Wireless motion capture system using magnetically coupled LC resonant marker

被引:16
|
作者
Hashi, S
Tokunaga, Y
Yabukami, S
Kohno, T
Ozawa, T
Okazaki, Y
Ishiyama, K
Arai, KT
机构
[1] Gigu Univ, Dept Mat Sci & Technol, Gifu 5011193, Japan
[2] Tohoku Univ, Res Inst Elect Commun, Aoba Ku, Sendai, Miyagi 9808577, Japan
关键词
wireless sensing; motion capture; magnetically coupled LC resonant marker; electromagnetic induction;
D O I
10.1016/j.jmmm.2004.11.430
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel motion capture system using magnetically coupled LC resonant marker have been developed. This system composed from the LC marker, a driving coil and a pickup coil array. The marker consists only of an inductor and a capacitor without battery or electric wires, and driven wirelessly by the action of electromagnetic induction. The position accuracy was around 2 mm when the marker was located within the space of 50 mm apart from the pickup coil array. The system is applicable for highly accurate motion capturing without magnetic shielding because the system is free from the earth field. Additionally, it has a possibility of a multi-point motion capturing because the system allow markers to have an individual frequency band. © 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1330 / 1333
页数:4
相关论文
共 50 条
  • [1] Wireless magnetic motion capture system using multiple LC resonant magnetic markers with high accuracy
    Hashi, Shuichiro
    Toyoda, Masaharu
    Yabukami, Shin
    Ishiyama, Kazushi
    Okazaki, Yasuo
    Arai, Ken Ichi
    Kanetaka, Hiroyasu
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 142 (02) : 520 - 527
  • [2] Magnetic motion capture system using LC resonant magnetic marker composed of Ni-Zn ferrite core
    Hashi, S.
    Toyoda, M.
    Ohya, M.
    Okazaki, Y.
    Yabukami, S.
    Ishiyama, K.
    Arai, K. I.
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (08)
  • [3] Study on the LC marker composed of laminated amorphous ribbon core for a wireless magnetic motion capture system
    Hashi, S.
    Kamisaka, F.
    Yabukami, S.
    Kanetaka, H.
    Ishiyama, K.
    Arai, K. I.
    INTERNATIONAL CONFERENCE ON MAGNETISM (ICM 2009), 2010, 200
  • [4] A Misalignment Resilient System for Magnetically Coupled Resonant Wireless Power Transfer
    Liu, Zhu
    Chen, Zhizhang
    Peng, Cheng
    Liang, Jingcheng
    Xiao, Pei
    Bian, Lian
    Qiu, Yongfeng
    Li, Gaosheng
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2020, 68 (12) : 8260 - 8265
  • [5] Performance Analysis for the Magnetically Coupled Resonant Wireless Energy Transmission System
    Liu, Jinguo
    Zhang, Xuebin
    Yu, Jiahui
    Xu, Zhenyao
    Ju, Zhaojie
    COMPLEXITY, 2019, 2019
  • [6] A Planar Magnetically Coupled Resonant Wireless Power Transfer System Using Printed Spiral Coils
    Jolani, Farid
    Yu, Yiqiang
    Chen, Zhizhang
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2014, 13 : 1648 - 1651
  • [7] Coupler Loss Analysis of Magnetically Coupled Resonant Wireless Power Transfer System
    Li, Da
    Wu, XuSheng
    Gao, Wei
    Luo, Di
    Gao, Jianxin
    CES TRANSACTIONS ON ELECTRICAL MACHINES AND SYSTEMS, 2023, 7 (01) : 63 - 72
  • [8] Coupler Loss Analysis of Magnetically Coupled Resonant Wireless Power Transfer System
    Da Li
    XuSheng Wu
    Wei Gao
    Di Luo
    Jianxin Gao
    CESTransactionsonElectricalMachinesandSystems, 2023, 7 (01) : 63 - 72
  • [9] Study and Optimization of Transmission Characteristics of the Magnetically Coupled Resonant Wireless Transmission System
    Wen, Chunming
    Chen, Minbo
    Xu, Qing
    ELECTRONICS, 2022, 11 (13)
  • [10] Research and optimization of transmission characteristics of magnetically coupled resonant wireless transmission system
    Jiao Y.
    Li R.