Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation

被引:1
|
作者
Wadeson, Nicola [1 ]
Morton, Edward [2 ]
Lionheart, William [1 ]
机构
[1] Univ Manchester, Sch Math, Manchester, Lancs, England
[2] Rapiscan Syst Ltd, Surrey, England
基金
英国工程与自然科学研究理事会;
关键词
Compton scatter; Rayleigh scatter; Geant4; Monte-Carlo simulation; x-ray CT; RTT; DIFFRACTION;
D O I
10.1117/12.843981
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A high-speed motionless-gantry x-ray CT machine has been designed to allow for 3D images to be collected in real time. By using multiple, switched x-ray sources and fixed detector rings, the time consuming mechanical rotation of conventional CT machines can be removed. However, the nature of this design limits the possibility of detector collimation since each detector must now be able to record the energy of x-ray beams from a number of different directions. The lack of collimation has implications in the reconstructed image due to an increase in the number of scattered photons recorded. A Monte Carlo computer simulation of the x-ray machine has been developed, using the Geant4 software toolkit, to analyse the behaviour of both Rayleigh and Compton scattered photons when considering airport baggage and medical applications. Four different scattering objects were analysed based on 50kVp, 100kVp and 150kVp spectra for a tungsten target. Two suitcase objects, a body and a brain phantom were chosen as objects typical of airport baggage and medical CT. The results indicate that the level of scatter is negligible for a typical airport baggage application, since the majority of space in a suitcase consists of clothing, which has a low density. Scatter contributes to less than 1% of the image in all instances. However, due to the large amounts of water found in the human body, the level of scatter in the medical instances are significantly higher, reaching 37% when the body phantom is analysed at 50kVp.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A Geant4-based Monte Carlo X-ray imaging simulation platform
    Li, Ouyi
    Gao, Jianhua
    Zhang, Qiong
    [J]. APPLIED RADIATION AND ISOTOPES, 2024, 210
  • [2] Monte Carlo study of X-ray grazing incidence microscopy using Geant4
    Li, Wenjie
    Xu, Jie
    Yang, Cheng
    Li, Mingtao
    Wang, Xin
    Zhang, Xing
    Mu, Baozhong
    [J]. OPTICS EXPRESS, 2023, 31 (22) : 35453 - 35470
  • [3] Monte Carlo simulation of scintillation behavior of zinc oxide under X-ray illumination using GEANT4
    Taheri, Ali
    Saramad, Shahyar
    Setayeshi, Saeed
    [J]. RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2013, 168 (02): : 153 - 162
  • [4] X-Ray Coherent Scatter Diffraction Pattern Modeling in GEANT4
    Kapadia, A.
    Samei, E.
    Harrawood, B.
    Sahbaee, P.
    Chawla, A.
    Tan, Z.
    Brady, D.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3642 - 3643
  • [5] A GEANT4 based simulation for pixelated X-ray hybrid detectors
    Marinho, F.
    Akiba, K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 50 - 51
  • [6] GXPS: A Geant4-based Monte Carlo code for x-ray polycapillary simulation
    Chi, Zhijun
    [J]. JOURNAL OF APPLIED PHYSICS, 2020, 128 (12)
  • [7] Validation of the Geant4 Monte Carlo package for X-ray fluorescence spectroscopy in triaxial geometry
    Amaro, Pedro
    Santos, Jose Paulo
    Samouco, Ana
    Adao, Ricardo
    Martins, Luis Souto
    Weber, Sebastian
    Tashenov, Stanislav
    Carvalho, Maria Luisa
    Pessanha, Sofia
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 130 : 60 - 66
  • [8] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [9] Monte Carlo simulation and scatter correction of the GE advance PET scanner with SimSET and geant4
    Barret, O
    Carpenter, TA
    Clark, JC
    Ansorge, RE
    Fryer, TD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20): : 4823 - 4840
  • [10] Geant4 portlet: Monte-Carlo simulation with Geant4 on bwGRiD over a browser-based interface
    Zyl, A.
    Hesser, J.
    Mosch, C.
    Alnewaini, Z.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 168 - 169