Live-Load Performance Evaluation of Historic Covered Timber Bridges in the United States

被引:10
|
作者
Seo, Junwon [1 ]
Hosteng, Travis K. [2 ]
Phares, Brent M. [3 ]
Wacker, James P. [4 ]
机构
[1] South Dakota State Univ, Dept Civil & Environm Engn, Brookings, SD 57007 USA
[2] Natl Ctr Wood Transportat Struct, 2711 S Loop Dr,Suite 4700, Ames, IA 50010 USA
[3] Iowa State Univ, Bridge Engn Ctr, 2711 S Loop Dr,Suite 4700, Ames, IA 50010 USA
[4] US Forest Serv, USDA, Forest Prod Lab, 1 Gifford Pinchot Dr, Madison, WI 53726 USA
关键词
Field testing; Live-load performance; Timber; Covered bridges; Burr arch truss; Howe truss; Queen post truss; HEALTH MONITORING-SYSTEM; FATIGUE; MODELS;
D O I
10.1061/(ASCE)CF.1943-5509.0000852
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The National Historic Covered Bridge Preservation Program (NHCBP), sponsored by the Federal Highway Administration (FHWA), was established to preserve the covered timber bridge structures that were constructed in the early 1800s. Today, many of the approximately 880 covered timber bridges still in existence in the United States are closed to vehicular traffic; furthermore, a large percentage of the remaining bridges open to traffic are restricted by load postings. Unfortunately, there are no current load-rating standards for covered timber bridges, so engineers do not have many resources at their disposal to reliably understand the behavior of these complex structures. As a result, the estimated load postings and/or ratings are often too conservative. To better understand the live-load performance of covered timber bridges and to develop improved criteria for their load ratings, a series of live-load tests were performed on 11 single-span, historic covered timber bridges. This paper explains the field testing conducted on all of the bridges, and makes recommendations for the conduct of other similar tests. The tests consisted of installing a network of multiple displacement and strain sensors on the structures, and monitoring global displacements and member strains at various cross sections during passage of a known test. The vehicle used in the testing met the load restrictions in place at the time of testing. The results of this work serve as a basis for instrumentation and field testing, to investigate the live-load performance on such bridges. This paper outlines the field-testing methods and summarizes the results from the testing of all 11 bridges. Based on the field-testing methods, a field-testing protocol is recommended for the live-load testing of historic covered timber bridges. Feasibility of the recommended protocol is also evaluated using a finite-element model analysis for a selected bridge among the tested bridges. (C) 2015 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Development of Live-Load Distribution Factors for Glued-Laminated Timber Girder Bridges
    Fanous, Fouad
    May, Jeremy
    Wipf, Terry
    JOURNAL OF BRIDGE ENGINEERING, 2011, 16 (02) : 179 - 187
  • [2] Live-load moments for continuous skew bridges
    Khaleel, Mohammad A.
    Itani, Rafik Y.
    Journal of structural engineering New York, N.Y., 1990, 116 (09): : 2361 - 2373
  • [3] Evaluation of live-load distribution factors for high-performance prestressed concrete girder bridges
    Dwairi, Hazim
    Al-Hattamleh, Omar
    Al-Qablan, Husam
    BRIDGE STRUCTURES, 2019, 15 (1-2) : 15 - 26
  • [4] LIVE-LOAD MOMENTS FOR CONTINUOUS SKEW BRIDGES
    KHALEEL, MA
    ITANI, RY
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (09): : 2361 - 2373
  • [5] LIVE-LOAD MOMENTS FOR CONTINUOUS SKEW BRIDGES - DISCUSSION
    BAKHT, B
    JAEGER, LG
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (03): : 870 - 871
  • [6] LIVE-LOAD MOMENTS FOR CONTINUOUS SKEW BRIDGES - CLOSURE
    KHALEEL, MA
    ITANI, RY
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (03): : 871 - 872
  • [7] Rehabilitation of two historic timber covered bridges in Massachusetts
    Lee, S. D. Daniel
    Brenner, Brian
    HISTORIC BRIDGES: EVALUATION, PRESERVATION, AND MANAGEMENT, 2008, : 243 - 259
  • [8] Design Live-Load Factor Calibration for Michigan Highway Bridges
    Eamon, Christopher D.
    Kamjoo, Valid
    Shinki, Kazuhiko
    JOURNAL OF BRIDGE ENGINEERING, 2016, 21 (06)
  • [9] Live-Load Analysis of Posttensioned Box-Girder Bridges
    Hodson, Dereck J.
    Barr, Paul J.
    Halling, Marvin W.
    JOURNAL OF BRIDGE ENGINEERING, 2012, 17 (04) : 644 - 651
  • [10] Live-load distribution factors in prestressed concrete girder bridges
    Barr, P.J.
    Eberhard, M.O.
    Stanton, J.F.