The Calculation Method of the Inductance for Three-Phase Air Reactors

被引:0
|
作者
Zheng Liping [1 ]
Yang Botao [1 ]
机构
[1] Xian Univ Technol, Inst Automat, Xian, Shaanxi, Peoples R China
关键词
air reactor: three-phase; inductance;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the design of air core reactors, the inductance calculation is an important technical parameter. Because air core reactors usually work in the three-phase condition, in this paper, the calculation method of the inductance of three-phase air reactors is obtained by using the method of equal division. Firstly, the magnetic flux, the induced potential and the self inductance and mutual inductance of the single-phase air reactor can be calculated accurately by using the method of equal division, Then, the division of different methods was taken according to the structure characteristics of three-phase reactors, and the calculation method of the mutual inductance between coils can be worked out for the three-phase air reactor in the different arrangements. This method is high accurate, simple and practical. The calculation example was given.
引用
收藏
页码:432 / 436
页数:5
相关论文
共 50 条
  • [1] Calculation of Zero Sequence Inductance of a Three-Phase Reactor
    Akpinar, Eyup
    Selici, Dilara
    2017 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2017, : 111 - 115
  • [2] Three-phase catalytic reactors
    Biardi, G
    Baldi, G
    CATALYSIS TODAY, 1999, 52 (2-3) : 223 - 234
  • [3] Three-phase airlift reactors
    Kawalec-Pietrenko, BE
    INZYNIERIA CHEMICZNA I PROCESOWA, 2004, 25 (03): : 1925 - 1935
  • [4] Comparative Analysis of Three-Phase and Single-Phase Inductance Measurements of the Three-Phase Inductor
    Puskarczyk, Magdalena
    Jez, Radoslaw
    Ruszczyk, Adam
    Buze, Andrzej
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [5] Nonlinear hydrodynamics of three-phase reactors
    Yano, T
    Kikuchi, R
    Tsutsumi, A
    Yoshida, K
    Puncochár, M
    Drahos, J
    KAGAKU KOGAKU RONBUNSHU, 1999, 25 (04) : 530 - 534
  • [6] Identification of permanent faults for three-phase autoreclosing using inductance parameter on transmission lines with shunt reactors
    Qiao, Zhanjun
    Fan, Wenbo
    International Journal of Smart Home, 2013, 7 (05): : 197 - 206
  • [7] Drift flux distribution parameter in three-phase air-lift reactors
    Popovic, M. K.
    Wulfes, C.
    Bajpai, R. K.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2007, 21 (04) : 435 - 437
  • [8] Drift flux distribution parameter in three-phase air-lift reactors
    Department of Biotechnology, FB-V, Technische Fachhochschule - Berlin, Seestraße 64, 13347 Berlin, Germany
    不详
    Chem Biochem Eng Q, 2007, 4 (435-437):
  • [9] Application of an accurate calculation method for dual three-phase PMSM
    Keller, Daniel
    Karayel, Akif
    Parspour, Nejila
    2021 IEEE WORKSHOP ON ELECTRICAL MACHINES DESIGN, CONTROL AND DIAGNOSIS (WEMDCD), 2021, : 34 - 39
  • [10] Decoupling Control Method of Asymmetric Dual Three-Phase PMSM with Mutual Coupling Inductance
    Lim, Gyu Cheol
    Choi, Jonghun
    Noh, Gwangyol
    Han, Yongsu
    Ha, Jung-Ik
    2021 THIRTY-SIXTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2021), 2021, : 2194 - 2199