Development of a 3D Anthropomorphic Phantom Generator for Microwave Imaging Applications of the Head and Neck Region

被引:2
|
作者
Pelicano, Ana Catarina [1 ,2 ]
Conceicao, Raquel C. [2 ]
机构
[1] Univ Lisbon, Fac Ciencias, P-1749016 Lisbon, Portugal
[2] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, P-1749016 Lisbon, Portugal
关键词
anthropomorphic phantoms; head and neck modelling; radar-based microwave imaging; cervical lymph nodes; DIELECTRIC-PROPERTIES;
D O I
10.3390/s20072029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of 3D anthropomorphic head and neck phantoms is of crucial and timely importance to explore novel imaging techniques, such as radar-based MicroWave Imaging (MWI), which have the potential to accurately diagnose Cervical Lymph Nodes (CLNs) in a neoadjuvant and non-invasive manner. We are motivated by a significant diagnostic blind-spot regarding mass screening of LNs in the case of head and neck cancer. The timely detection and selective removal of metastatic CLNs will prevent tumor cells from entering the lymphatic and blood systems and metastasizing to other body regions. The present paper describes the developed phantom generator which allows the anthropomorphic modelling of the main biological tissues of the cervical region, including CLNs, as well as their dielectric properties, for a frequency range from 1 to 10 GHz, based on Magnetic Resonance images. The resulting phantoms of varying complexity are well-suited to contribute to all stages of the development of a radar-based MWI device capable of detecting CLNs. Simpler models are essential since complexity could hinder the initial development stages of MWI devices. Besides, the diversity of anthropomorphic phantoms resulting from the developed phantom generator can be explored in other scientific contexts and may be useful to other medical imaging modalities.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Development of an Anthropomorphic Phantom of the Axillary Region for Microwave Imaging Assessment
    Savazzi, Matteo
    Abedi, Soroush
    Istuk, Niko
    Joachimowicz, Nadine
    Roussel, Helene
    Porter, Emily
    O'Halloran, Martin
    Costa, Jorge R.
    Fernandes, Carlos A.
    Felicio, Joao M.
    Conceicao, Raquel C.
    SENSORS, 2020, 20 (17) : 1 - 20
  • [2] 3D Anthropomorphic Phantom Facilitates Accurate Dosimetry for Head and Neck Radiopharmaceutical Therapy Trials
    Adam, D.
    Grudzinski, J.
    Cox, B.
    Marsh, I. R.
    Bradshaw, T.
    Hill, P.
    Harari, P.
    Bednarz, B. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S313 - S313
  • [3] Development and validation of a 3D anthropomorphic phantom for dental CBCT imaging research
    Merken, Karen
    Monnens, Janne
    Marshall, Nicholas
    Johan, Nuyts
    Brasil, Danieli Moura
    Santaella, Gustavo Machado
    Politis, Constantinus
    Jacobs, Reinhilde
    Bosmans, Hilde
    MEDICAL PHYSICS, 2023, 50 (11) : 6714 - 6736
  • [4] Anthropomorphic Calcaneus Phantom for Microwave Bone Imaging Applications
    Amin, Bilal
    Shahzad, Atif
    Kelly, Daniel
    O'Halloran, Martin
    Adnan Elahi, Muhammad
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2021, 5 (03): : 206 - 213
  • [5] Development of a physical 3D anthropomorphic breast phantom
    Carton, Ann-Katherine
    Bakic, Predrag
    Ullberg, Christer
    Derand, Helen
    Maidment, Andrew D. A.
    MEDICAL PHYSICS, 2011, 38 (02) : 891 - 896
  • [6] Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom
    Alzahrani, Meshal
    O'Hara, Christopher
    Bird, David
    Baldwin, Jack P. C.
    Naisbit, Mitchell
    Teh, Irvin
    Broadbent, David A.
    Al-Qaisieh, Bashar
    Johnstone, Emily
    Speight, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (21):
  • [7] Smart Simplification of Anthropomorphic Head Phantom Aimed for Microwave Imaging
    Singh, T.
    Abedi, S.
    Ninkovic, B.
    Stevanovic, M.
    Joachimowicz, N.
    Roussel, H.
    Kolundzija, B.
    2021 15TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2021,
  • [8] Development of Novel Heterogeneous Anthropomorphic Head and Neck Phantom Using 3D Printer for IMRT Patient Specific Quality Assurance
    Kadoya, N.
    Abe, K.
    Nemoto, H.
    Sato, K.
    Ieko, Y.
    Ito, K.
    Takayama, Y.
    Chiba, T.
    Dobashi, S.
    Takeda, K.
    Jingu, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E595 - E595
  • [9] Dual-Material 3D Printing of An Anthropomorphic Head Phantom
    Peters, M.
    Craft, D.
    Baltz, G.
    Followill, D.
    Howell, R.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [10] 3D printed anthropomorphic left ventricular myocardial phantom for nuclear medicine imaging applications
    Janos Kiss
    Laszlo Balkay
    Kornel Kukuts
    Marton Miko
    Attila Forgacs
    Gyorgy Trencsenyi
    Aron K. Krizsan
    EJNMMI Physics, 9