The Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor: multicentric evaluation of outcomes in adults and children

被引:6
|
作者
Franco-Vidal, Valerie [1 ]
Parietti-Winkler, Cecile [2 ]
Guevara, Nicolas [3 ]
Truy, Eric [4 ]
Loundon, Natalie [5 ]
Bailleux, Sonanda [6 ]
Ardoint, Marine [7 ]
Saai, Sonia [7 ]
Hoen, Michel [7 ]
Laplante-Levesque, Ariane [8 ,9 ]
Mosnier, Isabelle [10 ]
Bordure, Philippe [11 ]
Vincent, Christophe [12 ]
机构
[1] Bordeaux Univ Hosp, Ear Nose & Throat Dept, Bordeaux, France
[2] Cent Univ Hosp, Head & Neck Surg Dept, Nancy, France
[3] Univ Cote DAzur, Ctr Hosp Univ Nice, Inst Univ Face & Cou, Nice, France
[4] Lyon Univ Hosp, Otorhinolaryngol Phoniatry & Head & Neck Surg Dep, Lyon, France
[5] Necker Univ Hosp Sick Children, Ear Nose & Throat Dept, Paris, France
[6] Nice Lenval Univ Hosp, Ear Nose & Throat Dept, Nice, France
[7] Oticon Med, Clin Res, Vallauris, France
[8] Oticon Med, Clin Res, Kongebakken 9, DK-2765 Smorum, Denmark
[9] Linkoping Univ, Dept Behav Sci & Learning, Linkoping, Sweden
[10] Pitie Salpetriere Univ Hosp, Ear Nose & Throat Dept, Paris, France
[11] Nantes Univ Hosp, Ear Nose & Throat Dept, Nantes, France
[12] Lille Univ Hosp, Otol & Otoneurol Dept, Lille, France
关键词
Oticon Medical Neuro Zti and Neuro 2; cochlear implantation; sound processor; speech perception; CLINICAL-EVALUATION; SPEECH-PERCEPTION; PERFORMANCE; SYSTEM; NOISE; STIMULATION; COMPRESSION; STRATEGY;
D O I
10.1080/14992027.2019.1671616
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective: This study evaluated the outcomes of the Oticon Medical Neuro Zti cochlear implant and the Neuro 2 sound processor. Design: Neuro One users were upgraded to Neuro 2. Monosyllabic word identification was evaluated in adults with Neuro One after >= 5 months, with Neuro 2 at upgrade, and with Neuro 2 after 3 months. Self-reported listening ability, satisfaction, and usability were measured in adults and children. Study sample: Participants were 44 adults and 26 children. Results: Speech identification scores in quiet and noise were 58% and 45% with Neuro One and 67% and 55% with Neuro 2 after 3 months, respectively. Hearing impairment duration and number of active electrodes significantly predicted speech identification in noise with Neuro 2. Significantly higher questionnaire ratings were obtained for Neuro 2 than Neuro One regarding listening ability in complex listening situations, comfort and music, as well as nine aspects of satisfaction and usability. Conclusion: This study demonstrates the clinical superiority of the Neuro 2 sound processor over Neuro One in terms of speech identification in quiet and in noise and reported patient benefit and satisfaction. Given the study design, sources of improvement may include factors unrelated to the sound processor itself.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 4 条
  • [1] Evaluation of Noise-Canceling Strategies Used in the Oticon Medical Neuro Cochlear Implant Systems
    Celikgun, Bahtiyar
    Gurkan, Selhan
    B-ENT, 2024, 20 (01) : 13 - 18
  • [2] Adult Users of the Oticon Medical Neuro Cochlear Implant System Benefit from Beamforming in the High Frequencies
    Bastos Cordeiro, Bianca
    Banhara, Marcos Roberto
    Cardeal Mendes, Carlos Mauricio
    Danieli, Fabiana
    Laplante-Levesque, Ariane
    Karoui, Chadlia
    Hoen, Michel
    Ardoint, Marine
    Gauvrit, Fanny
    Demullier, Romane
    Vincent, Christophe
    AUDIOLOGY RESEARCH, 2021, 11 (02) : 179 - 191
  • [3] Clinical efficiency and safety of the oticon medical neuro cochlear implant system: a multicenter prospective longitudinal study
    Schramm, David
    Chen, Joseph
    Morris, David P.
    Shoman, Nael
    Philippon, Daniel
    Caye-Thomasen, Per
    Hoen, Michel
    Karoui, Chadlia
    Laplante-Levesque, Ariane
    Gnansia, Dan
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (09) : 959 - 967
  • [4] Sprachentwicklungstest für zweijährige Kinder (2;0–2;11 Jahre) – Auswertung multizentrischer Daten von Kindern mit Cochleaimplantat nach bilateraler VersorgungEine retrospektive LängsschnittuntersuchungSpeech development test for 2-year-olds (2;0–2;11 years)—evaluation of multicentric data of children after bilateral cochlear implant treatmentA retrospective longitudinal study
    Stefanie Kröger
    Antje Aschendorff
    Cynthia Glaubitz
    Kerstin Kreibohm-Strauß
    Dominique Kronesser
    Yvonne Seebens
    Barbara Streicher
    Fabian Overlach
    Stephanie Rother
    Rainer Beck
    HNO, 2025, 73 (5) : 311 - 320