Calibration of CMS Electromagnetic Calorimeter at LHC startup

被引:0
|
作者
Paramatti, Riccardo
机构
关键词
D O I
10.1088/1742-6596/293/1/012045
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The first 7 TeV LHC collisions recorded with the CMS detector have been used to perform a channel-by-channel calibration of the electromagnetic calorimeter (ECAL). Decays of pi(0) and eta into two photons as well as the azimuthal symmetry of the average energy deposition at a given pseudorapidity are utilized to equalize the response of the individual channels. The ECAL comprises a central barrel section and two endcaps. Based on an integrated luminosity of similar to 100 nb(-1), a channel-by-channel in-situ calibration precision of 1.15% has been achieved in the barrel ECAL in the pseudorapidity region vertical bar eta vertical bar < 0.8. The energy scale of the ECAL has been investigated and found to agree with the simulation to within 1% in the barrel and 3% in the endcaps.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Calibration of the CMS Electromagnetic Calorimeter at the LHC
    Leslie, D. E.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1196 - 1198
  • [2] Calibration of the CMS Electromagnetic Calorimeter with first LHC data
    Obertino, M. M.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2011, 215 : 182 - 184
  • [3] Calibration of the CMS electromagnetic calorimeter at the LHC start up
    Ghezzi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 88 - 89
  • [4] Calibration of the CMS electromagnetic calorimeter with LHC collision data
    Obertino, M. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 99 - 101
  • [5] Calibration of the CMS Electromagnetic Calorimeter with first LHC data
    Sola, V.
    COSMIC RAYS FOR PARTICLE AND ASTROPARTICLE PHYSICS, 2011, 6 : 52 - 57
  • [6] The CMS electromagnetic calorimeter at the LHC
    Ryan, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 217 - 219
  • [7] Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run2
    Cavallari, Francesca
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [8] Calibration and performance of the CMS Electromagnetic Calorimeter in LHC Run-II
    Kuo, C. M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):
  • [9] Calibration of the CMS electromagnetic calorimeter
    Paramatti, R
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 232 - 236
  • [10] Calibration of the electromagnetic calorimeter of CMS
    Massironi, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2010, 33 (06):