Ultrasensitive label-free electrochemical biosensor for detecting linear microcystin-LR using degrading enzyme MlrB as recognition element

被引:13
|
作者
Li, Yanfang [1 ]
Si, Sisi [1 ]
Huang, Feiyu [3 ]
Wei, Jia [3 ]
Dong, Shengyi [4 ]
Yang, Fei [2 ]
Li, Huimin [1 ]
Liu, Song [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, Inst Chem Biol & Nanomed ICBN, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
[2] Univ South China, Sch Publ Hlth, Hunan Prov Key Lab Typ Environm Pollut & Hlth Haz, Hengyang 421001, Peoples R China
[3] Cent South Univ, Xiangya Sch Publ Hlth, Hunan Prov Key Lab Clin Epidemiol, Changsha 410078, Peoples R China
[4] Hunan Univ, Coll Chem & Chem Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Linear microcystin-LR; MlrB; Electrochemical biosensor; Multi-walled carbon nanotube; Square wave voltammetry; SENSITIVE DETECTION; IMMUNOSENSOR; NANOPARTICLES; GRAPHENE; CHROMATOGRAPHY; PLATFORM;
D O I
10.1016/j.bioelechem.2021.108000
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A label-free electrochemical biosensor was firstly constructed to detect linear microcystin-LR (L-MC-LR) with high sensitivity. Degradation enzyme MlrB was used as recognition element for specific recognition of L-MC-LR. The electrode was modified with -COOH functionalized multi-walled carbon nanotube to increase the specific surface area and improve the conductivity, which was then applied to immobilize MlrB. The electrochemical signal was changed with the reaction between MlrB and L-MC-LR, which was recorded by using square wave voltammetry. The electrochemical biosensor showed superior sensitivity, with a dynamic range of 1 pg/mL to 100 ng/mL and a detection limit of 0.127 pg/mL. Moreover, the fabricated electrochemical biosensor exhibited excellent specificity toward L-MC-LR in real water samples. The concentrations of spiked L-MC-LR were 0.100, 5.00, 50.0 ng/mL, and the recovery rates were 95.0-104% with relative standard deviation (RSD) of 0.900-2.30% and 74.0-93.0% with RSD of 2.303.50% in lake water and tap water, respectively. Furthermore, the selectivity, reproducibility, and stability demonstrated the potential of degradation enzymes as recognition element in detection of cyanotoxins. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of microcystin-LR in water by a label-free aptamer based electrochemical impedance biosensor
    Lin, Zhenyu
    Huang, Huiming
    Xu, Yixiang
    Gao, Xiaoyao
    Qiu, Bin
    Chen, Xi
    Chen, Guonan
    TALANTA, 2013, 103 : 371 - 374
  • [2] Label-free aptamer-based detection of microcystin-LR using a microcantilever array biosensor
    Zhang, Guanping
    Li, Chao
    Wu, Shangquan
    Zhang, Qingchuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 42 - 47
  • [3] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    YunXia Hu
    Fang Shang
    Yuan Liu
    Sui Wang
    Yufang Hu
    Zhiyong Guo
    Chemical Papers, 2018, 72 : 71 - 79
  • [4] A label-free electrochemical immunosensor based on multi-functionalized graphene oxide for ultrasensitive detection of microcystin-LR
    Hu, YunXia
    Shang, Fang
    Liu, Yuan
    Wang, Sui
    Hu, Yufang
    Guo, Zhiyong
    CHEMICAL PAPERS, 2018, 72 (01) : 71 - 79
  • [5] Label-Free Immunosensor for the Determination of Microcystin-LR in Water
    Almeida de Oliveira, Ravila
    Zanato, Nicole
    Cruz Vieira, Iolanda
    ELECTROANALYSIS, 2020, 32 (10) : 2166 - 2173
  • [6] Label-free immunosensing of microcystin-LR using a gold electrode modified with gold nanoparticles
    Ping Tong
    Shurong Tang
    Yu He
    Yanhong Shao
    Lan Zhang
    Guonan Chen
    Microchimica Acta, 2011, 173 : 299 - 305
  • [7] Label-free immunosensing of microcystin-LR using a gold electrode modified with gold nanoparticles
    Tong, Ping
    Tang, Shurong
    He, Yu
    Shao, Yanhong
    Zhang, Lan
    Chen, Guonan
    MICROCHIMICA ACTA, 2011, 173 (3-4) : 299 - 305
  • [8] A SIMPLE, HIGHLY SENSITIVE, AND LABEL-FREE IMPEDIMETRIC IMMUNOSENSOR FOR DETECTION OF MICROCYSTIN-LR IN WATER
    Sun, Xiulan
    Shi, Hui
    Wang, Hongxin
    Xiao, Liwen
    Li, Luning
    ANALYTICAL LETTERS, 2010, 43 (04) : 533 - 544
  • [9] Microcystin-LR label-free immunosensor based on exfoliated graphite nanoplatelets and silver nanoparticles
    Zanato, Nicole
    Talamini, Lucas
    Silva, Tania Regina
    Vieira, Iolanda Cruz
    TALANTA, 2017, 175 : 38 - 45
  • [10] Label-Free Voltammetric Aptasensor for the Sensitive Detection of Microcystin-LR Using Graphene-Modified Electrodes
    Eissa, Shimaa
    Ng, Andy
    Siaj, Mohamed
    Zourob, Mohammed
    ANALYTICAL CHEMISTRY, 2014, 86 (15) : 7551 - 7557