mixing performance of time-dependent flow. From the results, it was found that the mixer with an oscillating stirrer was much more enhanced and stabilized. Therefore, an optimum design for an active micro-mixer with an oscillating stirrer was performed based on the Taguchi method in order to obtain a robust solution. The design parameters were selected as the reduced frequency, the length and the rotation angle of the stirrer, and the optimal values were determined as 2, 0.8 D and +/- 75 degrees, respectively. It was found that the mixing index of the optimal design was improved by up to 84.59% compared to that of the initial design. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:790 / 798
页数:9
相关论文
共 50 条
  • [1] Optimum Design of an Active Micro-mixer Using Successive Kriging Method
    Ryu, Su-Pil
    Park, Jae-Yong
    Han, Seog-Young
    [J]. INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2011, 12 (05) : 849 - 855
  • [2] Optimum design of an active micro-mixer using successive Kriging method
    Su-Pil Ryu
    Jae-Yong Park
    Seog-Young Han
    [J]. International Journal of Precision Engineering and Manufacturing, 2011, 12 : 849 - 855
  • [3] Optimum design of an active micro-mixer using the Kriging metamodel
    Park, J. Y.
    Yu, J. S.
    Im, M. K.
    Oh, Y. K.
    Park, J. Y.
    Kim, Y. D.
    Maeng, J. S.
    Han, S. Y.
    [J]. EVALUATION, INSPECTION AND MONITORING OF STRUCTURAL INTEGRITY, 2008, : 85 - 90
  • [4] A scalable active micro-mixer for biomedical applications
    Luca Cortelezzi
    Simone Ferrari
    Gabriele Dubini
    [J]. Microfluidics and Nanofluidics, 2017, 21
  • [5] A scalable active micro-mixer for biomedical applications
    Cortelezzi, Luca
    Ferrari, Simone
    Dubini, Gabriele
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2017, 21 (03)
  • [6] A novel micro-mixer with a quasi-active rotor: fabrication and design improvement
    Kim, Yongdae
    Lee, Jongkwang
    Kwon, Sejin
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (10)
  • [7] Optimum design of a dynamic micro-mixer for multiphase flow
    Han, S. Y.
    Park, J. Y.
    Kim, Y. D.
    An, S. J.
    Maeng, J. S.
    [J]. PROGRESSES IN FRACTURE AND STRENGTH OF MATERIALS AND STRUCTURES, 1-4, 2007, 353-358 : 2836 - +
  • [8] Design and Simulation of Microfluidic Micro-Mixer with Parallelogram Barriers
    Dusa, Arpad
    Podunavac, Ivana
    Kojic, Sanja
    Radonic, Vasa
    [J]. PROCEEDINGS OF 18TH INTERNATIONAL CONFERENCE ON SMART TECHNOLOGIES (IEEE EUROCON 2019), 2019,
  • [9] Optimization of the Micro-Mixer with an Oscillating Stirrer using the Kriging Method
    Park, J. Y.
    Yoo, J. S.
    Lee, W. G.
    Kim, Y. D.
    Maeng, J. S.
    Han, S. Y.
    [J]. 4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 723 - +
  • [10] Optimized design of droplet micro-mixer with sinusoidal structure based on Pareto genetic algorithm
    Yu, Qing
    Chen, Xueye
    Li, Xiaoyu
    Zhang, Dengying
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 135