BABAR CsI calorimeter design and first beam test results

被引:0
|
作者
Brose, J
机构
[1] Inst. fur Kern- und Teilchenphysik, Technische Universität Dresden
关键词
D O I
10.1016/0168-9002(96)00684-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The BABAR detector at the PEP-II B-factory at SLAC is designed to measure CP violation in the decays of B mesons. In order to meet the physics aims of the experiment the target energy resolution for photons at a polar angle of 90 degrees is: sigma(E)/E = (1%/(4) root/E[GeV]) + 1.2%. This requires a minimum equivalent noise energy of about 150 keV per crystal. using two 1 x 2 cm(2) photodiodes for direct readout of full-size crystals a photoelectron yield of about 8000 e(-)/MeV and equivalent noise energies below 100 keV were obtained in the laboratory. A first beam test using a 5 x 5 array of crystals was performed in the fall of 1995 at an electron/pion beam at PSI. Data were collected at different energies between 100 MeV and 400 MeV allowing the determination of energy and angular resolution as a function of energy, impact position and angle of incidence, Results of a first analysis of these data are presented.
引用
收藏
页码:495 / 498
页数:4
相关论文
共 50 条
  • [1] Results from the BABAR electromagnetic calorimeter beam test
    Barlow, RJ
    Bernet, R
    Bowdery, CK
    Brose, J
    Champion, T
    Dahlinger, G
    Dauncey, P
    Eckstein, P
    Eigen, G
    Freytag, D
    Fry, J
    Geddes, NI
    Hertzbach, SS
    Ivanchenko, V
    Jessop, C
    Johnson, D
    King, M
    Lorenz, E
    Marsiske, H
    McMahon, S
    Nicholson, H
    Reidy, J
    Schindler, R
    Schubert, KR
    Schwierz, R
    Scott, I
    Seitz, R
    Silagadze, Z
    Spaan, B
    Stoker, DP
    Tetteh-Lartey, E
    Waldi, R
    Wisniewski, WJ
    Wuest, CR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 420 (1-2): : 162 - 180
  • [2] Beam test results of a CsI calorimeter matrix element
    Missaghian, J.
    Hurley, F.
    Bashkirov, V.
    Colby, B.
    Rykalin, V.
    Kachigiun, S.
    Fusi, D.
    Schulte, R.
    Mckinney, F. Martinez
    Sadrozinski, H.
    Penfold, S.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [3] The BABAR CsI(Tl) calorimeter
    Manzin, G
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 454 - 458
  • [4] Beam test of a prototype CsI calorimeter
    Kessler, RS
    Roodman, A
    Shawhan, P
    Solomey, N
    Winstein, B
    Hansen, S
    Nguyen, H
    Ray, R
    Tschirhart, R
    Whitmore, J
    Nakaya, T
    Lindgren, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (03): : 653 - 665
  • [5] Calibration of the BABAR CsI (Tl) Calorimeter
    Marks, Joerg
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [6] The CsI(Tl) calorimeter of the BaBar detector
    Bauer, JM
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 72 - 81
  • [7] Design, construction and first operation of the large CsI calorimeter for the BABAR detector at the PEP-II storage rings
    Allison, J
    Baird, K
    Barlow, RJ
    Bauer, JM
    Bernet, R
    Brook, CK
    Bowdery, CK
    Brandt, T
    Brooks, A
    Brose, J
    Button-Shafer, J
    Camanzi, B
    Champion, T
    Clark, P
    Cremaldi, L
    Dahlinger, G
    Dauncey, PD
    Krause, R
    Futterschneider, H
    Doyle, E
    Eckstein, P
    Eigen, G
    Eisner, G
    Flood, K
    Foster, B
    Freytag, D
    Fry, JR
    Fujino, D
    Gabathuler, E
    Gaede, F
    Geddes, NI
    Green, MG
    Hanson, J
    Harrison, PF
    Hauke, A
    Hertzbach, SS
    Hitlin, DG
    Ivanchenko, V
    Jessop, CP
    Kay, J
    King, M
    Koch, H
    Kocain, M
    Kofler, R
    Korol, A
    Kunze, M
    Langenegger, U
    Lewandowski, B
    Lidbury, J
    LoSsecco, JM
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 6 - 13
  • [8] THE CALICE TILE HADRON CALORIMETER PROTOTYPE WITH SIPM READOUT: DESIGN, CONSTRUCTION AND FIRST TEST BEAM RESULTS
    Wattimena, N.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 381 - 385
  • [9] Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes
    Aidala, C. A.
    Bailey, V.
    Beckman, S.
    Belmont, R.
    Biggs, C.
    Blackburn, J.
    Boose, S.
    Chiu, M.
    Connors, M.
    Desmond, E.
    Franz, A.
    Haggerty, J. S.
    He, X.
    Higdon, M. M.
    Huang, J.
    Kauder, K.
    Kistenev, E.
    LaBounty, J.
    Lajoie, J. G.
    Lenz, M.
    Lenz, W.
    Li, S.
    Loggins, V. R.
    Mannel, E. J.
    Majoros, T.
    McCumber, M. P.
    Nagle, J. L.
    Phipps, M.
    Pinkenburg, C.
    Polizzo, S.
    Pontieri, C.
    Purschke, M. L.
    Putschke, J.
    Sarsour, M.
    Rinn, T.
    Ruggiero, R.
    Sen, A.
    Sickles, A. M.
    Skoby, M. J.
    Smiga, J.
    Sobel, P.
    Stankus, P. W.
    Stoll, S.
    Sukhanov, A.
    Thorsland, E.
    Toldo, F.
    Towell, R. S.
    Ujvari, B.
    Vazquez-Carson, S.
    Woody, C. L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (12) : 2901 - 2919
  • [10] First beam test on a BSO electromagnetic calorimeter
    Shimizu, H
    Miyahara, F
    Hariu, H
    Hayakawa, T
    Ishikawa, T
    Itaya, A
    Iwata, T
    Kinoshita, T
    Moriya, M
    Nakabayashi, T
    Sasaki, T
    Tajima, Y
    Takita, S
    Yamamoto, M
    Yamazaki, H
    Yoshida, HY
    Yoshida, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 258 - 266