Ambient air monitoring around the dioxin remediation site in Da Nang, Vietnam, using passive air samplers

被引:6
|
作者
Sau, Trinh Khac [1 ]
Truong, Nghiem Xuan [2 ]
Hanh, Tran Thi Tuyet [3 ]
Le Hung, Bao [2 ]
Thang, Nguyen Duc [2 ]
Le Lan Anh, Thi [1 ]
机构
[1] Vietnam Russia Trop Ctr, Inst Biomed, 63 Nguyen Huyen, Hanoi, Vietnam
[2] Vietnam Russia Trop Ctr, Dept Chem Environm, 63 Nguyen Huyen, Hanoi, Vietnam
[3] Hanoi Univ Publ Hlth, Dept Environm Hlth, 1A Duc Thang Rd,Duc Thang Ward, Hanoi, Vietnam
关键词
Passive air sampling; PCDDs; PCDFs; Temporal variation; Agent Orange; Health risk; PERSISTENT ORGANIC POLLUTANTS; DIBENZO-P-DIOXINS; POLYCHLORINATED-BIPHENYLS; ORGANOCHLORINE PESTICIDES; INHALATION RISK; HOT-SPOTS; DL-PCB; PCDD/FS; CITY; INDUSTRIAL;
D O I
10.1007/s10661-021-09223-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concentrations and temporal variations of polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDDs/PCDFs) in ambient air between March 2013 and February 2017 were investigated by passive air samplers containing polyurethane foam (PUF) disks in the dioxin remediation area using in-pile thermal desorption (IPTD) technology at Da Nang airport, Vietnam. The PCDD/PCDF concentrations in ambient air at each site depended on the location of the emission sources and the wind direction, the dioxin contamination level of excavated materials, the periods of excavation and transport, and the operation of the IPTD treatment system. The PCDD/PCDF concentrations were the highest in the former Agent Orange mixing and loading area (AOMLA), which was the closest to the IPTD system, with total toxic equivalent (TEQ) values ranging from 0.437 to 15.3 pg/PUF/day. The total TEQ concentrations in the Sen Lake area ranged from 0.138 to 2.41 pg/PUF/day. The lowest concentration of PCDDs/PCDFs occurred in the northern perimeter area, with total TEQ values ranging from 0.164 to 0.972 pg/PUF/day. The decreasing trend of the PCDD/PCDF concentrations in ambient air was confirmed over time at all three monitoring sites, among which there was a strong decrease in the former AOMLA after February 2015. Residents living near the Da Nang airport were at a low risk of being exposed to PCDDs/PCDFs through inhalation during remediation project implementation, while residents living close to the former AOMLA faced elevated risks with an average daily dose of PCDDs/PCDFs through inhalation ranging from 0.017 to 0.82 pg TEQ/kg body weight/day.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Ambient air monitoring around the dioxin remediation site in Da Nang, Vietnam, using passive air samplers
    Trinh Khac Sau
    Nghiem Xuan Truong
    Tran Thi Tuyet Hanh
    Bao Le Hung
    Nguyen Duc Thang
    Thi Le Lan Anh
    Environmental Monitoring and Assessment, 2021, 193
  • [2] Monitoring of tropospheric ozone in the ambient air with passive samplers
    Alejo, Daniellys
    Morales, Mayra C.
    Nunez, Vladimir
    Bencs, Laszlo
    Van Grieken, Rene
    Van Espen, Piet
    MICROCHEMICAL JOURNAL, 2011, 99 (02) : 383 - 387
  • [3] Air Monitoring of Persistent Organic Pollutants Using Passive Air Samplers
    Choi, Sung-Deuk
    Chang, Yoon-Seok
    JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2005, 21 (05) : 481 - 494
  • [4] THE USE OF PASSIVE SAMPLERS FOR MONITORING POLYCYCLIC AROMATIC-HYDROCARBONS IN AMBIENT AIR
    JACOB, J
    GRIMMER, G
    HILDEBRANDT, A
    SCIENCE OF THE TOTAL ENVIRONMENT, 1993, 140 : 307 - 321
  • [5] Effect based monitoring of seasonal ambient air exposures in Australia sampled by PUF passive air samplers
    Kennedy, Karen
    Macova, Miroslava
    Bartkow, Michael E.
    Hawker, Darryl W.
    Zhao, Bin
    Denison, Michael S.
    Mueller, Jochen F.
    ATMOSPHERIC POLLUTION RESEARCH, 2010, 1 (01) : 50 - 58
  • [6] THE USE OF DIFFUSIVE SAMPLERS FOR MONITORING OF AMBIENT AIR
    BROWN, RH
    PURE AND APPLIED CHEMISTRY, 1993, 65 (08) : 1859 - 1874
  • [7] Calibration and Application of PUF Disk Passive Air Samplers To Assess Chlorinated Paraffins in Ambient Air in Australia, China, and Vietnam
    He, Chang
    Thai, Phong K.
    Bertrand, Lidwina
    Jayarathne, Ayomi
    van Mourik, Louise
    Phuc, Dam Hoang
    Banks, Andrew
    Mueller, Jochen F.
    Wang, Xianyu Fisher
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (50) : 21061 - 21070
  • [8] A field intercomparison of three passive air samplers for gaseous mercury in ambient air
    Naccarato, Attilio
    Tassone, Antonella
    Martino, Maria
    Moretti, Sacha
    Macagnano, Antonella
    Zampetti, Emiliano
    Papa, Paolo
    Avossa, Joshua
    Pirrone, Nicola
    Nerentorp, Michelle
    Munthe, John
    Wangberg, Ingvar
    Stupple, Geoff W.
    Mitchell, Carl P. J.
    Martin, Adam R.
    Steffen, Alexandra
    Babi, Diana
    Prestbo, Eric M.
    Sprovieri, Francesca
    Wania, Frank
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (05) : 3657 - 3672
  • [9] Passive samplers for air quality monitoring in a Brazilian university
    Vieira, Leticia Canal
    Korf, Eduardo Pavan
    Brandli, Luciana Londero
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2013, 53 (1-2) : 148 - 158
  • [10] ENVIRONMENTAL MONITORING OF TRITIUM IN AIR WITH PASSIVE DIFFUSION SAMPLERS
    WOOD, MJ
    WORKMAN, WJG
    FUSION TECHNOLOGY, 1992, 21 (02): : 529 - 535