Parameters affecting the determination of mercury by anodic stripping voltammetry using a gold electrode

被引:103
|
作者
Giacomino, Agnese [1 ]
Abollino, Omella [1 ]
Malandrino, Mery [1 ]
Mentasti, Edoardo [1 ]
机构
[1] Univ Turin, Dept Analyt Chem, I-10125 Turin, Italy
关键词
mercury; anodic stripping voltammetry; gold electrode; supporting electrolyte; wave form;
D O I
10.1016/j.talanta.2007.11.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical determination of aqueous Hg(II) by anodic stripping voltammetry (ASV) at a solid gold electrode is described. The aim of this work is to optimise all factors that can influence this determination. Potential wave forms (linear sweep, differential pulse, square wave), potential scan parameters. deposition time, deposition potential and surface cleaning procedures were examined for their effect on the mercury peak shape and intensity. Five supporting electrolytes were tested. The best responses were obtained with square wave potential wave form and diluted HCl as supporting electrolyte. Electrochemical and mechanical surface cleaning, aimed at removing the amount of mercury deposited onto the gold surface, were necessary for obtaining a good performance of the electrode. Response linearity, repeatability, accuracy and detection limit were also evaluated. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:266 / 273
页数:8
相关论文
共 50 条
  • [1] Trace determination of mercury by anodic stripping voltammetry at the rotating gold electrode
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    ANALYTICA CHIMICA ACTA, 2000, 424 (01) : 65 - 76
  • [2] Determination of mercury and copper in waste water by anodic-stripping voltammetry at the gold electrode
    Bonfil, Y
    Brand, M
    Kirowa-Eisner, E
    REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 19 (3-4): : 201 - 216
  • [3] Anodic stripping voltammetry for arsenic determination on composite gold electrode
    Navrátil, T
    Kopanica, M
    Krista, J
    CHEMIA ANALITYCZNA, 2003, 48 (02): : 265 - 272
  • [4] Determination of mercury by anodic stripping voltammetry with a gold nanoparticle-modified glassy carbon electrode
    Abollino, Ornella
    Giacomino, Agnese
    Malandrino, Mery
    Piscionieri, Giuseppina
    Mentasti, Edoardo
    ELECTROANALYSIS, 2008, 20 (01) : 75 - 83
  • [5] ANODIC STRIPPING VOLTAMMETRY USING THE HANGING MERCURY DROP ELECTRODE
    DEMARS, RD
    SHAIN, I
    ANALYTICAL CHEMISTRY, 1957, 29 (12) : 1825 - 1827
  • [6] DETERMINATION OF COBALT BY ANODIC-STRIPPING VOLTAMMETRY AT A MERCURY FILM ELECTRODE
    BLOOM, H
    NOLLER, BN
    RICHARDSON, DE
    ANALYTICA CHIMICA ACTA, 1979, 109 (01) : 157 - 160
  • [7] ANODIC STRIPPING VOLTAMMETRY OF MERCURY(2) AT GRAPHITE ELECTRODE
    PERONE, SP
    KRETLOW, WJ
    ANALYTICAL CHEMISTRY, 1965, 37 (8P1) : 968 - &
  • [8] Heated mercury film electrode for anodic stripping voltammetry
    Jasinski, M
    Kirbs, A
    Schmehl, M
    Gründler, P
    ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (01) : 26 - 28
  • [9] Determination of manganese in drinking water by anodic stripping voltammetry at a mercury film electrode
    Panascikaite, Erika
    Armalis, Saulius
    CHEMIJA, 2011, 22 (01): : 41 - 45
  • [10] Determination of gold in copper matrix by anodic stripping voltammetry with gold activated graphite electrode
    Korolczuk, M
    CHEMIA ANALITYCZNA, 1996, 41 (04): : 641 - 646