Determination of triamcinolone in human plasma by a sensitive HPLC-ESI-MS/MS method: application for a pharmacokinetic study using nasal spray formulation

被引:10
|
作者
Cesar, Isabela Costa [1 ,2 ]
Duarte Byrro, Ricardo Martins [1 ,2 ]
de Santana e Silva Cardoso, Fabiana Fernandes [2 ]
Mundim, Iram Moreira [2 ]
Teixeira, Leonardo de Souza [2 ]
de Sousa, Weidson Carlo [2 ]
Gomes, Sandro Antonio [2 ]
Bellorio, Karini Bruno [2 ]
Bretas, Juliana Machado [1 ]
Pianetti, Gerson Antonio [1 ]
机构
[1] Univ Fed Minas Gerais, Fac Farm, Dept Prod Farmaceut, BR-31270901 Belo Horizonte, MG, Brazil
[2] Inst Ciencias Farmaceut, BR-74175100 Goiania, Go, Brazil
来源
JOURNAL OF MASS SPECTROMETRY | 2011年 / 46卷 / 03期
关键词
triamcinolone; nasal spray; HPLC-ESI-MS/MS; plasma; pharmacokinetics; MASS-SPECTROMETRY METHOD; ALLERGIC RHINITIS; INTRANASAL; BIOEQUIVALENCE; CORTICOSTEROIDS; ACETONIDE; EFFICACY;
D O I
10.1002/jms.1896
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for the quantitation of triamcinolone in human plasma after nasal spray application was developed and validated. Betamethasone was used as internal standard (IS). The analytes were extracted by a liquid-liquid procedure and separated on a Zorbax Eclipse XDB C-18 column with a mobile phase composed of 2 mM aqueous ammonium acetate pH 3.2 and acetonitrile (55 : 45). Selected reaction monitoring was performed using the transitions m/z 435 -> 415 and m/z 393 -> 373 to quantify triamcinolone acetonide and betamethasone, respectively. Calibration curve was constructed over the range of 20-2000 pg/ml for triamcinolone acetonide. The lower limit of quantitation was 20 pg/ml. The mean RSD values were 4.6% and 5.7% for the intra-run and inter-run precision, respectively. The mean accuracy value was 98.5% and a recovery rate corresponding to 97.5% was achieved. No matrix effect was detected in the samples. The validated method was successfully applied to determine the plasma concentrations of triamcinolone acetonide in healthy volunteers, in a pharmacokinetic study with nasal spray formulation. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:320 / 326
页数:7
相关论文
共 50 条
  • [1] Determination of Voriconazole in Human Plasma by HPLC-ESI-MS and Application to Pharmacokinetic Study
    Lin, Dai
    Li, Guoliang
    Chen, Lingyun
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2013, 51 (06) : 485 - 489
  • [2] A simple and sensitive HPLC-ESI-MS/MS method for the determination of andrographolide in human plasma
    Xu, Li
    Xiao, Da-wei
    Lou, Sheng
    Zou, Jian-jun
    Zhu, Yu-bing
    Fan, Hong-wei
    Wang, Guang-ji
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 502 - 506
  • [3] Sensitive HPLC-ESI-MS method for the determination of tiotropium in human plasma
    Ding, Li
    Tan, Wenming
    Zhang, Yindi
    Shen, Jianping
    Zhang, Zhengxing
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2008, 46 (05) : 445 - 449
  • [4] Determination of Irsogladine Using HPLC-ESI-MS/MS in Human Plasma: Application to Bioequivalence Study
    Nguyen Huu Hoang
    Nguyen Lan Huong
    Hong, Sung-Yong
    Park, Je Won
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (08): : 1894 - 1898
  • [5] A validated HPLC-ESI-MS method for the determination of loratadine in human plasma and its application to pharmacokinetic studies
    Chen, J
    Zha, Y
    Gao, KP
    Shi, ZQ
    Jiang, XG
    Jiang, WM
    Gao, XL
    PHARMAZIE, 2004, 59 (08): : 600 - 603
  • [6] Fast and Sensitive HPLC-ESI-MS/MS Method for Etoricoxib Quantification in Human Plasma and Application to Bioequivalence Study
    Loh, Gabriel Onn Kit
    Wong, Emily Yii Ling
    Tan, Yvonne Tze Fung
    Heng, Siew Chyee
    Saaid, Mardiana
    Cheah, Kit Yee
    Sali, Nurul Diyana Mohd
    Damenthi, Nair
    Ng, Sharon Shi Min
    Ming, Long Chiau
    Peh, Kok Khiang
    MOLECULES, 2022, 27 (17):
  • [7] Determination of Puquitinib in Human Plasma by HPLC–ESI MS/MS: Application to Pharmacokinetic Study
    Jing Zhan
    Ya Ding
    Benyan Zou
    Hai Liao
    Wenqi Jiang
    Su Li
    European Journal of Drug Metabolism and Pharmacokinetics, 2018, 43 : 555 - 564
  • [8] Development and validation of a sensitive HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma
    Roda, Aldo
    Sabatini, Laura
    Barbieri, Anna
    Guardigli, Massimo
    Locatelli, Marcello
    Saverio Violante, Francesco
    Rovati, Lucio C.
    Persiani, Stefano
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 119 - 126
  • [9] Simultaneous Determination and Pharmacokinetic Study of Metformin and Rosiglitazone in Human Plasma by HPLC-ESI-MS
    Chen, Lingyun
    Zhou, Zhifeng
    Shen, Mei
    Ma, Ande
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2011, 49 (02) : 94 - 100
  • [10] A new quantitation method of protodioscin by HPLC-ESI-MS/MS in rat plasma and its application to the pharmacokinetic study
    Zhang, Xinxin
    Guo, Zengjun
    Li, Jing
    Ito, Yoichiro
    Sun, Wenji
    STEROIDS, 2016, 106 : 62 - 69