Detection of immunoglobulin G antibodies to Toxoplasma gondii: Evaluation of two commercial immunoassay systems

被引:6
|
作者
Tekkesin, Nilgun [1 ]
Keskin, Kenan [2 ]
Kilinc, Cumhur [1 ]
Orgen, Nuray [1 ]
Moto, Kaya [1 ]
机构
[1] Mem Hosp, Clin Lab, Dept Biochem, TR-34385 Istanbul, Turkey
[2] Mem Hosp, Clin Lab, Dept Microbiol & Dis, TR-34385 Istanbul, Turkey
关键词
Anti-T gondii IgG; Immunofluorescent assay; Toxo IgG; FELDMAN DYE TEST; DIAGNOSIS; IGG; ASSAY; IMX; INFECTION; PREGNANCY; AVIDITY;
D O I
10.1016/j.jmii.2011.01.005
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background: Toxoplasmosis is a disease, which can cause severe congenital infection and is normally diagnosed by the detection of Toxoplasma gondii (T gondii)-specific antibodies in the serum of infected patients. Several different tests allow to distinguish recent from past infections and to quantify anti-T gondii-specific IgG, and the results can be used as markers for a chronic or recently seroconverted toxoplasma. Methods: In the present study, the recent Cobas 6000 Toxo IgG assay (Roche Diagnostics, Indianapolis, IN, USA) for the serological diagnosis of toxoplasmosis was compared with the Axsym Toxo IgG assay (Abbott Laboratories, Diagnostics Division, Abbott Park, IL, USA) employing a panel of negative, low- or high-reactive serum samples that were selected after routine screening in a laboratory of clinical analyses. Results: The overall agreement between two methods was 99% (r = 0.99, p < 0.001). Of 91 analyzed samples, only one presented discrepant result, being positive in the Cobas 6000 Toxo IgG assay and negative in the Axsym Toxo IgG assay. By using an immunofluorescent assay as a confirmation test, this positive result was assayed to be negative. Conclusions: Both assays performed in each analyzer were proven to be fast and fully automated procedures for reproducible measurement of IgG antibodies to Tgondii. The new method, used for the determination of anti-Tgondii IgG antibodies, should be evaluated with a further analysis with increased number of serum samples to get a broad performance of this newer test. Copyright (C) 2011, Taiwan Society of Microbiology. Published by Elsevier Taiwan LLC. All rights reserved.
引用
下载
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [1] Detection of immunoglobulin G (IgG) and IgM antibodies to Toxoplasma gondii: Evaluation of four commercial immunoassay systems
    Hofgartner, WT
    Swanzy, SR
    Bacina, RM
    Condon, J
    Gupta, M
    Matlock, PE
    Bergeron, DL
    Plorde, JJ
    Fritsche, TR
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) : 3313 - 3315
  • [2] COMPARISON OF A COMMERCIAL ENZYME-IMMUNOASSAY AND AN IMMUNOBLOT TECHNIQUE FOR DETECTION OF IMMUNOGLOBULIN A ANTIBODIES TO TOXOPLASMA-GONDII
    GROSS, U
    BOHNE, W
    SCHRODER, J
    ROOS, T
    HEESEMANN, J
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1993, 12 (08) : 636 - 639
  • [3] Evaluation of six commercial kits for detection of human immunoglobulin M antibodies to Toxoplasma gondii
    Wilson, M
    Remington, JS
    Clavet, C
    Varney, G
    Press, C
    Ware, D
    Herman, CL
    Shively, RG
    Simms, TE
    Hansen, S
    Gaffey, CM
    Nutter, CD
    Langone, JJ
    McCracken, J
    Staples, B
    JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (12) : 3112 - 3115
  • [4] Antenatal screening for hepatitis B and antibodies to Toxoplasma gondii and rubella virus:: Evaluation of two commercial immunoassay systems
    Diepersloot, RJA
    Dunnewold-Hoekstra, H
    Kruit-Den Hollander, J
    Vlaspolder, F
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (04) : 785 - 787
  • [5] MULTICENTER EVALUATION OF A NEW COMMERCIAL ASSAY FOR DETECTION OF IMMUNOGLOBULIN-M ANTIBODIES TO TOXOPLASMA-GONDII
    LUYASU, V
    ROBERT, AR
    SCHAEFER, L
    MACIOSZEK, J
    CHRETIEN, MC
    VOCKEL, A
    BESSIERES, MH
    CIMON, B
    DYKE, J
    CANAVAGGIO, M
    GIPSON, R
    GOULLIER, A
    JANITSCHKE, K
    MORIN, O
    PARRI, F
    PERRIN, L
    REITEROWONA, I
    SEITZ, HM
    SMILOVICI, W
    THULLIEZ, P
    ZUFFEREY, J
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1995, 14 (09) : 787 - 793
  • [6] EVALUATION OF IMMUNOBLOTTING FOR THE DETECTION OF TOXOPLASMA-GONDII IMMUNOGLOBULIN-M ANTIBODIES
    VERHOFSTEDE, C
    VANRENTERGHEM, L
    PLUM, J
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1990, 9 (11) : 835 - 837
  • [7] EVALUATION OF A RAPID SCREENING IMMUNOASSAY FOR ANTIBODIES TO TOXOPLASMA-GONDII
    SMITH, SB
    REPETTI, CF
    JOURNAL OF CLINICAL MICROBIOLOGY, 1987, 25 (11) : 2207 - 2208
  • [8] Evaluation of the immunoblotting for the detection of immunoglobulin G Toxoplasma antibodies in immunocompetent patients
    Khammari, I.
    Saghrouni, F.
    Bougmiza, I.
    Gheith, S.
    Ben Abdejlil, J.
    Yaacoub, A.
    Boukadida, J.
    Babba, H.
    Ben Said, M.
    PATHOLOGIE BIOLOGIE, 2012, 60 (03): : 160 - 165
  • [9] EVALUATION OF THE FIAX SEMIAUTOMATIC FLUORESCENT IMMUNOASSAY SYSTEM FOR THE DETECTION OF IGG ANTIBODIES TO TOXOPLASMA-GONDII
    CARLSON, LG
    PLORDE, JJ
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1983, 1 (03) : 233 - 239
  • [10] AN ENZYME-IMMUNOASSAY FOR IMMUNOGLOBULIN-M ANTIBODIES TO TOXOPLASMA-GONDII WHICH IS NOT AFFECTED BY RHEUMATOID-FACTOR OR IMMUNOGLOBULIN-G ANTIBODIES
    LIN, TM
    CHINSEE, MW
    HALBERT, SP
    JOSEPH, JM
    JOURNAL OF CLINICAL MICROBIOLOGY, 1986, 23 (01) : 77 - 82