Application of Focused Ultrasound-Assisted Extraction to the Determination of Persistent Organic Pollutants (POPs) in Soil Samples

被引:15
|
作者
Flores-Ramirez, R. [1 ]
Medellin-Garibay, S. E. [3 ]
Castillo, C. G. [2 ]
Ilizaliturri-Hernandez, C. A. [1 ]
Zuki-Orozco, B. A. [1 ]
Batres-Esquivel, L. [1 ]
Diaz-Barriga, F. [1 ]
机构
[1] Univ Autonoma San Luis Potosi, Ctr Nacl Bioanal CENBIOS, CIACYT, Ctr Invest Aplicada Ambiente & Salud, San Luis Potosi 78210, SLP, Mexico
[2] Univ Autonoma San Luis Potosi, Fac Med, Dept Bioquim, San Luis Potosi 78210, SLP, Mexico
[3] Univ Complutense Madrid, Fac Farm, E-28040 Madrid, Spain
关键词
Persistent organic pollutants; Focused ultrasound extraction; Soil; GC-MS-EI; SOLID-LIQUID EXTRACTION; POLYCHLORINATED-BIPHENYLS; MASS-SPECTROMETRY; ORGANOCHLORINE PESTICIDES; MEXICAN CHILDREN; SURFACE SOILS; CHROMATOGRAPHY; SEDIMENT; EXPOSURE;
D O I
10.1007/s00128-015-1545-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and rapid focused ultrasound extraction (FU) based method is presented for the determination of persistent organic pollutants (POPs) in soil using a gas chromatography coupled to a mass detector with electron impact ionization. The main experimental parameters affecting the FU step have been optimized by applying a PERMANOVA and PCO analysis allowing us to obtain a maximum amount of information with a minimum number of assays. The limits of detection for POPs fell within the 0.9-6.8 ng/g d.w. interval; a linear method was used with correlation coefficients (r) higher than 0.99. Recovery percentages at low concentrations (25 ng/g d.w.) were 75.8 %-110 %, and at high concentrations (75 ng/g d.w.) 82.3 %-109 %; the evaluated precision as RSD% of repeatability and reproducibility were within a range of 0.5 %-11 % and 0.3 %-18 %, respectively.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 50 条
  • [1] Application of Focused Ultrasound-Assisted Extraction to the Determination of Persistent Organic Pollutants (POPs) in Soil Samples
    R. Flores-Ramírez
    S. E. Medellín-Garibay
    C. G. Castillo
    C. A. Ilizaliturri-Hernández
    B. A. Zuki-Orozco
    L. Batres-Esquivel
    F. Díaz-Barriga
    Bulletin of Environmental Contamination and Toxicology, 2015, 95 : 207 - 214
  • [2] Application of ultrasound-assisted extraction to the determination of contaminants in food and soil samples
    Tadeo, Jose L.
    Sanchez-Brunete, Consuelo
    Albero, Beatriz
    Garcia-Valcarcel, Ana I.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (16) : 2415 - 2440
  • [3] Ultrasound-assisted extraction methods for the determination of organic contaminants in solid and liquid samples
    Perez, Rosa A.
    Albero, Beatriz
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 166
  • [4] Application of Focused Ultrasound-Assisted Extraction for the Quantification of Persistent Organic Pollutions in Liver Tissue of Giant Toad (Rhinella marina)
    Flores-Ramirez, R.
    Espinosa-Reyes, G.
    Cilia-Lopez, V. G.
    Gonzalez-Mille, D. J.
    Rodriguez-Aguilar, M.
    Diaz de Len-Martinez, L.
    Diaz-Barriga, F.
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2017, 98 (02) : 204 - 211
  • [5] Application of Focused Ultrasound-Assisted Extraction for the Quantification of Persistent Organic Pollutions in Liver Tissue of Giant Toad (Rhinella marina)
    R. Flores-Ramírez
    G. Espinosa-Reyes
    V. G. Cilia-López
    D. J. González-Mille
    M. Rodríguez-Aguilar
    L. Díaz de León-Martínez
    F. Díaz-Barriga
    Bulletin of Environmental Contamination and Toxicology, 2017, 98 : 204 - 211
  • [6] Determination of persistent organic pollutants (POPs) using accelerated solvent extraction (ASEO)
    Peterson, J
    Henderson, S
    Richter, B
    LC GC EUROPE, 2005, : 8 - 8
  • [7] Application of Ultrasound-Assisted Supercritical Extraction to Soil Remediation
    Castelo-Grande, Teresa
    Augusto, Paulo A.
    Estevez, Angel M.
    Barbosa, Domingos
    CHEMICAL ENGINEERING & TECHNOLOGY, 2017, 40 (04) : 691 - 698
  • [8] Ultrasound-assisted extraction of cadmium in environmental samples for ETAAS determination
    Brasil, JL
    Lima, EC
    Veses, RC
    Tisott, MM
    ATOMIC SPECTROSCOPY, 2004, 25 (02) : 94 - 101
  • [9] Application of micro-solid-phase extraction for the determination of persistent organic pollutants in tissue samples
    Basheer, Chanbasha
    Narasirnhan, Kothandaraman
    Yin, Meihui
    Zhao, Changqing
    Choolani, Mahesh
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1186 (1-2) : 358 - 364
  • [10] Determination of environmental persistent organic pollutants (POPs) in hair samples from wild terrestrial mammals
    Iatrou, E.
    Tzatzarakis, M. N.
    Vakonaki, E. K.
    Papachristou, S.
    Renieri, E.
    Golokhvast, K.
    Seryodkin, I.
    Tsygankov, V.
    Valerii, R.
    Tsatsakis, A. M.
    TOXICOLOGY LETTERS, 2018, 295 : S262 - S262