Continuous Separation of White Blood Cells From Whole Blood Using Viscoelastic Effects

被引:22
|
作者
Tan, Justin K. S. [1 ]
Park, Sung-Yong [2 ]
Leo, Hwa Liang [1 ]
Kim, Sangho [1 ]
机构
[1] Natl Univ Singapore, Dept Biomed Engn, Singapore 117583, Singapore
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 117583, Singapore
基金
英国医学研究理事会;
关键词
Biomedical microelectromechanical systems; medical diagnosis; microfluidics; white blood cells; ALL-CAUSE MORTALITY; MAGNETOPHORETIC SEPARATION; MICROFLUIDIC DEVICE; FLOW FRACTIONATION; HEART-DISEASE; RISK-FACTORS; COUNT; CAPTURE; ACOUSTOPHORESIS; INSTABILITY;
D O I
10.1109/TBCAS.2017.2748232
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
White blood cells (WBCs) are the only cellular constituent containing genetic materials, and, hence, are candidate biomarkers for a host of diseases. However, conventional methods for WBC separation tend to have low sample purity and separation efficiency, whichwill have adverse implications on downstream polymerase chain reaction (PCR) analyses. In this study, we introduce a two-stage microfluidic device which harnesses the elastic property of a non-Newtonian fluid for size-based separation of WBCs from whole blood. The device displayed high resolution and efficiency in separating polystyrene particles and blood cells of different sizes up to a flow rate of 150 mu L/min in polyvinylpyrrolidone solutions. We performed a separate parametric study to evaluate the effects of the fluid elasticity and flow rate on the separation performance. The hematocrit of the blood sample was varied from 0.01% to 20% to investigate the effect of increased intercellular interactions on the separation efficiency. An optimized set of parameters was selected to demonstrate the applicability of the device to the separation ofWBCs fromdiluted whole blood, with excellent efficiency and purity (> 90%). This microfluidic device will be especially useful for blood fractionation applications requiring high sample purity and speedy processing. Additionally, the apparent flow-rate insensitivity of the separation allows for its potential use in point-of-care applications.
引用
收藏
页码:1431 / 1437
页数:7
相关论文
共 50 条
  • [1] Separation and Washing of Candida Cells from White Blood Cells Using Viscoelastic Microfluidics
    Lim, Hyunjung
    Kim, Jae Young
    Choo, Seunghee
    Lee, Changseok
    Han, Byoung Joe
    Lim, Chae Seung
    Nam, Jeonghun
    [J]. MICROMACHINES, 2023, 14 (04)
  • [2] A Microfluidic Device for Continuous White Blood Cell Separation and Lysis From Whole Blood
    Kim, Myounggon
    Jung, Seung Mo
    Lee, Kyeong-Hwan
    Kang, Yang Jun
    Yang, Sung
    [J]. ARTIFICIAL ORGANS, 2010, 34 (11) : 996 - 1002
  • [3] High-Throughput Separation of White Blood Cells From Whole Blood Using Inertial Microfluidics
    Zhang, Jun
    Yuan, Dan
    Sluyter, Ronald
    Yan, Sheng
    Zhao, Qianbin
    Xia, Huanming
    Tan, Say Hwa
    Nam-Trung Nguyen
    Li, Weihua
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (06) : 1422 - 1430
  • [4] Continuous magnetic separation of blood components from whole blood
    Takayasu, M
    Kelland, DR
    Minervini, JV
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 927 - 930
  • [5] Perfusion in microfluidic cross-flow: Separation of white blood cells from whole blood and exchange of medium in a continuous flow
    VanDelinder, Virginia
    Groisman, Alex
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (05) : 2023 - 2030
  • [6] CONTINUOUS SEPARATION OF WHITE BLOOD CELL FROM BLOOD IN A MICROFLUIDIC DEVICE
    Iliescu, Florina S.
    Sterian, Andreea P.
    Barbarini, Elena
    Avram, Marioara
    Iliescu, Ciprian
    [J]. UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2009, 71 (04): : 21 - 30
  • [7] APPLICATION OF CARRIER-FREE CONTINUOUS ELECTROPHORESIS FOR SEPARATION OF WHITE BLOOD CELLS FROM HUMAN BLOOD
    HANNIG, K
    KRUSMANN, WF
    [J]. HOPPE-SEYLERS ZEITSCHRIFT FUR PHYSIOLOGISCHE CHEMIE, 1968, 349 (02): : 161 - &
  • [8] Continuous Separation of Circulating Tumor Cells from Whole Blood Using a Slanted Weir Microfluidic Device
    Yoon, Yousang
    Lee, Jusin
    Ra, Moonsoo
    Gwon, Hyeokshin
    Lee, Seungwon
    Kim, Min Young
    Yoo, Ki-Chun
    Sul, Onejae
    Kim, Chul Geun
    Kim, Whoi-Yul
    Park, Jea-Gun
    Lee, Su-Jae
    Lee, Young Yiul
    Choi, Ho Soon
    Lee, Seung-Beck
    [J]. CANCERS, 2019, 11 (02):
  • [9] Microfluidic device for continuous magnetophoretic separation of white blood cells
    Iliescu, Ciprian
    Xu, Guolin
    Barbarini, Elena
    Avram, Marioara
    Avram, Andrei
    [J]. MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2009, 15 (08): : 1157 - 1162
  • [10] Microfluidic device for continuous magnetophoretic separation of white blood cells
    Ciprian Iliescu
    Guolin Xu
    Elena Barbarini
    Marioara Avram
    Andrei Avram
    [J]. Microsystem Technologies, 2009, 15 : 1157 - 1162