Effect of Stator Winding Connection of Five-Phase Induction Machines on Torque Ripples Under Open Line Condition

被引:35
|
作者
Abdel-Khalik, Ayman S. [1 ,2 ]
Ahmed, Shehab [3 ]
Elserougi, Ahmed A. [1 ]
Massoud, Ahmed M. [1 ,4 ]
机构
[1] Univ Alexandria, Dept Elect Engn, Fac Engn, Alexandria 21544, Egypt
[2] Spiretronic LLC, Houston, TX 77095 USA
[3] Texas A&M Univ Qatar, Doha 23874, Qatar
[4] Qatar Univ, Dept Elect Engn, Doha 2713, Qatar
关键词
Dynamic model; fault tolerant; induction machine (IM); multiphase machine; open-loop control; optimal current control; pentagon connection; stator winding configuration; steady-state model; torque ripples; MOTOR; FAULT;
D O I
10.1109/TMECH.2014.2303254
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
One of the main challenges in designing high-power drive systems is the quality of the developed torque. High-torque-ripple magnitudes result in serious vibration and acoustic noise problems that affect the lifetime of a drive train. Multiphase machines intrinsically offer the torque with higher quality and are also being promoted for their high fault tolerant capability when compared with their three-phase counterparts. During open-phase conditions, the induced nonfundamental sequence current components have a detrimental effect on the machine performance especially under open-loop control. Although optimal current control is usually employed to ensure certain optimization criterion, such as minimizing torque ripples, optimizing flux distribution, or minimizing copper loss, are met, it usually entails a sophisticated current controller. This paper studies the effect of a stator winding connection of a five-phase induction machine on the induced torque ripples. Two possible connections, namely, star and pentagon connections are compared under healthy as well as fault conditions with one-line open. The comparison is conducted using both finite-element simulation and experimental results using a 1.5-Hp five-phase prototype induction machine. The comparison shows that the pentagon connection reduces the machine-induced torque ripples and improves the overall machine performance under fault conditions.
引用
收藏
页码:580 / 593
页数:14
相关论文
共 50 条
  • [1] Effect of Stator Winding Connection on Performance of Five-Phase Induction Machines
    Abdel-Khalik, Ayman S.
    Morsy, Ahmed S.
    Ahmed, Shehab
    Massoud, Ahmed M.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (01) : 3 - 19
  • [2] Influence of mixed winding arrangements on torque ripples of five-phase induction machines
    Muteba, Mbika
    Nicolae, Dan Valentine
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2017, 151 : 154 - 165
  • [3] Fault-Tolerance of Five-Phase Induction Machines with Mixed stator winding Layouts: Torque Ripple Analysis
    Muteba, M.
    Nicolae, D. V.
    [J]. 2015 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2015, : 308 - 314
  • [4] Control of Five-Phase Dual Stator-Winding Induction Generator With an Open Phase
    Xu, Haijun
    Huang, Wenxin
    Bu, Feifei
    Liu, Haozhe
    Lin, Xiaogang
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (01) : 696 - 706
  • [5] Torque Ripple Reduction in Five-Phase Induction Machines Using Mixed Winding Configurations
    Muteba, M.
    Jimoh, A. A.
    Nicolae, D.
    [J]. 2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 512 - 518
  • [6] Dynamic Modeling of a Five-Phase Induction Machine With a Combined Star/Pentagon Stator Winding Connection
    Abdel-Khalik, Ayman S.
    Ahmed, Shehab
    Massoud, Ahmed M.
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) : 1645 - 1656
  • [7] Predictive Torque Control of Five-Phase Open-Ended Winding Induction Motor
    Rayavarapu, Naresh
    Devabhaktuni, Swati
    Reddy, C. Venkata Subba
    [J]. RECENT ADVANCES IN POWER ELECTRONICS AND DRIVES, VOL 2, EPREC 2023, 2024, 1139 : 279 - 296
  • [8] Induction distribution of five-phase induction machines under open-phase fault
    Pereira, Luis Alberto
    Nicol, Guilherme
    Alves Pereira, Luis Fernando
    Perin, Matheus
    [J]. ISA TRANSACTIONS, 2020, 96 : 468 - 478
  • [9] Steady-State Equivalent Circuit of Five-Phase Induction Machines With Different Stator Connections Under Open-Line Conditions
    Abdel-Khalik, Ayman Samy
    Ahmed, Shehab
    Massoud, Ahmed M.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (08) : 4651 - 4662
  • [10] Effect of Stator Winding Configurations on Operation of Converter Fed Five-Phase Induction Machine
    Chomat, M.
    Schreier, L.
    Bendl, J.
    [J]. 2015 INTERNATIONAL CONFERENCE ON ELECTRICAL DRIVES AND POWER ELECTRONICS (EDPE), 2015, : 488 - 496