Volume measurement of mango by using 2D ellipse model

被引:0
|
作者
Charoenpong, T [1 ]
Kamhom, P [1 ]
Chamnongthai, K [1 ]
Krairiksh, M [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Dept Elect & Telecommun Engn, Bangkok 10140, Thailand
关键词
mango; volume measurement; 2D ellipse model;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the volume measurement system for mango. Since mango is a fruit that has smooth surface with mostly symmetry shape, we propose to employ two views as input data in order to obtain the volume. The experiments on 30 mangoes in general size showed the root mean squared (RMS) error of volume is 2.098% and 8.420% of the mangoes in dwarf size and high concave-shape. The estimated value strongly agreed with the actual volume.
引用
收藏
页码:1438 / 1441
页数:4
相关论文
共 50 条
  • [1] Method for Volume of Irregular Shape Pellets Estimation Using 2D Imaging Measurement
    Laucka, Andrius
    Andriukaitis, Darius
    Valinevicius, Algimantas
    Navikas, Dangirutis
    Zilys, Mindaugas
    Markevicius, Vytautas
    Klimenta, Dardan
    Sotner, Roman
    Jerabek, Jan
    APPLIED SCIENCES-BASEL, 2020, 10 (08):
  • [2] Analysis of HEMT Multilayered Structures using a 2D Finite Volume Model
    Aminfar, AmirHossein
    Grayeli, Elah Bozorg
    Asheghi, Mehdi
    Goodson, Kenneth E.
    2012 13TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM), 2012, : 224 - 234
  • [3] A moment-of-fluid interface reconstruction using polygon inscribed in ellipse in 2D
    Chiodi, Robert
    Shashkov, Mikhail
    JOURNAL OF COMPUTATIONAL PHYSICS, 2025, 528
  • [4] MEASUREMENT OF PLACENTAL VOLUME USING 2D AND 3D ULTRASOUND AS COMPARED TO MRI - A PILOT STUDY
    Sommerfelt, Silje
    Hillestad, Vigdis
    Higgins, Lucy
    Sagberg, Karianne
    Halle, Tuva
    Gjesdal, Kjell-Inge
    Borthne, Arne Sigurd
    Eskild, Anne
    PLACENTA, 2017, 57 : 292 - 292
  • [5] The Accuracy and Repeatability of Reconstructing Single Bullet Impacts Using the 2D Ellipse Method
    Walters, Miguel
    Liscio, Eugene
    JOURNAL OF FORENSIC SCIENCES, 2020, 65 (04) : 1120 - 1127
  • [6] Prostate segmentation in 2D ultrasound images using image warping and ellipse fitting
    Badiei, Sara
    Salcudean, Septimiu E.
    Varah, Jim
    Morris, W. James
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2, 2006, 4191 : 17 - 24
  • [7] AN ALTERNATIVE METHOD TO PERFORM THE ELLIPSE FITTING TO 2D DATA
    Ursu-Fischer, Nicolae
    ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2019, 62 (03): : 397 - 404
  • [8] COMPARISON OF 2D AND 3D FETAL ADRENAL GLAND VOLUME MEASUREMENT
    Turan, Ozhan
    Turan, Sifa
    Funai, Edmund
    Buhimschi, Irina A.
    Copel, Joshua
    Harman, Christopher
    Baschat, Ahmet
    Buhimschi, Catalin S.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2008, 199 (06) : S219 - S219
  • [9] A 2D volume conservative numerical model of hydraulic fracturing
    Wangen, Magnus
    COMPUTERS & STRUCTURES, 2017, 182 : 448 - 458
  • [10] Anthropometric Measurement Technology Using 2D Images
    Shah, Chinmay
    Shah, Jaineel
    Shaikh, Maruf
    Sandhu, Harshit
    Natu, Prachi
    PROCEEDINGS OF SECOND INTERNATIONAL CONFERENCE ON SUSTAINABLE EXPERT SYSTEMS (ICSES 2021), 2022, 351 : 127 - 142