Analysis of energy monitoring for a double-pulsed CO2 integrated path differential absorption lidar at 1.57 μm

被引:12
|
作者
Hu, Wenyi [1 ,2 ,3 ]
Liu, Jiqiao [1 ,2 ]
Zhu, Yadan [1 ,2 ,3 ]
Dong, Junfa [1 ,2 ,3 ]
Ma, Xiuhua [1 ,2 ]
Li, Shiguang [1 ,2 ]
Zhang, Junxuan [1 ,2 ]
Zhu, Xiaopeng [1 ,2 ]
Chen, Weibiao [1 ,2 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Key Lab Space Laser Commun & Detect Technol, Shanghai 201800, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Lab Space Laser Engn, Shanghai 201800, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
国家重点研发计划;
关键词
CARBON-DIOXIDE; SENSITIVITY; CALIBRATION; VALIDATION; SPECKLE; H2O; CH4;
D O I
10.1364/AO.58.000616
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For double-pulsed 1.57 mu m integrated path differential absorption lidar, the transmitted pulse energy measurement is an important factor that can influence the uncertainty of CO2 concentration measurement. An energy monitoring experiment was performed to determine how to improve the measurement precision of the transmitted pulse energy. Ground glass diffusers were used to reduce the speckle effect during energy monitoring. The roughness and rotational speed of the ground glass diffusers were considered and compared. The normalized energy ratios between on-line and off-line echo pulses and on-line and off-line energy monitoring pulses were analyzed, and the Allan deviation was used to evaluate the energy monitoring results. Averaging 148 shots, the standard deviation of the normalized energy ratio reached 0.0757%, whereas the correlation between the energy ratio of the on-line and off-line energy monitoring pulses and the energy ratio of the on-line and off-line echo pulses was higher than 90%. (C) 2019 Optical Society of America
引用
收藏
页码:616 / 625
页数:10
相关论文
共 50 条
  • [1] Airborne 2-micron double-pulsed integrated path differential absorption lidar for column CO2 measurement
    Singh, Upendra N.
    Yu, Jirong
    Petros, Mulugeta
    Refaat, Tamer F.
    Remus, Ruben G.
    Fay, James J.
    Reithmaier, Karl
    LIDAR TECHNOLOGIES, TECHNIQUES, AND MEASUREMENTS FOR ATMOSPHERIC REMOTE SENSING X, 2014, 9246
  • [2] Self-calibration and laser energy monitor validations for a double-pulsed 2-μm CO2 integrated path differential absorption lidar application
    Refaat, Tamer F.
    Singh, Upendra N.
    Petros, Mulugeta
    Remus, Ruben
    Yu, Jirong
    APPLIED OPTICS, 2015, 54 (24) : 7240 - 7251
  • [3] COLUMN CO2 MEASUREMENT FROM AN AIRBORNE SOLID-STATE DOUBLE-PULSED 2-MICRON INTEGRATED PATH DIFFERENTIAL ABSORPTION LIDAR
    Singh, U. N.
    Yu, J.
    Petros, M.
    Refaat, T. F.
    Remus, R.
    Fay, J.
    Reithmaier, K.
    INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [4] Analysis of Range Measurements From a Pulsed Airborne CO2 Integrated Path Differential Absorption Lidar
    Amediek, Axel
    Sun, Xiaoli
    Abshire, James B.
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (05): : 2498 - 2504
  • [5] Double-pulsed 2-μm lidar validation for atmospheric CO2 measurements
    Singh, Upendra N.
    Refaat, Tamer F.
    Yu, Jirong
    Petros, Mulugeta
    Remus, Ruben G.
    LIDAR TECHNOLOGIES, TECHNIQUES, AND MEASUREMENTS FOR ATMOSPHERIC REMOTE SENSING XI, 2015, 9645
  • [6] Diode-pumped double-pulsed Ho:Tm:LuLF laser at 2.05 μm for CO2 Differential Absorption Lidar (DIAL)
    Chen, SS
    Yu, JR
    Petros, M
    Bai, YX
    Trieu, BC
    Singh, UN
    Kavaya, MJ
    LASER RADAR TECHNIQUES FOR ATMOSPHERIC SENSING, 2004, 5575 : 44 - 49
  • [7] Development of a Pulsed 2-micron Integrated Path Differential Absorption Lidar for CO2 Measurement
    Singh, Upendra N.
    Yu, Jirong
    Petros, Mulugeta
    Refaat, Tamer F.
    Reithmaier, Karl
    LIDAR REMOTE SENSING FOR ENVIRONMENTAL MONITORING, 2013, 8872
  • [8] Wavelength-locking-free 1.57μm differential absorption lidar for CO2 sensing
    Liu, Hao
    Chen, Tao
    Shu, Rong
    Hong, Guanglie
    Zheng, Long
    Ge, Ye
    Hu, Yihua
    OPTICS EXPRESS, 2014, 22 (22): : 27675 - 27680
  • [9] Double-pulse 1.57 μm integrated path differential absorption lidar ground validation for atmospheric carbon dioxide measurement
    Du, Juan
    Zhu, Yadan
    Li, Shiguang
    Zhang, Junxuan
    Sun, Yanguang
    Zang, Huaguo
    Liu, Dan
    Ma, Xiuhua
    Bi, Decang
    Liu, Jiqiao
    Zhu, Xiaolei
    Chen, Weibiao
    APPLIED OPTICS, 2017, 56 (25) : 7053 - 7058
  • [10] 1.57 μm fiber source for atmospheric CO2 continuous-wave differential absorption lidar
    Yang, Xiong
    Lindberg, Robert
    Larsson, Jim
    Bood, Joakim
    Brydegaard, Mikkel
    Laurell, Fredrik
    OPTICS EXPRESS, 2019, 27 (07) : 10304 - 10310