Light Shift in CPT Based Cs Miniature Atomic Clocks

被引:0
|
作者
Miletic, D. [1 ]
Affolderbach, C. [1 ]
Mileti, G. [1 ]
Hasegawa, M. [2 ]
Gorecki, C. [2 ]
机构
[1] Univ Neuchatel, LTF, CH-2000 Neuchatel, Switzerland
[2] Univ Franche Comte, CNRS, FEMTO ST, UMR 6174, Besancon, France
来源
2011 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM/EUROPEAN FREQUENCY AND TIME FORUM PROCEEDINGS | 2011年
基金
瑞士国家科学基金会;
关键词
VAPOR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on our studies of the light shift in a miniature atomic clock based on Coherent Population Trapping (CPT) in Cesium. There is no data published in the literature on the frequency and intensity-related light shift coefficients for CPT atomic clock on the Cesium D-1 line, only for the D-2 line. With our data we fill this gap and report on the measurements of light shift for the Cs D-1 line in a MEMS buffer-gas cell. The behavior of the light shift due to different laser intensities, laser frequencies and due to different cell temperatures is discussed.
引用
收藏
页码:200 / 202
页数:3
相关论文
共 50 条
  • [1] AC Stark-shift in CPT-based Cs miniature atomic clocks
    D. Miletic
    C. Affolderbach
    M. Hasegawa
    R. Boudot
    C. Gorecki
    G. Mileti
    Applied Physics B, 2012, 109 : 89 - 97
  • [2] AC Stark-shift in CPT-based Cs miniature atomic clocks
    Miletic, D.
    Affolderbach, C.
    Hasegawa, M.
    Boudot, R.
    Gorecki, C.
    Mileti, G.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2012, 109 (01): : 89 - 97
  • [3] Investigation on light shift in CPT-Ramsey resonance for compact atomic clocks
    Yano, Yuichiro
    Gao, Wujie
    Goka, Shigeyoshi
    Kajita, Masatoshi
    2014 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2014, : 291 - 295
  • [4] CPT pulse excitation method based on VCSEL current modulation for miniature atomic clocks
    Ide, Takumi
    Goka, Shigeyoshi
    Yano, Yuichiro
    2015 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & THE EUROPEAN FREQUENCY AND TIME FORUM (FCS), 2015, : 167 - 170
  • [5] Active light shift stabilization in modulated CPT clocks
    Shah, V.
    Schwindt, P. D. D.
    Gerginov, V.
    Knappe, S.
    Hollberg, L.
    Kitching, J.
    PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXPOSITION, VOLS 1 AND 2, 2006, : 699 - +
  • [6] Light shift reduction in atomic clocks
    Affolderbach, C
    Andreeva, C
    Cartaleva, S
    Karaulanov, T
    Mileti, G
    Slavov, D
    EIGHTH INTERNATIONAL CONFERENCE ON LASER AND LASER INFORMATION TECHNOLOGIES, 2003, 5449 : 342 - 349
  • [7] Strategies for reducing the light shift in atomic clocks
    Katori, Hidetoshi
    Ovsiannikov, V. D.
    Marmo, S. I.
    Palchikov, V. G.
    PHYSICAL REVIEW A, 2015, 91 (05):
  • [8] Spectroscopy of micro-fabricated Cs vapours cells for miniature atomic clocks
    Miletic, D.
    Affolderbach, C.
    Mileti, G.
    Hasegawa, M.
    Gorecki, C.
    16TH INTERNATIONAL SCHOOL ON QUANTUM ELECTRONICS: LASER PHYSICS AND APPLICATIONS, 2011, 7747
  • [9] A CPT-Based Miniature Atomic Clock Testbed
    Haji, M.
    Patel, P.
    Donnellan, S.
    Langham, C.
    Gill, P.
    PROCEEDINGS OF THE 2019 JOINT CONFERENCE OF THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EUROPEAN FREQUENCY AND TIME FORUM (EFTF-IFCS 2019), 2019,
  • [10] Characterization of compact CPT Clocks based on a Cs-Ne microcell
    Boudot, R.
    Liu, X.
    Kraemer, E.
    Abbe, P.
    Passilly, N.
    Galliou, S.
    Chutani, R. K.
    Giordano, V.
    Gorecki, C.
    Al-Samaneh, A.
    Wahl, D.
    Michalzik, R.
    2012 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2012, : 79 - 82