Volatile polar metabolites in exhaled breath condensate (EBC): collection and analysis

被引:27
|
作者
Pleil, Joachim D. [1 ]
Hubbard, Heidi F. [1 ]
Sobus, Jon R. [1 ,2 ]
Sawyer, Keegan [2 ]
Madden, Michael C. [3 ]
机构
[1] US EPA, Human Exposure & Atmospher Sci Div, Natl Exposure Res Lab, Off Res & Dev, Res Triangle Pk, NC 27711 USA
[2] Univ N Carolina, Sch Publ Hlth, Chapel Hill, NC 27599 USA
[3] US EPA, Human Studies Div, Natl Hlth & Environm Effects Lab, Off Res & Dev, Chapel Hill, NC 27599 USA
关键词
D O I
10.1088/1752-7155/2/2/026001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Environmental exposures, individual activities and disease states can perturb normal metabolic processes and be expressed as a change in the patterns of polar volatile organic compounds (PVOCs) present in biological fluids. We explore the measurement of volatile endogenous biomarkers to infer previous exposures to complex mixtures of environmental stressors. It is difficult to extract such compounds for ultra-trace level analysis due to their high solubility in water, especially when assaying complex liquid biological media such as exhaled breath condensate (EBC). Existing methods tend to be limited in sample volume processed and restricted in sample throughput. We have developed an alternative passive extraction method wherein a 2 ml sample is injected into a 75 ml glass bulb creating a small pool of liquid; a standard Tenax (R) sampling tube is inserted above the fluid and allowed to equilibrate with the headspace for similar to 24 h. The biomarker compounds are preferentially transferred by diffusion from the aqueous sample onto the Tenax (R) adsorbent; blanks and calibration samples are similarly processed. Numerous samples can be simultaneously prepared and stored awaiting routine analysis for a suite of alcohols and aldehydes using thermal desorption gas chromatography-mass spectrometry (GC-MS). We have optimized the procedures and estimated the sensitivity, precision and extraction efficiency resulting from the preparation and analytical procedures using synthetic samples. We subsequently demonstrated the method using anonymous biological specimens of EBC from healthy adults. The ultimate goal is to develop normal ranges and patterns for PVOCs to infer population-based environmental health states with simple spot measurements based on outlier determinations.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Detecting opioid metabolites in exhaled breath condensate (EBC)
    Borras, Eva
    Cheng, Andy
    Wun, Ted
    Reese, Kristen L.
    Frank, Matthias
    Schivo, Michael
    Davis, Cristina E.
    JOURNAL OF BREATH RESEARCH, 2019, 13 (04)
  • [2] Trace DNA in exhaled breath condensate (EBC)
    Spivack, Simon
    CANCER BIOMARKERS, 2008, 4 (03) : 160 - 161
  • [3] Asthma biomarkers in exhaled breath condensate (EBC)
    Limb, SL
    Hubbard, WC
    Wood, RA
    Adkinson, N
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2006, 117 (02) : S194 - S194
  • [4] Collection and analysis of exhaled breath condensate in humans
    Mutlu, GM
    Garey, KW
    Robbins, RA
    Danziger, LH
    Rubinstein, I
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (05) : 731 - 737
  • [5] cfDNA in exhaled breath condensate (EBC) and contamination by ambient air: toward volatile biopsies
    Koc, Altug
    Goksel, Tuncay
    Pelit, Levent
    Korba, Korcan
    Dizdas, Tugberk N.
    Baysal, Ertan
    Uzun, Umut C.
    Kaya, Ozge Ozer
    Ozyilmaz, Berk
    Kutbay, Yasar B.
    Ozdemir, Taha Resid
    Kirbiyik, Ozgur
    Erdogan, Kadri M.
    Guvenc, Merve Saka
    Kocal, Gizem Calibasi
    Basbinar, Yasemin
    JOURNAL OF BREATH RESEARCH, 2019, 13 (03)
  • [6] Repeatability of chloride levels in exhaled breath condensate (EBC)
    Zacharasiewicz, A
    Wilson, N
    Li, AM
    Lex, CH
    Hooper, J
    Bush, A
    THORAX, 2002, 57
  • [7] Exhaled breath condensate (EBC): An alternative or additional diagnostic?
    Becher, G
    Rothe, M
    Decker, M
    BREATH ANALYSIS: FOR CLINICAL DIAGNOSIS AND ATHERAPEUTIC MONITORING, 2005, : 421 - 427
  • [8] Exhaled breath condensate (EBC) pH in the evaluation of asthma
    Coop, C. A.
    Hagan, L. L.
    Dice, P.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 119 (01) : S88 - S88
  • [9] Exhaled Breath Condensate (EBC) Measurement and Lung Health
    Polatli, Mehmet
    TURKISH THORACIC JOURNAL, 2013, 14 : 32 - 36
  • [10] Exhaled breath condensate (EBC) biomarkers in pulmonary fibrosis
    Chow, Sharron
    Thomas, Paul S.
    Malouf, Monique
    Yates, Deborah H.
    JOURNAL OF BREATH RESEARCH, 2012, 6 (01)