Transient evoked otoacoustic emissions recorded using maximum length sequences from patients with sensorineural hearing loss

被引:4
|
作者
Hine, JE [1 ]
Thornton, ARD [1 ]
机构
[1] Royal S Hants Hosp, MRC, Inst Hearing Res, Southampton SO14 0YG, Hants, England
关键词
evoked otoacoustic emissions; maximum length sequences; hearing loss;
D O I
10.1016/j.heares.2004.11.019
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Much research has shown that transient evoked otoacoustic emissions (TEOAEs) can successfully separate normally hearing and hearing impaired populations. However, this finding comes from TEOAEs recorded using conventional averaging at low stimulation rates. Presenting clicks according to maximum length sequences (MLSs) enables TEOAEs to be recorded at very high stimulation rates. This study compares conventional and MLS TEOAEs in normally hearing and hearing impaired adults. Stimulus presentation rates of 40 clicks/s (conventional) and 5000 clicks/s (MLS) were used. The 'linear' TEOAEs (i.e., the directly recorded waveforms), the 'level nonlinear' (LNL) TEOAEs (i.e., those derived from two linear waveforms separated by a known difference in stimulus level) and the 'rate nonlinear' (RNL) TEOAEs (i.e., obtained by subtracting the emission recorded at 5000 clicks/s from that at 40 clicks/s at a fixed stimulus level) were examined to compare how they separated the normally hearing and hearing impaired subjects. When compared to the results for both conventional and MLS linear or LNL TEOAEs, the present study found that the RNL results best reflected the patients' hearing loss, although the conventional linear and LNL responses performed nearly as well. Only two impaired ears (2%), both with a best threshold of 30 dB HL at 1000 Hz, produced RNL responses with amplitude within the range produced by 95% of the normal group. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 133
页数:12
相关论文
共 50 条
  • [1] Volterra Slice otoacoustic emissions recorded using maximum length sequences from patients with sensorineural hearing loss
    de Boer, Jessica
    Thornton, A. Roger D.
    [J]. HEARING RESEARCH, 2006, 219 (1-2) : 121 - 136
  • [2] Transient evoked otoacoustic emissions recorded using maximum length sequences as a function of stimulus rate and level
    Hine, JE
    Thornton, ARD
    [J]. EAR AND HEARING, 1997, 18 (02): : 121 - 128
  • [3] Instrumentation for transient evoked otoacoustic emissions elicited by maximum length sequences
    Johannesen, PT
    Rasmussen, AN
    Osterhammel, PA
    [J]. SCANDINAVIAN AUDIOLOGY, 1998, 27 (01): : 37 - 42
  • [4] EVOKED OTOACOUSTIC EMISSIONS AND SENSORINEURAL HEARING-LOSS
    COLLET, L
    GARTNER, M
    MOULIN, A
    KAUFFMANN, I
    DISANT, F
    MORGON, A
    [J]. ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1989, 115 (09) : 1060 - 1062
  • [5] Effect of olivocochlear bundle section on evoked otoacoustic emissions recorded using maximum length sequences
    Hine, JE
    Thornton, ARD
    Brookes, GB
    [J]. HEARING RESEARCH, 1997, 108 (1-2) : 28 - 36
  • [6] Comparison of transient evoked otoacoustic emission thresholds recorded conventionally and using maximum length sequences
    Hine, JE
    Ho, CT
    Slaven, A
    Thornton, ARD
    [J]. HEARING RESEARCH, 2001, 156 (1-2) : 104 - 114
  • [7] Transient evoked otoacoustic emissions in patients with normal hearing and in patients with hearing loss
    Hussain, DM
    Gorga, MP
    Neely, ST
    Keefe, DH
    Peters, J
    [J]. EAR AND HEARING, 1998, 19 (06): : 434 - 449
  • [8] Maximum length sequences and Volterra series in the analysis of transient evoked otoacoustic emissions
    Thornton, ARD
    [J]. BRITISH JOURNAL OF AUDIOLOGY, 1997, 31 (06): : 493 - 498
  • [9] A STUDY ON NEONATAL HEARING LOSS USING TRANSIENT EVOKED OTOACOUSTIC EMISSIONS
    Sathyabhama, Jayaprabha
    Karat, Arathi
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (17): : 871 - 875
  • [10] STUDY OF HEARING LOSS IN INFANTS USING TRANSIENT EVOKED OTOACOUSTIC EMISSIONS
    Kulkarni, Shreeya
    Burse, Kiran S.
    Bharath, Manu
    Bharadwaj, Chaithanya
    Virendra, Manchanda Gunjan
    [J]. JOURNAL OF HEAD & NECK PHYSICIANS AND SURGEONS, 2014, 2 (01): : 105 - 120