Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers

被引:4
|
作者
Martin, M. J. [1 ]
Mantilla, J. M. [1 ]
del Campo, D. [1 ]
Hernanz, M. L. [2 ]
Pons, A. [2 ]
Campos, J. [2 ]
机构
[1] Ctr Espanol Metrol, Tres Cantos, Spain
[2] CSIC, Inst Opt, Madrid, Spain
关键词
Absolute radiometry; Radiance method; Radiometer; Standard radiation thermometer; Thermodynamic temperature; Uncertainty;
D O I
10.1007/s10765-017-2271-1
中图分类号
O414.1 [热力学];
学科分类号
摘要
The evolving mise en pratique for the definition of the kelvin (MeP-K) [1,2] will, in its forthcoming edition, encourage the realization and dissemination of the thermodynamic temperature either directly (primary thermometry) or indirectly (relative primary thermometry) via fixed points with assigned reference thermodynamic temperatures. In the last years, the Centro Espanol de Metrologia (CEM), in collaboration with the Instituto de Optica of Consejo Superior de Investigaciones Cientificas (IO-CSIC), has developed several setups for absolute calibration of standard radiation thermometers using the radiance method to allow CEM the direct dissemination of the thermodynamic temperature and the assignment of the thermodynamic temperatures to several fixed points. Different calibration facilities based on a monochromator and/or a laser and an integrating sphere have been developed to calibrate CEM's standard radiation thermometers (KE-LP2 and KE-LP4) and filter radiometer (FIRA2). This system is based on the one described in [3] placed in IO-CSIC. Different light sources have been tried and tested for measuring absolute spectral radiance responsivity: a Xe-Hg 500 W lamp, a supercontinuum laser NKT SuperK-EXR20 and a diode laser emitting at 6473 nm with a typical maximum power of 120 mW. Their advantages and disadvantages have been studied such as sensitivity to interferences generated by the laser inside the filter, flux stability generated by the radiant sources and so forth. This paper describes the setups used, the uncertainty budgets and the results obtained for the absolute temperatures of Cu, Co-C, Pt-C and Re-C fixed points, measured with the three thermometers with central wavelengths around 650 nm.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Performance of Different Light Sources for the Absolute Calibration of Radiation Thermometers
    M. J. Martín
    J. M. Mantilla
    D. del Campo
    M. L. Hernanz
    A. Pons
    J. Campos
    International Journal of Thermophysics, 2017, 38
  • [2] Monochromator-Based Absolute Calibration of Radiation Thermometers
    T. Keawprasert
    K. Anhalt
    D. R. Taubert
    J. Hartmann
    International Journal of Thermophysics, 2011, 32 : 1697 - 1706
  • [3] Monochromator-Based Absolute Calibration of Radiation Thermometers
    Keawprasert, T.
    Anhalt, K.
    Taubert, D. R.
    Hartmann, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (7-8) : 1697 - 1706
  • [4] Supercontinuum-Source-Based Facility for Absolute Calibration of Radiation Thermometers
    Y. Yamaguchi
    Y. Yamada
    J. Ishii
    International Journal of Thermophysics, 2015, 36 : 1825 - 1833
  • [5] New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers
    K. Anhalt
    A. Zelenjuk
    D. R. Taubert
    T. Keawprasert
    J. Hartmann
    International Journal of Thermophysics, 2009, 30 : 192 - 202
  • [6] Supercontinuum-Source-Based Facility for Absolute Calibration of Radiation Thermometers
    Yamaguchi, Y.
    Yamada, Y.
    Ishii, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2015, 36 (08) : 1825 - 1833
  • [7] ABSOLUTE CALIBRATION OF LIGHT SOURCES IN VACUUM ULTRAVIOLET BY MEANS OF SYNCHROTRON RADIATION OF DESY
    PITZ, E
    APPLIED OPTICS, 1969, 8 (02): : 255 - &
  • [8] New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers
    Anhalt, K.
    Zelenjuk, A.
    Taubert, D. R.
    Keawprasert, T.
    Hartmann, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2009, 30 (01) : 192 - 202
  • [9] CALIBRATION OF RADIATION THERMOMETERS
    PEACOCK, GR
    1988 WORKSHOP AND SYMPOSIUM, TECHNICAL PRESENTATIONS : COMPETITIVENESS IN A WORLD MARKET, 1988, : 533 - 545