Mass spectrometric analysis of allergens in roasted walnuts

被引:34
|
作者
Downs, Melanie L. [1 ,2 ,3 ]
Baumert, Joseph L. [1 ]
Taylor, Steve L. [1 ]
Mills, E. N. C. [2 ,3 ]
机构
[1] Univ Nebraska, Dept Food Sci & Technol, Food Allergy Res & Resource Program, Lincoln, NE 68583 USA
[2] Univ Manchester, Ctr Resp Med & Allergy, Resp Inst Inflammat & Repair, Manchester Acad Hlth Sci Ctr, Manchester, Lancs, England
[3] Univ Manchester, Manchester Inst Biotechnol, Manchester, Lancs, England
关键词
Food allergy; Label-free quantification; Protein mass spectrometry; Thermal processing; Tree nut; Walnut; MAJOR FOOD ALLERGEN; JUGLANS-REGIA; IN-VITRO; MAILLARD REACTION; PEANUT PROTEINS; STABILITY; DIGESTION; PRODUCTS; VICILIN; CLONING;
D O I
10.1016/j.jprot.2016.04.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Thermal processing of allergenic foods can induce changes in the foods' constituent allergens, but the effects of heat treatment are poorly defined. Like other commonly allergenic tree nuts, walnuts often undergo heat treatment (e.g. roasting or baking) prior to consumption. This study evaluated the changes in solubility and detect ability of allergens from roasted walnuts using tandem mass spectrometry methods. Walnuts were roasted (132 degrees C or 180 degrees C for 5, 10, or 20 min) and prepared for LC-MS/MS using sequential or simultaneous extraction and tryptic digestion protocols. The LC-MS/MS data analysis incorporated label-free quantification of relevant allergens and Maillard adduct screening. In some proteins (2S albumin, LTP, and the 7S globulin N-terminal region) minor changes in relative abundance were observed following roasting. The mature 7S and 11S globulins, however, showed significantly increased detection following roasting at 180 degrees C for 20 min when using the simultaneous extraction/digestion protocol, possibly due to increased digestibility of the proteins. The results of this study indicate that individual walnut allergens respond differently to thermal processing, and the detection of these proteins by LC-MS/MS is dependent on the protein in question, its susceptibility to proteolytic digestion, the degree of thermal processing, and the sample preparation methodology. Significance: Understanding the behavior of food allergens in the context of relevant food matrices is critical for both food allergen management and for elucidating matrix and processing-associated factors influencing protein allergenicity. The use of mass spectrometry to identify food allergens and detect allergenic food residues has been increasingly developed due to the advantages associated with the direct, sequence-level analysis possible with MS. To date, however, few studies have implemented MS technology to analyze the effects of thermal processing on allergenic food proteins. The MS analysis results presented in this study revealed not only information about the molecular-level effects of roasting on walnut allergens but also data pertinent to the development of MS-based detection methods for walnut residues in food products. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:62 / 69
页数:8
相关论文
共 50 条
  • [1] Mass Spectrometry Analysis on the Breakage of Allergens in High-Molecular-Mass Polymer of Roasted Peanuts
    Song, Min
    Zhang, Ying
    Zhu, Weichao
    Zhou, Wenlong
    Li, Xin
    Yang, Anshu
    Tong, Ping
    Wu, Zhihua
    Chen, Hongbing
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2024, 72 (06) : 3142 - 3149
  • [2] Mass spectrometric analysis of electrophoretically separated allergens and proteases in grass pollen diffusates
    Raftery, MJ
    Saldanha, RG
    Geczy, CL
    Kumar, RK
    RESPIRATORY RESEARCH, 2003, 4 (10)
  • [3] Mass spectrometric analysis of electrophoretically separated allergens and proteases in grass pollen diffusates
    Mark J Raftery
    Rohit G Saldanha
    Carolyn L Geczy
    Rakesh K Kumar
    Respiratory Research, 4
  • [4] Determination of volatile thiols in roasted coffee by derivatization and liquid chromatography-high resolution mass spectrometric analysis
    Vichi, Stefania
    Jeri, Yenny
    Cortes-Francisco, Nuria
    Palacios, Oscar
    Caixach, Josep
    FOOD RESEARCH INTERNATIONAL, 2014, 64 : 610 - 617
  • [5] Proteomic analysis and mass-spectrometric identification of differentially regulated proteins in primary human keratinocytes by allergens
    Ohnesorge, S.
    Dietz, L.
    Pankert, P.
    Schnoelzer, M.
    Thierse, H.
    WIENER KLINISCHE WOCHENSCHRIFT, 2008, 120 : 42 - 42
  • [6] Mass Spectrometric Investigation of Molecular Variability of Grass Pollen Group 1 Allergens
    Fenaille, Francois
    Nony, Emmanuel
    Chabre, Henri
    Lautrette, Aurelie
    Couret, Marie-Noelle
    Batard, Thierry
    Moingeon, Philippe
    Ezan, Eric
    JOURNAL OF PROTEOME RESEARCH, 2009, 8 (08) : 4014 - 4027
  • [7] MASS SPECTROMETRIC ANALYSIS OF GERMANIUM
    HONIG, RE
    ANALYTICAL CHEMISTRY, 1953, 25 (10) : 1530 - 1535
  • [8] Mass spectrometric phosphorylation analysis
    Zeller, M
    König, S
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (04) : 898 - 909
  • [9] MASS SPECTROMETRIC ANALYSIS OF OXYGEN
    BRION, CE
    STEWART, WB
    NATURE, 1968, 217 (5132) : 946 - &
  • [10] AUTOMATIC MASS SPECTROMETRIC ANALYSIS
    DUDENBOSTEL, BF
    PRIESTLEY, W
    ANALYTICAL CHEMISTRY, 1954, 26 (08) : 1275 - 1278