Differential scanning calorimetry (DSC) and temperature-modulated DSC study of three mouthguard materials

被引:19
|
作者
Meng, Frank H.
Schricker, Scott R.
Brantley, William A.
Mendel, Deborah A.
Rashid, Robert G.
Fields, Henry W., Jr.
Vig, Katherine W. L.
Alapati, Satish B.
机构
[1] Ohio State Univ, Sect Restorat & Prosthet Dent, Columbus, OH 43218 USA
[2] Ohio State Univ, Coll Dent, Sect Orhodont, Columbus, OH 43218 USA
[3] Ohio State Univ, Coll Dent, Sect Primary Care, Columbus, OH 43218 USA
关键词
mouthguard materials; ethylene vinyl acetate; polymer structure; thermal analysis; differential scanning calorimetry; temperature-modulated differential; scanning calorimetry; Scanning electron microscopy;
D O I
10.1016/j.dental.2007.01.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Employ differential scanning calorimetry (DSC) and temperature-modulated DSC (TMDSC) to investigate thermal transformations in three mouthguard materials and provide insight into their previously investigated energy absorption. Methods. Samples (13-21mg) were obtained from (a) conventional ethylene vinyl acetate (EVA), (b) Pro-form (TM), another EVA polymer, and (c) PolyShok (TM) , an EVA polymer containing polyurethane. Conventional DSC (n=S) was first performed from -80 to 150 degrees C at a heating rate of 10C/min to determine the temperature range for structural transformations. Subsequently, TMDSC (n = 5) was performed from -20 to 150 degrees C at a heating rate of 1 degrees C/min. Onset and peak temperatures were compared using ANOVA and the Tukey-Kramer HSD test. Other samples were coated with a gold-palladium film and examined with an SEM. Results. DSC and TMDSC curves were similar for both conventional EVA and Pro-form (TM), showing two endothermic peaks suggestive of melting processes, with crystallization after the higher-temperature peak. Evidence for crystallization and the second endothermic peak were much less prominent for PolyShok (TM), which had no peaks associated with the polyurethane constituent. The onset of the lower-temperature endothermic transformation is near body temperature. No glass transitions were observed in the materials. SEM examination revealed different surface morphology and possible cushioning effect for PolyShok (TM), compared to Pro-form (TM) and EVA. Significance. The difference in thermal behavior for PolyShok (TM) is tentatively attributed to disruption of EVA crystal formation, which may contribute to its superior impact resistance. The lower-temperature endothermic peak suggests that impact testing of these materials should be performed at 37 degrees C. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1492 / 1499
页数:8
相关论文
共 50 条
  • [1] Application of the Advanced THermal Analysis System (ATHAS) to differential scanning calorimetry (DSC) and temperature-modulated DSC of polymers
    Wunderlich, B
    Pyda, M
    [J]. CONFERENCE PROCEEDINGS AT ANTEC '98: PLASTICS ON MY MIND, VOLS I-3: VOL I; PROCESSING, VOL II; SPECIAL AREAS, VOL III; MATERIALS, 1998, 44 : 2032 - 2036
  • [2] Application of the Advanced Thermal Analysis System (ATHAS) to differential scanning calorimetry (DSC) and temperature-modulated DSC of polymers
    Wunderlich, B
    Pyda, M
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1999, 18 (06) : 487 - 498
  • [3] Capability of conventional Differential Scanning Calorimetry (DSC), temperature modulated DSC (MDSC) and StepScan DSC for the glass transition phenomenon study
    Cernosek, Z.
    Holubova, J.
    Cernoskova, E.
    [J]. OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2007, 1 (06): : 277 - 280
  • [4] Study of crystallization kinetics by temperature-modulated DSC
    Chen, W
    Moon, IK
    Wunderlich, B
    [J]. POLYMER, 2000, 41 (11) : 4119 - 4125
  • [5] Differential scanning calorimetry and temperature-modulated differential scanning calorimetry:: an extension to lower temperatures
    Krüger, JK
    Manglkammer, W
    le Coutre, A
    Mesquida, P
    [J]. HIGH TEMPERATURES-HIGH PRESSURES, 2000, 32 (04) : 479 - 485
  • [6] Application of Differential Scanning Calorimetry (DSC) and Modulated Differential Scanning Calorimetry (MDSC) in Food and Drug Industries
    Leyva-Porras, Cesar
    Cruz-Alcantar, Pedro
    Espinosa-Solis, Vicente
    Martinez-Guerra, Eduardo
    Pinon-Balderrama, Claudia, I
    Compean Martinez, Isaac
    Saavedra-Leos, Maria Z.
    [J]. POLYMERS, 2020, 12 (01)
  • [7] Literature status on temperature-modulated differential scanning calorimetry
    Menczel, JD
    Judovits, L
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 1998, 54 (02): : 419 - 436
  • [8] Melting of indium by temperature-modulated differential scanning calorimetry
    Ishikiriyama, K
    Boller, A
    Wunderlich, B
    [J]. JOURNAL OF THERMAL ANALYSIS, 1997, 50 (04): : 547 - 558
  • [9] Temperature-modulated differential scanning calorimetry in a MEMS device
    Wang, Bin
    Lin, Qiao
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 180 : 60 - 65
  • [10] Literature Status on Temperature-Modulated Differential Scanning Calorimetry
    J. D. Menczel
    L. Judovits
    [J]. Journal of Thermal Analysis and Calorimetry, 1998, 54 : 419 - 436