Sensitivity of first-trimester ultrasound in the detection of congenital anomalies in twin pregnancies: population study and systematic review

被引:11
|
作者
D'Antonio, Francesco [1 ]
Familiari, Alessandra [1 ]
Thilaganathan, Basky [1 ]
Papageorghiou, Aris T. [1 ]
Manzoli, Lamberto [2 ,3 ]
Khalil, Asma [1 ]
Bhide, Amar [1 ]
机构
[1] St Georges Univ London, Div Dev Sci, Fetal Med Unit, London, England
[2] Univ G dAnnunzio, Dept Med & Aging Sci, Chieti, Italy
[3] CeSI Biotech, EMISAC, Chieti, Italy
关键词
Congenital anomalies; first trimester; multiple gestations; prenatal diagnosis; ultrasound; RUMP LENGTH DISCORDANCE; ABNORMALITIES; DIAGNOSIS; DEFECTS;
D O I
10.1111/aogs.13017
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Introduction. The first aim of this study was to ascertain the diagnostic performance of first-trimester ultrasound in detecting congenital anomalies in twins. The secondary aim was to explore the strength of association between different pregnancy characteristics and early detection of structural anomalies in a large unselected population of twin pregnancies. A systematic review of the published literature was also carried out. Material and methods. Retrospective analysis of prospectively collected data from consecutive twin pregnancies booked for antenatal care between 1996 and 2014. Predictive accuracy of those covariates independently associated with the occurrence of fetal anomalies was assessed with logistic regression analysis and receiver operating characteristics curves. Results. In all, 1064 twin pregnancies (820 dichorionic and 264 monochorionic) were included in the analysis. Forty-two pregnancies had one or more fetuses with structural abnormalities. Detection of structural abnormalities using ultrasound was possible in the first trimester in 27.3% (95% confidence interval 15.0-42.8) of twin pregnancies. Monochorionicity (odds ratio 2.3, 95% confidence interval 1.1-4.7) and discordance in crown-rump length and nuchal translucency were associated with an increased risk of fetal anomalies. However, their predictive accuracy was only moderate (areas under the curve 0.67, 95% confidence interval 0.6-0.8 and 0.68, 95% confidence interval 0.6-0.8, for crown-rump length and nuchal translucency discrepancy, respectively). Conclusions. First-trimester detection of structural abnormalities in twin pregnancies is possible in 27.3% (95% confidence interval 15.0-42.8) of cases. The likelihood for first-trimester detection of structural anomalies in twins was maximum for cranial vault, midline brain and abdominal wall defects. Monochorionicity and increasing discrepancy in crown-rump length and nuchal translucency were associated with fetal structural abnormalities, although their predictive performance was only moderately good.
引用
收藏
页码:1359 / 1367
页数:9
相关论文
共 50 条
  • [1] Evaluation of the role of first-trimester obstetric ultrasound in the detection of major anomalies: a systematic review
    Farraposo, Silvia
    Montenegro, Nuno
    Matias, Alexandra
    JOURNAL OF PERINATAL MEDICINE, 2014, 42 (02) : 141 - 149
  • [2] First-trimester ultrasound examination and the outcome of monochorionic twin pregnancies
    El Kateb, A.
    Nasr, B.
    Nassar, M.
    Bernard, J. P.
    Ville, Y.
    PRENATAL DIAGNOSIS, 2007, 27 (10) : 922 - 925
  • [3] First-trimester ultrasound detection of fetal heart anomalies: systematic review and meta-analysis
    Karim, J. N.
    Bradburn, E.
    Roberts, N.
    Papageorghiou, A. T.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2022, 59 (01) : 11 - 25
  • [4] Systematic review of first-trimester ultrasound screening for detection of fetal structural anomalies and factors that affect screening performance
    Karim, J. N.
    Roberts, N. W.
    Salomon, L. J.
    Papageorghiou, A. T.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 50 (04) : 429 - 441
  • [5] Systematic Review of First-Trimester Ultrasound Screening for Detection of Fetal Structural Anomalies and Factors That Affect Screening Performance
    Karim, J. N.
    Roberts, N. W.
    Salomon, L. J.
    Papageorghiou, A. T.
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2018, 73 (04) : 185 - 187
  • [6] Sensitivity and specificity of second trimester anatomy ultrasound in the detection of cardiac anomalies in fetal echocardiogram in twin pregnancies
    Lee, E.
    Ding, J.
    Kohari, K.
    Wong, J.
    Cross, S. N.
    Bahtiyar, M. O.
    Copel, J. A.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 252 - 252
  • [7] First-trimester screening for trisomies in pregnancies with vanishing twin
    Chaveeva, P.
    Wright, A.
    Syngelaki, A.
    Konstantinidou, L.
    Wright, D.
    Nicolaides, K. H.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2020, 55 (03) : 326 - 331
  • [8] FIRST-TRIMESTER PRENATAL-DIAGNOSIS IN TWIN PREGNANCIES
    CHRISTIAENS, GCML
    OOSTERWIJK, JC
    STIGTER, RH
    DEUTZTERLOUW, PP
    KNEPPERS, ALJ
    BAKKER, E
    PRENATAL DIAGNOSIS, 1994, 14 (01) : 51 - 55
  • [9] Does first-trimester ultrasound predict obstetrical outcomes in monochorionic diamniotic twin pregnancies?
    Allaf, M. Baraa
    Ravangard, Samadh
    Wax, Joseph
    Chavez, Martin R.
    Borgida, Adam
    Shamshirsaz, Amirhoushang A.
    Markenson, Glenn
    Vintzileos, Anthony
    Campbell, Winston
    Egan, James
    Figueroa, Reinaldo
    Cartia, Angelina
    Lee, Christopher
    Shamshirsaz, Alireza A.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (01) : S169 - S169
  • [10] A systematic review of the accuracy of first-trimester ultrasound examination for detecting major congenital heart disease
    Rasiah, S. V.
    Publicover, M.
    Ewer, A. K.
    Khan, K. S.
    Kilby, M. D.
    Zamora, J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (01) : 110 - 116