Uncertainties of measurements in radiation protection

被引:0
|
作者
Steurer, A [1 ]
Schmitzer, C
Gruen, K
机构
[1] ARC Seibersdorf Res GmbH, A-2444 Seibersdorf, Austria
[2] Oesterreich Normungsinst, A-1020 Vienna, Austria
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
On September 1st, 2001, the Austrian standard OENORM S 52551 with the title "Uncertainties of measurements and limiting values in radiation protection - Part 1: Basics" was published. A part 2 of the standard with the subtitle "Assessment of measurements with regard to limiting values" was published on April 1st, 2002. Part I of the standard is a consequent application of the "Guide to the expression of uncertainty in measurement" (GUM) for measurements in radiation protection. It contains a summary of the most important definitions and mathematical methods, which are relevant for measurements in radiation protection. An important prerequisite is the standardisation of the coverage factor k = 1 for measurements in radiation protection. Finally, the use of the standard is demonstrated by a detailed example there (dose rate meter). First, the uncertainty of a dose rate meter is stated, using only information on tolerances available e. g. from instrument specifications. Additionally, the strategies to reduce the uncertainty and the necessary detailed knowledge of the dose rate meter are demonstrated. Part 2 of the standard gives a simple concept for interpretation of limits using the uncertainties calculated based on part 1 of the standard.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 50 条
  • [1] Uncertainties of measurements in radiation protection
    Steurer, A.
    Schmitzer, C.
    Gruen, K.
    [J]. KERNTECHNIK, 2022, 68 (04) : 168 - 171
  • [2] Uncertainties in radiation measurements
    Thomas, D
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (04) : 343 - 345
  • [3] Concerning radiation protection and radiation protection measurements
    Jaeger, R
    Zimmer, KG
    [J]. PHYSIKALISCHE ZEITSCHRIFT, 1941, 42 : 25 - 35
  • [4] Deviating measurements in radiation protection - Legal assessment of deviations in radiation protection measurements
    Hoegl, A
    [J]. ATW-INTERNATIONALE ZEITSCHRIFT FUR KERNENERGIE, 1996, 41 (07): : 474 - 477
  • [5] Fourier-transform radiation thermometry: measurements and uncertainties
    Dufour, PC
    Rowell, NL
    Steele, AG
    [J]. APPLIED OPTICS, 1998, 37 (25): : 5923 - 5931
  • [6] Calculation of the detection limit in radiation measurements with systematic uncertainties
    Kirkpatrick, J. M.
    Russ, W.
    Venkataraman, R.
    Young, B. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 306 - 310
  • [7] Radiation measurements and standards needs for radiation protection.
    Yoder, RC
    [J]. HEALTH PHYSICS, 2005, 89 (01): : S79 - S79
  • [8] APPLICATION OF MICROPROCESSORS TO RADIATION PROTECTION MEASUREMENTS
    ZAPPE, D
    ROSEL, G
    MELDE, C
    [J]. KERNENERGIE, 1982, 25 (08): : 313 - 317
  • [9] A SIMPLE INSTRUMENT FOR RADIATION PROTECTION MEASUREMENTS
    LORENTZON, L
    WAHLBERG, T
    [J]. ACTA RADIOLOGICA, 1950, 33 (3-4) : 305 - 310
  • [10] MICRODOSIMETRIC MEASUREMENTS FOR RADIOTHERAPY AND RADIATION PROTECTION
    NODA, Y
    MARUYAMA, T
    FUKUHISA, K
    KANAI, T
    KUMAMOTO, Y
    SHIRAGAI, A
    YAMAGUCHI, H
    [J]. JOURNAL OF RADIATION RESEARCH, 1983, 24 (01) : 82 - 82