Modification of an automated liquid-handling system for reagent-jet, nanoliter-level dispensing

被引:11
|
作者
Hicks, JS [1 ]
Harker, BW [1 ]
Beattie, KL [1 ]
Doktycz, MJ [1 ]
机构
[1] Oak Ridge Natl Lab, Div Life Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.2144/01304rr05
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reducing the scale of biochemical reactions is becoming commonplace. Examples include the screening of large libraries of chemical compounds or gene sequences. These applications demand the ability to transfer sub-microliter volumes of fluid. To this end, we have modified a Hamilton(R) MICROLAB(R) 2200 with high-speed solenoids and a liquid pressurization system to modulate volume delivery down to the nanoliter level. Additional modifications include the use of sapphire-tipped dispensing nozzles and a high-resolution substage to assist in the construction of DNA microarrays. Techniques for characterizing the dispensed volume are presented.
引用
收藏
页码:878 / +
页数:7
相关论文
共 8 条
  • [1] Automated Liquid Handling Robots: Bridging the Gap Between Nanoliter Liquid Handling and Larger Volume Dispensing
    Gaisford, Wendy
    AMERICAN LABORATORY, 2013, 45 (03) : 39 - 41
  • [2] A new crop of automated liquid-handling tools - Instruments offer protocol control and precision for low-volume dispensing
    Glaser, V
    GENETIC ENGINEERING NEWS, 2002, 22 (10): : 16 - +
  • [3] Strategies to Maintain Sample Integrity Using a Liquid-Filled Automated Liquid-Handling System with Fixed Pipetting Tips
    Ouyang, Zheng
    Federer, Susi
    Porter, Gregory
    Kaufmann, Christoph
    Jemal, Mohammed
    JALA - Journal of the Association for Laboratory Automation, 2008, 13 (01): : 24 - 32
  • [4] Evaluation of an automated liquid-handling system (Tecan Genesis RSP 100) in the Abbott LCx assay for Chlamydia trachomatis
    Hanson, KL
    Cartwright, CP
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (05) : 1975 - 1977
  • [5] A SEMI-AUTOMATED METHOD FOR THE DETERMINATION OF PEPSIN ACTIVITY IN GASTRIC-JUICE USING THE TECAN LIQUID-HANDLING SYSTEM
    LYNN, AG
    LANE, AC
    SMEATON, LA
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1988, 16 (01) : 26 - 27
  • [6] The Use of a Dual Dye Photometric Calibration Method to Identify Possible Sample Dilution from an Automated Multichannel Liquid-handling System
    Dong, Huijin
    Ouyang, Zheng
    Liu, Jane
    Jemal, Mohammed
    JALA - Journal of the Association for Laboratory Automation, 2006, 11 (02): : 60 - 64
  • [7] The use of a dual dye photometric calibration method to identify possible sample dilution from an automated multichannel liquid-handling system
    Dong, Huijin
    Zheng Ouyang
    Liu, Jane
    Jemal, Mohammed
    CLINICS IN LABORATORY MEDICINE, 2007, 27 (01) : 113 - +
  • [8] Sensitive and Specific Detection of SARS-CoV-2 Antibodies Using a High-Throughput, Fully Automated Liquid-Handling Robotic System
    Karp, Donna Grace
    Cuda, Deanne
    Tandel, Devangkumar
    Danh, Kenneth
    Robinson, Peter V.
    Seftel, David
    Tian, Honglin
    Pandori, Mark
    Miller, Kevin W. P.
    Tsai, Cheng-T.
    SLAS TECHNOLOGY, 2020, 25 (06): : 545 - 552