Quantitative angiography of coronary artery dimensions 24 hours after rotational atherectomy

被引:1
|
作者
Reisman, M
Buchbinder, M
Harms, V
McDaniel, M
Peterson, KL
机构
[1] Swedish Med Ctr, Seattle, WA USA
[2] Sharp Mem Hosp, San Diego, CA USA
[3] Univ Calif San Diego, San Diego, CA 92103 USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1998年 / 81卷 / 12期
关键词
D O I
10.1016/S0002-9149(98)00201-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rotational atherectomy results in platelet activation and heat generation, which may impact artery size immediately after treatment. In addition, arteries treated with balloon angioplasty may exhibit recoil within 24 hours. In this study, arteries treated with rotational atherectomy, with and without adjunctive balloon angioplasty, were analyzed by quantitative coronary angiography to determine the effect of rotational atherectomy on the dynamic behavior of the arterial wall within 24 hours after the procedure. Quantitative coronary angiography was performed at a core laboratory. Coronary angiogram acquisitions were preceded by intracoronary nitroglycerin injections and were repeated using identical angles of projection. Proximal and distal reference vessel diameters were 2.55 +/- 0.60 and 2.28 +/- 0.51 mm, respectively, and did not change from pre-to postprocedure. Both were larger the following day increasing to 2.72 +/- 0.65 and 2.52 +/- 0.52 mm, respectively, (p<0.001). Minimum luminal diameter (MLD) increased from 0.70 +/- 0.28 mm before to 1.49 +/- 0.34 mm after the procedure and to 1.72 +/- 0.37 mm at 24-hour follow-up (p<0.001). Subset analysis of patients treated with rotational atherectomy alone or rotational atherectomy with adjunctive balloon angioplasty revealed that the increase in luminal diameters occurred in both subsets. Patients treated with adjunctive angioplasty had a smaller initial MLD, a larger postprocedure MLD, and no difference in MLD at 24-hour follow-up compared with stand-alone rotational atherectomy. Subset analysis of 100 patients who had 6-month follow-up angiography revealed that both a calculated acute gain and chronic late loss, based on a 24-hour film, differed significantly from values using a film acquired immediately after the procedure. However, the slope of the linear regression between acute gain and chronic late loss did not differ. Coronary arteries treated with rotational atherectomy with or without adjunctive balloon angioplasty increase significantly in size during the first 24 hours after the procedure. This phenomenon has implications for the calculation of absolute gain and chronic late loss, but not for the linear relation between the 2 quantitative outcomes. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:1427 / 1432
页数:6
相关论文
共 50 条
  • [1] REPEAT CORONARY ANGIOGRAPHY AT 24 HOURS FOLLOWING SUCCESSFUL ROTATIONAL AND DIRECTIONAL ATHERECTOMY
    CORCOS, T
    FAVEREAU, X
    ZIMARINO, M
    TAMBURINO, C
    TOUSSAINT, M
    GUERIN, Y
    EIFERMAN, C
    SOUFFRANT, G
    [J]. CIRCULATION, 1993, 88 (04) : 547 - 547
  • [2] QUANTITATIVE ANGIOGRAPHY AFTER DIRECTIONAL CORONARY ATHERECTOMY
    SERRUYS, PW
    UMANS, VAWM
    STRAUSS, BH
    VANSUYLEN, RJ
    VANDENBRAND, M
    SURYAPRANATA, H
    DEFEYTER, PJ
    ROELANDT, J
    [J]. BRITISH HEART JOURNAL, 1991, 66 (02): : 122 - 129
  • [3] Left main coronary artery perforation after rotational atherectomy
    Jurado-Roman, Alfonso
    Galeote, Guillermo
    Jimenez-Valero, Santiago
    Ofelia Rosillo, Sandra
    Moreno, Raul
    Lopez-Sendon, Jose Luis
    [J]. REC-INTERVENTIONAL CARDIOLOGY, 2021, 3 (01): : 78 - 79
  • [4] CORONARY ANGIOGRAPHY AFTER FIBRINOLYTIC THERAPY - IS IT USEFUL AFTER 24 HOURS?
    Baptista, A.
    Ferreira, C.
    Magalhaes, P.
    Leao, S.
    Mateus, P.
    Moreira, I.
    [J]. CARDIOLOGY, 2013, 126 : 274 - 274
  • [5] Quantitative coronary dimensions and restenosis after directional atherectomy or balloon angioplasty
    Garratt, KN
    Rogers, PJ
    Vlietstra, RE
    Kaufman, UP
    Grill, DE
    Bailey, KR
    Chesebro, JH
    Holmes, DR
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1996, 9 (02) : 121 - 127
  • [6] CLINICAL, ANGIOGRAPHIC AND PROCEDURAL CORRELATES OF QUANTITATIVE CORONARY DIMENSIONS AFTER DIRECTIONAL CORONARY ATHERECTOMY
    POPMA, JJ
    DECESARE, NB
    ELLIS, SG
    HOLMES, DR
    PINKERTON, CA
    WHITLOW, P
    KING, SB
    GHAZZAL, ZMB
    TOPOL, EJ
    GARRATT, KN
    KEREIAKES, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (05) : 1183 - 1189
  • [7] Coronary Pseudoaneurysm After Transluminal Coronary Rotational Atherectomy
    Wu, Wei
    Wang, Yining
    Zhang, Shuyang
    Shen, Zhunjun
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S141 - S143
  • [8] PREDICTORS OF IMPROVEMENT IN QUANTITATIVE CORONARY DIMENSIONS FOLLOWING CORONARY ATHERECTOMY
    POPMA, JJ
    DECESARE, NB
    GHAZZAL, ZMB
    PINKERTON, CA
    GARRATT, KN
    [J]. CIRCULATION, 1990, 82 (04) : 311 - 311
  • [9] Coronary artery perforation associated with rotational atherectomy.
    Matsubara, T
    Murata, A
    Kawajiri, K
    Sano, K
    Toriyama, T
    Kawahara, H
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (5A): : 105G - 105G
  • [10] Percutaneous transluminal rotational atherectomy for coronary artery disease
    Wasiak, Jason
    Law, Janette
    Watson, Paul
    Spinks, Anneliese
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (12):