Current measurements in a wide dynamic range -: applications in electrochemical nanotechnology

被引:56
|
作者
Meszaros, Gabor [1 ]
Li, Chen
Pobelov, Ilya
Wandlowski, Thomas
机构
[1] Res Ctr Julich, Ctr Nanoelect Syst Informat Technol Cni, Inst Bio & Nanosyst 3, D-52425 Julich, Germany
[2] Hungarian Acad Sci, Chem Res Ctr, Inst Mat & Environm Chem, H-1025 Budapest, Hungary
关键词
D O I
10.1088/0957-4484/18/42/424004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Current measurements in a wide dynamic range from low picoamperes up to a few milliamperes are usually carried by implementing logarithmic current-to-voltage converter circuits. Conductance studies in nanoscale metal vertical bar molecule vertical bar metal junctions require measurements with a high dynamic range, good accuracy and reasonable speed simultaneously. In this work we propose two novel circuit solutions which comply with these conditions: one is based on a high-accuracy, fine-tunable logarithmic current-to-voltage converter. Another circuit implements a double-output (or multiple-output) linear current-to-voltage converter, for which the problem of range-switching has been circumvented. Both circuits were applied in constructing a low-current bipotentiostat dedicated to the electrochemical formation of molecular-scale gaps, and a novel scanning tunnelling microscope preamplifier stage for current-distance spectroscopy studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Wide Dynamic Range Current Mirror
    Cracan, Arcadie
    Bonteanu, Gabriel
    CAS 2018 PROCEEDINGS: 2018 INTERNATIONAL SEMICONDUCTOR CONFERENCE, 2018, : 173 - 176
  • [2] Wide Dynamic Range Multi-Channel Electrochemical Instrument for In-Field Measurements
    Parsnejad, Sina
    Hu, Yaoxing
    Wan, Hao
    Ashoori, Ehsan
    Mason, Andrew J.
    2016 IEEE SENSORS, 2016,
  • [3] Design and implementation of a voltammetry potentiostat with wide dynamic current range measurement for electrochemical biosensors
    Chun-Yueh Huang
    Analog Integrated Circuits and Signal Processing, 2014, 81 : 205 - 214
  • [4] Design and implementation of a voltammetry potentiostat with wide dynamic current range measurement for electrochemical biosensors
    Huang, Chun-Yueh
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2014, 81 (01) : 205 - 214
  • [5] Bias current generators with wide dynamic range
    Delbrück, T
    van Schaik, A
    2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 1, PROCEEDINGS, 2004, : 337 - 340
  • [6] Novel wide dynamic range current mirror
    Sujito
    Huu-Duy Tran
    Wei, You-Cyuan
    Wang, Hung-Yu
    MODERN PHYSICS LETTERS B, 2019, 33 (14-15):
  • [7] Bias current generators with wide dynamic range
    Delbrück, T
    van Schaik, A
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2005, 43 (03) : 247 - 268
  • [8] Bias Current Generators with Wide Dynamic Range
    Tobi Delbrück
    André Van Schaik
    Analog Integrated Circuits and Signal Processing, 2005, 43 : 247 - 268
  • [9] A perfectly current matched charge pump with wide dynamic range for ultra low voltage applications
    Zhong, Dongdong
    Han, Yan
    Sun, Jun
    Zhou, Qian
    Cheung, Ray C. C.
    Sui, Wenquan
    IEICE ELECTRONICS EXPRESS, 2014, 11 (23):
  • [10] Wide Dynamic Range CMOS Pseudo-differential Current Conveyors: CMOS Realizations and Applications
    Mahmoud, Soliman A.
    CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2013, 32 (02) : 477 - 497