A randomized prospective comparison of self-expandable plastic stents and partially covered self-expandable metal stents in the palliation of malignant esophageal dysphagia

被引:144
|
作者
Conio, Massimo
Repici, Alessandro
Battaglia, Giorgio
De Pretis, Giovanni
Ghezzo, Luigi
Bittinger, Max
Messmann, Helmut
Demarquay, Jean-Francois
Blanchi, Sabrina
Togni, Michele
Conigliaro, Rita
Filiberti, Rosangela
机构
[1] Sanremo Hosp, Dept Gastroenterol, San Remo, Italy
[2] Ist Clin Humanitas, Dept Digest Endoscopy, Rozzano, Italy
[3] Univ Padua, Dept Med & Surg Sci, Padua, Italy
[4] Santa Chiara Hosp, Dept Gastroenterol, Trento, Italy
[5] S Croce & Carle Hosp, Dept Gastroenterol, Cuneo, Italy
[6] Zentral Klinikum Augsburg, Dept Internal Med 3, Augsburg, Germany
[7] Univ Hosp, Dept Gastroenterol, Nice, France
[8] Arcispedale S Maria Nuova, Dept Digest Endoscopy, Reggio Emilia, Italy
[9] Natl Inst Canc Res, Dept Epidemiol & Biostat, Genoa, Italy
来源
AMERICAN JOURNAL OF GASTROENTEROLOGY | 2007年 / 102卷 / 12期
关键词
D O I
10.1111/j.1572-0241.2007.01565.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVES: Self-expanding metal stents (SEMS) provide effective palliation in patients with malignant dysphagia, although severe complications and mortality may result. We performed a prospective controlled trial to compare a new self-expanding polyester mesh stent (Polyflex) with SEMS (Ultraflex). METHODS: One hundred one patients with unresectable esophageal carcinoma were randomized to placement of a Polyflex (N = 47) or a partially covered Ultraflex (N = 54) stent. Patients with esophagogastric junction (EGJ) malignancy were excluded. RESULTS: Placement was successful in 46 (98%) patients with the Polyflex and 54 (100%) patients with the Ultraflex stent. In one patient, the Polyflex stent could not be placed. After 1 wk, dysphagia was improved by at least 1 grade in 100% of the Polyflex group and in 94% of the Ultraflex group. Major complications were observed in 48% of the Polyflex group and 33% of the Ultraflex group. Intraprocedural perforation occurred in 1 Polyflex and 1 Ultraflex patient. Two Polyflex patients had postprocedural hemorrhage. Twenty (44%) patients with a Polyflex stent and 18 (33%) with an Ultraflex stent had recurrent dysphagia because of tumor overgrowth, stent migration, hyperplastic granulomatous reaction, or food bolus impaction. Multivariate analysis showed a significantly higher complication rate with Polyflex than with Ultraflex stents (odds ratio 2.3, 95% CI 1.2-4.4). However, median survival was 134 days with Polyflex and 122 days with Ultraflex stents (P = NS). CONCLUSIONS: No difference was seen in palliation of dysphagia between the two stents. Significantly more complications, especially late stent migration, were observed in the Polyflex group.
引用
收藏
页码:2667 / 2677
页数:11
相关论文
共 50 条
  • [1] SELF-EXPANDABLE METAL STENTS IN PALLIATION OF MALIGNANT ESOPHAGEAL OBSTRUCTION
    Hameed, Khalid
    Khan, Hashmatullah
    Din, Rahman Ud
    Khan, Jandil
    Rehman, Adnan Ur
    Rashid, Murad
    [J]. GOMAL JOURNAL OF MEDICAL SCIENCES, 2010, 8 (01): : 39 - 43
  • [2] Self-expandable metal stents for malignant dysphagia
    Lam, YH
    Chan, A
    Lau, J
    Lee, D
    Ng, E
    Wong, S
    Chung, S
    [J]. AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1999, 65 (09): : 668 - 671
  • [3] Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks
    Petra GA van Boeckel
    Kulwinder S Dua
    Bas LAM Weusten
    Ruben JH Schmits
    Naveen Surapaneni
    Robin Timmer
    Frank P Vleggaar
    Peter D Siersema
    [J]. BMC Gastroenterology, 12
  • [4] Fully covered self-expandable metal stents (SEMS), partially covered SEMS and self-expandable plastic stents for the treatment of benign esophageal ruptures and anastomotic leaks
    van Boeckel, Petra G. A.
    Dua, Kulwinder S.
    Weusten, Bas L. A. M.
    Schmits, Ruben J. H.
    Surapaneni, Naveen
    Timmer, Robin
    Vleggaar, Frank P.
    Siersema, Peter D.
    [J]. BMC GASTROENTEROLOGY, 2012, 12
  • [5] The use of small-caliber, covered, self-expandable metal stents for palliation of severe malignant dysphagia
    Kucera, S.
    Harris, C. L.
    Vignesh, S.
    Klapman, J.
    Barthel, J. S.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (04)
  • [6] A randomized trial comparing uncovered and partially covered self-expandable metal stents in the palliation of distal malignant biliary obstruction
    Telford, Jennifer J.
    Carr-Locke, David L.
    Baron, Todd H.
    Poneros, John M.
    Bounds, Brenna C.
    Kelsey, Peter B.
    Schapiro, Robert H.
    Huang, Christopher S.
    Lichtenstein, David R.
    Jacobson, Brian C.
    Saltzman, John R.
    Thompson, Christopher C.
    Forcione, David G.
    Gostout, Christopher J.
    Brugge, William R.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2010, 72 (05) : 907 - 914
  • [7] Self-expandable metal stents
    Dumonceau, JM
    Devière, J
    [J]. BEST PRACTICE & RESEARCH CLINICAL GASTROENTEROLOGY, 1999, 13 (01) : 109 - 130
  • [8] Palliative treatment of malignant esophageal stenosis: Plastic or self-expandable metal stents?
    Delis, VC
    Balatsos, VE
    Vamvakousis, VC
    Kassapidis, PP
    Konstantinidis, AC
    Hatzinicolaou, AS
    Giannakopoulos, AV
    Skandalis, NP
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : AB253 - AB253
  • [9] Self Expandable Metal Stents for Palliation of Neoplastic Esophageal Stricture: A Comparison of Covered and Partially Covered Stents
    Pearce, Steven
    Osowo, Ayodele
    Dekovich, Alexander
    Jeevanantham, Vinodh
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 : S20 - S20
  • [10] Development of self-expandable covered stents
    Sato, Sachiko
    Nakayama, Yasuhide
    Miura, Yoshihiro
    Okamoto, Yoshihiro
    Asano, Hiroyuki
    Ishibashi-Ueda, Hatsue
    Zhou, Yue-Min
    Hayashida, Kyoko
    Matsuhashi, Toshio
    Seiji, Kazumasa
    Sato, Akihiro
    Yamada, Takayuki
    Takahashi, Shoki
    Ishibashi, Tadashi
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 83B (02) : 345 - 353