Secure Remote Backup Protection of Transmission Lines Using Synchrophasors

被引:62
|
作者
Navalkar, Prashant V. [1 ]
Soman, Shreevardhan A. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Bombay 400076, Maharashtra, India
关键词
Adaptive relaying; distance protection; phasor measurement unit (PMU); state estimation (SE);
D O I
10.1109/TPWRD.2010.2076350
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We consider the problem of detecting a fault on a transmission line from the residual vector of a synchrophasor state estimator (SynSE). For a transmission line under fault, we identify six operating modes depending upon location of the phasor measurement units (PMUs). We show that in five operating modes, the fault is seen in the residual vector while in one mode, the fault will not reflect in the residual vector. The analysis leads us to propose a remote backup protection scheme for supervised zone-3 operation of distance relays. In case of inadequate PMU penetration in the system, the implementation of SynSE can even be restricted to a small subsystem of critical lines.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 50 条
  • [1] Secure Backup Protection of Transmission Line using WAMS
    Hinge, Trupti
    Dambhare, S. S.
    2014 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2014,
  • [2] Secure Phase Comparison Schemes for Transmission-Line Protection Using Synchrophasors
    Hinge, Trupti P.
    Dambhare, Sanjay S.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (04) : 2045 - 2054
  • [3] A Backup Protection Approach for Multisection Compound Transmission Lines
    Abdel-bary, A. S.
    Emam, A. M.
    Elghazaly, H. A.
    PROCEEDINGS OF 2016 EIGHTEENTH INTERNATIONAL MIDDLE EAST POWER SYSTEMS CONFERENCE (MEPCON), 2016, : 129 - 137
  • [4] System Integrity Protection Scheme for Enhancing Backup Protection of Transmission Lines
    Sahoo, Biswajit
    Samantaray, Subhransu Ranjan
    IEEE SYSTEMS JOURNAL, 2021, 15 (03): : 4578 - 4588
  • [5] Instantaneous protection scheme for backup protection of high-voltage transmission lines
    Syed Nasir, Syed Norazizul
    Mohd Zin, Abdullah Asuhaimi
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2017, 25 (04) : 3261 - 3272
  • [6] An Adaptive Secure-Dependable Wide-Area Backup Protection Scheme for Transmission Lines Using Multi-Phasor Measurement Units
    Mallikarjuna, B.
    Meyur, Rounak
    Pal, Diptak
    Reddy, M. Jaya Bharata
    Mohanta, D. K.
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [7] Remote backup protection for substation
    Sui, Fenghai
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 1999, 23 (20):
  • [8] An adaptive supervised wide-area backup protection scheme for transmission lines protection
    B. Mallikarjuna
    P. V. Vardhan Varma
    S. D. Samir
    M. Jaya Bharata Reddy
    D. K. Mohanta
    Protection and Control of Modern Power Systems, 2017, 2 (1)
  • [9] Remote backup protection for substation
    Sui, Fenghai
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 1999, 23 (20): : 27 - 28
  • [10] Automated Failure Diagnosis in Transmission Network Protection System Using Synchrophasors
    Cui, B.
    Srivastava, A. K.
    Banerjee, P.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (05) : 2207 - 2216