Sensitive voltammetric determination of baicalein at DNA Langmuir-Blodgett film modified glassy carbon electrode

被引:24
|
作者
Wang, Fei [1 ,2 ]
Zhao, Fangyuan [1 ]
Zhang, Yanzheng [1 ]
Yang, Huige [1 ]
Ye, Baoxian [1 ]
机构
[1] Zhengzhou Univ, Dept Chem, Zhengzhou 450052, Peoples R China
[2] Henan Inst Engn, Dept Mat & Chem Engn, Zhengzhou 450007, Peoples R China
基金
中国国家自然科学基金;
关键词
Baicalein; Square wave voltammetry; Langmuir-Blodgett film; DNA; CANCER CELL-LINES; SCUTELLARIAE-RADIX; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL DETECTION; WOGONIN; ACID; ANTIOXIDANT; FLAVONOIDS; BIOSENSOR; BEHAVIOR;
D O I
10.1016/j.talanta.2010.12.036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes to modify a double stranded DNA-octadecylamine (ODA) Langmuir-Blodgett film on a glassy carbon electrode (GCE) surface to develop a voltammetric sensor for the detection of trace amounts of baicalein. The electrode was characterized by atomic force microscopy (AFM) and cyclic voltammetry (CV). Electrochemical behaviour of baicalein at the modified electrode had been investigated in pH 2.87 Britton-Robinson buffer solutions by CV and square wave voltammetry (SWV). Compared with bare GCE, the electrode presented an electrocatalytic redox for baicalein. Under the optimum conditions, the modified electrode showed a linear voltammetric response for the baicalein within a concentration range of 1.0 x 10(-8)-2.0 x 10(-6) mol L-1, and a value of 6.0 x 10(-9) mol L-1 was calculated for the detection limit. And the modified electrode exhibited an excellent immunity from epinephrine, dopamine, glucose and ascorbic acid interference. The method was also applied successfully to detect baicalein in the medicinal tablets and spiked human blood serum samples with satisfactory results. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [1] Voltammetric response of a glassy carbon electrode modified by a Langmuir-Blodgett film of a thiomacrocyclic compound
    Guaus, E.
    Errachid, A.
    Torrent-Burgues, J.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 614 (1-2) : 73 - 82
  • [2] DNA Langmuir-Blodgett modified glassy carbon electrode as voltammetric sensor for determinate of methotrexate
    Wang, Fei
    Wu, Yanju
    Liu, Jinxia
    Ye, Baoxian
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (05) : 1408 - 1413
  • [3] Polyaniline Langmuir-Blodgett film modified glassy carbon electrode as a voltammetric sensor for determination of Ag+ ions
    Liu, Qiongyan
    Wang, Fei
    Qiao, Yonghui
    Zhang, Shusheng
    Ye, Baoxian
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (05) : 1795 - 1800
  • [4] A Glassy Carbon Electrode Modified with Langmuir - Blodgett Film Composed of DNA and Polyaniline for the Sensitive Determination of Salbutamol
    Zou, Lina
    Li, Yinfeng
    Cao, Shaokui
    Ye, Baoxian
    [J]. ELECTROANALYSIS, 2014, 26 (05) : 1051 - 1058
  • [5] Simultaneous voltammetric determination of dopamine and uric acid based on Langmuir-Blodgett film of calixarene modified glassy carbon electrode
    Wang, Fei
    Chi, Chang Long
    Yu, Bo
    Ye, Baoxian
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1586 - 1593
  • [6] Langmuir-Blodgett film of p-tert-butylthiacalix[4]arene modified glassy carbon electrode as voltammetric sensor for the determination of Hg(II)
    Wang, Fei
    Wei, Xiaohan
    Wang, Chenbin
    Zhang, Shusheng
    Ye, Baoxian
    [J]. TALANTA, 2010, 80 (03) : 1198 - 1204
  • [7] Langmuir-Blodgett film of p-tert-butylthiacalix[4]arene modified glassy carbon electrode as voltammetric sensor for the determination of Ag+
    Wang, Fei
    Liu, Qiongyan
    Wu, Yanju
    Ye, Baoxian
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 630 (1-2) : 49 - 54
  • [8] Gold nanoparticles/polyaniline Langmuir-Blodgett Film modified glassy carbon electrode as voltammetric sensor for detection of epinephrine and uric acid
    Zou, Lina
    Li, Yinfeng
    Cao, Shaokui
    Ye, Baoxian
    [J]. TALANTA, 2013, 117 : 333 - 337
  • [9] Glassy Carbon Electrode Modified with a Langmuir-Blodgett Film of a Thiomacrocyclic Ionophore for Cu(II) Recognition
    Guaus, E.
    Torrent-Burgues, J.
    Zine, N.
    Errachid, A.
    [J]. SENSOR LETTERS, 2009, 7 (05) : 1006 - 1011
  • [10] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    [J]. ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144