Color stability of fully- and pre-crystalized chair-side CAD-CAM lithium disilicate restorations after required and additional sintering processes

被引:9
|
作者
Jurado, Carlos Alberto [1 ]
El-Gendy, Tamer [2 ]
Hyer, Jared [2 ]
Tsujimoto, Akimasa [3 ]
机构
[1] Texas Tech Univ Hlth Sci Ctr El Paso, Woody L Hunt Sch Dent Med, El Paso, TX USA
[2] AT Still Univ Arizona, Sch Dent & Oral Hlth, 5855 East Still Circle, Mesa, AZ 85206 USA
[3] Univ Iowa, Coll Dent, Dept Operat Dent, Iowa City, IA 52242 USA
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2022年 / 14卷 / 01期
关键词
Prosthodontics; Ceramics; Crowns; Dentistry; Esthetics; CROWNS; VENEERS; CAD/CAM; SHADE;
D O I
10.4047/jap.2022.14.1.56
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. The aim of this study was to investigate shade changes in fully-and pre-crystalized CAD-CAM lithium disilicate crowns after the required and addition -al firing processes. MATERIALS AND METHODS. One hundred and five crowns of shade A1 with high translucency were milled out of CAD-CAM lithium disilicate blocks and categorized as follows (n = 15): (1) restorations fabricated from Strau-mann n!ce with no additional sintering process; (2) restorations fabricated from Straumann n!ce with one additional sintering process; (3) restorations fabricated from Straumann n!ce with two additional sintering processes; (4) restorations fab-ricated from Amber Mill with one sintering process; (5) restorations fabricated from Amber Mill with two sintering processes; (6) restorations fabricated from IPS e.max CAD with one sintering process; (7) restorations fabricated from IPS e.max CAD with two sintering processes. All restorations were evaluated with a color imaging spectrophotometer. RESULTS. All restorations presented some color alteration from the original shade both after a single and after two firing processes. CONCLU-SION. The required and additional sintering processes for restorations fabricated with chairside CAD-CAM lithium disilicate blocks cause an alteration of the original shade selected. Shade A1 high translucency restorations tend to change to a more yellowish B1 shade after a sintering process. [J Adv Prosthodont 2022;14:56-62]
引用
收藏
页码:56 / 62
页数:7
相关论文
共 2 条
  • [1] Fracture load of chairside CAD-CAM veneers fabricated with pre-and fully crystalized lithium disilicate ceramics
    Jurado, Carlos A.
    Yeh, Jacquelyn S.
    Vidal, Cristina M. P.
    Cho, Seok-Hwan
    Abuhammoud, Salahaldeen
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [2] Reliability of Chair-side Monolithic CAD-CAM Generated Lithium Disilicate Single Crowns with Knife-Edge Finish Line: Up to 5-Year Retrospective Analysis of Clinical Performance
    Scutella, Fabio
    Weinstein, Tommaso
    Redaelli, Sara
    Cerutti, Antonio
    Testori, Tiziano
    Ozcan, Mutlu
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (02): : 94 - 97