Transcutaneous measurement of bilirubin in Turkish newborns: comparison with total serum bilirubin

被引:0
|
作者
Kaynak-Turkmen, Munevver [1 ]
Aydogdu, S. Ayvaz [1 ]
Gokbulut, Cengiz [3 ]
Yenisey, Cigdem [2 ]
Soz, Omer [1 ]
Cetinkaya-Cakmak, Bilin [1 ]
机构
[1] Adnan Menderes Univ, Fac Med, Dept Pediat, Aydin, Turkey
[2] Adnan Menderes Univ, Fac Med, Dept Biochem, Aydin, Turkey
[3] Adnan Menderes Univ, Fac Vet Med, Dept Pharmacol & Toxicol, Aydin, Turkey
关键词
high performance liquid chromatography; jaundice; transcutaneous bilirubin measurement; TRANS-CUTANEOUS BILIRUBINOMETRY; HYPERBILIRUBINEMIA; BILICHECK; AGREEMENT; RISK;
D O I
暂无
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Routine use of transcutaneous bilirubin (TcB) measurement in the newborn nursery could reduce costs, readmission rates for hyperbilirubinemia and the need for total serum bilirubin (TSB) measurements. The aim of this study was to examine the correlation between TcB measurement, as performed using BiliCheck, and TSB, measured with high-pressure liquid chromatography (HPLC) and with standard laboratory methods, and to determine the TcB cutoff points with desirable sensitivity and specificity values for various clinically relevant TSB levels by HPLC. Fifty-four infants of >= 30 weeks of gestational age were enrolled in the study. Near simultaneous blood collection for TSB analysis by three methods - bedside bilirubinometer, diazo method and HPLC - and TcB measurement were performed. There was good correlation between TcB and HPLC-bilirubin (B) (r=0.85), TSB by bilirubinometer and HPLC-B (r=0.91) and TSB by diazo method and HPLC-B (r=0.91). The cut-off limits providing a sensitivity of 100% for TcB measurements were TcB >= 9 mg/dl for HPLC-B >17 mg/dl and TcB >= 8 mg/dl for HPLC-B >15 mg/dl and HPLC-B >13 mg/dl. Despite having good correlation with HPLC, BiliCheck showed worse performance than bilirubinometer and diazo method at various clinically relevant cut-off values. Since BiliCheck required relatively lower thresholds with false-positive results for having a sensitivity of 100%, it cannot be recommended as a complete substitute for serum bilirubin measurements.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 50 条
  • [1] Comparison of transcutaneous and total serum bilirubin measurement in Turkish newborns
    Simsek, Fatih Mehmet
    Narter, Fatma
    Erguven, Muferet
    [J]. TURKISH JOURNAL OF PEDIATRICS, 2014, 56 (06) : 612 - 617
  • [2] Transcutaneous Bilirubin Measurement Correlation with Total Serum Bilirubin in Healthy Newborns
    Shihadeh, Manal D.
    Kheyami, Deena
    Al Jufairi, Mona
    Jaradat, Ahmed A.
    Al Ansari, Eman M.
    [J]. BAHRAIN MEDICAL BULLETIN, 2016, 38 (04) : 208 - 210
  • [3] Transcutaneous bilirubinometry versus total serum bilirubin measurement for newborns
    Okwundu, Charles I.
    Olowoyeye, Abiola
    Uthman, Olalekan A.
    Smith, Johan
    Wiysonge, Charles S.
    Bhutani, Vinod K.
    Fiander, Michelle
    Gautham, Kanekal S.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2023, (05):
  • [4] Comparison between Bilistick System and transcutaneous bilirubin in assessing total bilirubin serum concentration in jaundiced newborns
    C Greco
    I F Iskander
    D M Akmal
    S Z El Houchi
    D A Khairy
    G Bedogni
    R P Wennberg
    C Tiribelli
    C D Coda Zabetta
    [J]. Journal of Perinatology, 2017, 37 : 1028 - 1031
  • [5] Comparison between Bilistick System and transcutaneous bilirubin in assessing total bilirubin serum concentration in jaundiced newborns
    Greco, C.
    Iskander, I. F.
    Akmal, D. M.
    El Houchi, S. Z.
    Khairy, D. A.
    Bedogni, G.
    Wennberg, R. P.
    Tiribelli, C.
    Zabetta, C. D. Coda
    [J]. JOURNAL OF PERINATOLOGY, 2017, 37 (09) : 1028 - 1031
  • [6] Simultaneous measurement of total transcutaneous bilirubin on forehead and chest as a predictive model for total serum bilirubin in premature and term newborns
    Esther Martinez-Mercado, Maria
    Fernando Torres-Bernal, Luis
    Gongora-Ortega, Javier
    del Rosario Sanchez-Ortiz, Maria
    Guerrero-Diaz de Leon, Jose Antonio
    [J]. ACTA PEDIATRICA DE MEXICO, 2014, 35 (02): : 106 - 110
  • [7] Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in preterm neonates receiving phototherapy
    Pendse, Amruta
    Jasani, Bonny
    Nanavati, Ruchi
    Kabra, Nandkishor
    [J]. INDIAN PEDIATRICS, 2017, 54 (08) : 641 - 643
  • [8] Comparison of transcutaneous bilirubin measurement with total serum bilirubin levels in preterm neonates receiving phototherapy
    Amruta Pendse
    Bonny Jasani
    Ruchi Nanavati
    Nandkishor Kabra
    [J]. Indian Pediatrics, 2017, 54 : 641 - 643
  • [9] Concurrent measurement of total transcutaneous bilirubin over forehead and sternum as predictive model for total serum bilirubin in premature and term newborns
    Esther Martinez-Mercado, Maria
    Fernando Torres-Bernal, Luis
    Gongora-Ortega, Javier
    del Rosario Sanchez-Ortiz, Maria
    Guerrero-Diaz de Leon, Jose Antonio
    [J]. ACTA PEDIATRICA DE MEXICO, 2014, 35 (02): : 118 - 124
  • [10] Validation of a transcutaneous bilirubin meter in Mongolian neonates: comparison with total serum bilirubin
    Akahira-Azuma, Moe
    Yonemoto, Naohiro
    Ganzorig, Battsengel
    Mori, Rintaro
    Hosokawa, Shinichi
    Matsushita, Takeji
    Bavuusuren, Bayasgalantai
    Shonkhuuz, Enkhtur
    [J]. BMC PEDIATRICS, 2013, 13