Validity of Ultrasound Imaging in Measuring Quadriceps Muscle Thickness and Cross-Sectional Area in Patients Receiving Maintenance Hemodialysis

被引:17
|
作者
Sahathevan, Sharmela [1 ]
Khor, Ban-Hock [2 ]
Yeong, Chai Hong [3 ]
Tan, Teik Hin [4 ]
Mohaideen, Abdul Kareem Meera [3 ]
Ng, Hi Ming [3 ]
Ong, Gild Rick [5 ]
Narayanan, Sreelakshmi Sankara [5 ]
Gafor, Abdul Halim Abdul [2 ]
Goh, Bak Leong [6 ]
Bee, Boon Cheak [7 ]
Daud, Zulfitri 'Azuan Mat [8 ]
Chinna, Karuthan [3 ]
Karupaiah, Tilakavati [5 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Hlth Sci, Dietet Program, Kuala Lumpur, Malaysia
[2] Univ Kebangsaan Malaysia, Fac Med, Kuala Lumpur, Malaysia
[3] Taylors Univ, Fac Hlth & Med Sci, Sch Med, Subang Jaya, Selangor, Malaysia
[4] Sunway Med Ctr, Nucl Med Ctr, Petaling Jaya, Selangor, Malaysia
[5] Taylors Univ, Fac Hlth & Med Sci, Sch BioSci, Lakeside Campus 1,Jalan Taylors, Subang Jaya 47500, Selangor, Malaysia
[6] Serdang Hosp, Dept Nephrol, Kajang, Selangor, Malaysia
[7] Selayang Hosp, Dept Nephrol, Batu Caves, Selangor, Malaysia
[8] Univ Putra Malaysia, Fac Med & Hlth Sci, Dept Nutr & Dietet, Seri Kembangan, Selangor, Malaysia
关键词
CT scan; hemodialysis; quadriceps; rectus femoris; ultrasound; vastus intermedius;
D O I
10.1002/jpen.1867
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background Muscle wasting, prevalent in maintenance hemodialysis (HD) patients diagnosed with protein-energy wasting, represents an assessment challenge in the outpatient HD setting. Quadriceps muscle thickness (QMT) and cross-sectional area (CSA) assessment by ultrasound (US) is a potential surrogate measure for muscle wasting. We aimed to determine the validity of US to measure QMT and CSA against the gold standard-computed tomography (CT). Methods Twenty-six patients on HD underwent US and CT scans on the same day, postdialysis session. QMT for rectus femoris (RF) and vastus intermedius (VI) muscles was taken at the midpoint (MID) and two-thirds (2/3) of both thighs and CSA of the RF muscle (RFCSA), respectively. Correlation between US and CT measurements was determined by intraclass correlation coefficient (ICC) and Bland-Altman plot. Results ICC (95% CI) computed between US and CT was 0.94 (0.87-0.97)(,) 0.97 (0.93-0.99)(,) 0.94 (0.87-0.97), 0.94 (0.86-0.97), and 0.92 (0.83-0.97) for RFMID, VIMID, RF2/3, VI2/3, and RFCSA, respectively (all P < 0.001). Bland-Altman analysis indicated no bias in agreement between both methods. Conclusion The US imaging offers a valid and quick bedside assessment approach to assess muscle wasting in HD patients.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [1] Utility of ultrasound in measuring quadriceps muscle thickness in patients receiving maintenance hemodialysis: comprehensive systematic review and meta-analysis
    Elgenidy, Anas
    Sapoor, Shady
    Abdelrhem, Hasnaa
    Ali, Ahmed Said
    Sulliman, Saif
    Hedawy, Sohieb
    Elgharori, Ayman
    Mady, Hassaan
    Hasan, Wisam Abraheem
    Nasser, Mohamed
    Atta, Esraa Abd elaal
    Ghita, Mohamed
    Aly, Mostafa G.
    Zschuentzsch, Jana
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2024, : 192 - 211
  • [2] Assessment of quadriceps muscle cross-sectional area by ultrasound extended-field-of-view imaging
    Noorkoiv, M.
    Nosaka, K.
    Blazevich, A. J.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (04) : 631 - 639
  • [3] Assessment of quadriceps muscle cross-sectional area by ultrasound extended-field-of-view imaging
    M. Noorkoiv
    K. Nosaka
    A. J. Blazevich
    European Journal of Applied Physiology, 2010, 109 : 631 - 639
  • [4] CROSS-SECTIONAL AREA AND FORCE PRODUCTION OF THE QUADRICEPS MUSCLE
    CHAPMAN, SJ
    GRINDROD, SR
    JONES, DA
    JOURNAL OF PHYSIOLOGY-LONDON, 1984, 353 (AUG): : P53 - P53
  • [5] Ultrasound for Measuring the Cross-Sectional Area of Biceps Brachii Muscle in Sarcopenia
    Li, Shumin
    Li, Hanyu
    Hu, Ying
    Zhu, Shaoming
    Xu, Zherong
    Zhang, Qin
    Yang, Yunmei
    Wang, Zhaodi
    Xu, Jia
    INTERNATIONAL JOURNAL OF MEDICAL SCIENCES, 2020, 17 (18): : 2947 - 2953
  • [6] Validity Of Lower Leg Muscle Cross-sectional Area Measurements Using Ultrasound Imaging Compared To MRI
    Johnson, Aaron W.
    Thompson, Christopher
    Violette, Victoria
    Bruening, Dustin A.
    Ridge, Sarah T.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 82 - 82
  • [7] Rehabilitative ultrasound imaging of the supraspinatus muscle: Intra- and interrater reliability of thickness and cross-sectional area
    Schneebeli, Alessandro
    Egloff, Michele
    Giampietro, Amelia
    Clijsen, Ron
    Barbero, Marco
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2014, 18 (02) : 266 - 272
  • [8] Psoas Muscle Cross-sectional Area as a Measure of Whole-body Lean Muscle Mass in Maintenance Hemodialysis Patients
    Morrell, Glen R.
    Ikizler, Talat A.
    Chen, Xiaorui
    Heilbrun, Marta E.
    Wei, Guo
    Boucher, Robert
    Beddhu, Srinivasan
    JOURNAL OF RENAL NUTRITION, 2016, 26 (04) : 258 - 264
  • [9] Validity of ultrasound imaging for intrinsic foot muscle cross-sectional area measurements demonstrated by strong agreement with MRI
    Dallin C Swanson
    Joshua K Sponbeck
    Derek A Swanson
    Conner D Stevens
    Steven P. Allen
    Ulrike H. Mitchell
    James D. George
    Aaron Wayne Johnson
    BMC Musculoskeletal Disorders, 23
  • [10] Validity of ultrasound imaging for intrinsic foot muscle cross-sectional area measurements demonstrated by strong agreement with MRI
    Swanson, Dallin C.
    Sponbeck, Joshua K.
    Swanson, Derek A.
    Stevens, Conner D.
    Allen, Steven P.
    Mitchell, Ulrike H.
    George, James D.
    Johnson, Aaron Wayne
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)