Seismic Vulnerability Assessment of a Shallow Two-Story Underground RC Box Structure

被引:48
|
作者
Huh, Jungwon [1 ]
Tran, Quang Huy [1 ]
Haldar, Achintya [2 ]
Park, Innjoon [3 ]
Ahn, Jin-Hee [4 ]
机构
[1] Chonnam Natl Univ, Dept Civil & Environm Engn, Yeosu 59626, Chonnam, South Korea
[2] Univ Arizona, Dept Civil Engn & Engn Mech, Tucson, AZ 85721 USA
[3] Hanseo Univ, Dept Civil Engn, Seosan 31962, Chungnam, South Korea
[4] Gyeongnam Natl Univ Sci & Technol, Dept Civil Engn, Jinju 52725, Gyeongnam, South Korea
来源
APPLIED SCIENCES-BASEL | 2017年 / 7卷 / 07期
基金
新加坡国家研究基金会;
关键词
two-story underground structure; fragility curve; GRAMBS; maximum likelihood; Latin hypercube sampling; pushover analysis;
D O I
10.3390/app7070735
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Tunnels, culverts, and subway stations are the main parts of an integrated infrastructure system. Most of them are constructed by the cut-and-cover method at shallow depths (mainly lower than 30 m) of soil deposits, where large-scale seismic ground deformation can occur with lower stiffness and strength of the soil. Therefore, the transverse racking deformation (one of the major seismic ground deformation) due to soil shear deformations should be included in the seismic design of underground structures using cost- and time-efficient methods that can achieve robustness of design and are easily understood by engineers. This paper aims to develop a simplified but comprehensive approach relating to vulnerability assessment in the form of fragility curves on a shallow two-story reinforced concrete underground box structure constructed in a highly-weathered soil. In addition, a comparison of the results of earthquakes per peak ground acceleration (PGA) is conducted to determine the effective and appropriate number for cost- and time-benefit analysis. The ground response acceleration method for buried structures (GRAMBS) is used to analyze the behavior of the structure subjected to transverse seismic loading under quasi-static conditions. Furthermore, the damage states that indicate the exceedance level of the structural strength capacity are described by the results of nonlinear static analyses (or so-called pushover analyses). The Latin hypercube sampling technique is employed to consider the uncertainties associated with the material properties and concrete cover owing to the variation in construction conditions. Finally, a large number of artificial ground shakings satisfying the design spectrum are generated in order to develop the seismic fragility curves based on the defined damage states. It is worth noting that the number of ground motions per PGA, which is equal to or larger than 20, is a reasonable value to perform a structural analysis that produces satisfactory fragility curves.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Seismic Performance Evaluation of Two-story Dhajji-dewari Traditional Structure
    Ali, Qaisar
    Ahmad, Naveed
    Ashraf, Muhammad
    Schacher, Tom
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2022, 16 (08) : 1233 - 1251
  • [2] Seismic performance of two-story and three-span underground subway station structure under different foundation isolation cases
    Zhang G.
    Zhuang H.
    Xu Z.
    Wang J.
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2023, 42 (11): : 27 - 41
  • [3] Comparative analysis on seismic performance of two-story subway underground station structures with different isolating systems
    Zhuang H.-Y.
    Li S.
    Wang W.
    Chen G.-X.
    [J]. Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2023, 36 (02): : 379 - 388
  • [4] Seismic Behavior of Two-story Brick Masonry Building
    An, Dong
    Qu, Tiejun
    Liang, Jianwen
    [J]. APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 1456 - +
  • [5] Measured seismic behavior of a two-story masonry building
    Kingsley, GR
    Magenes, G
    Calvi, GM
    [J]. WORLDWIDE ADVANCES IN STRUCTURAL CONCRETE AND MASONRY, 1996, : 123 - 134
  • [6] Recycled Plastic Lumber walls for one and two-story housing: An assessment of their seismic performance
    Herrera, Juan P.
    Bedoya-Ruiz, Daniel
    Hurtado, Jorge E.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 65
  • [7] Seismic vulnerability assessment of a RC structure before and after FRP retrofitting
    Desprez, Cedric
    Kotronis, Panagiotis
    Mazars, Jacky
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2015, 13 (02) : 539 - 564
  • [8] Seismic vulnerability assessment of a RC structure before and after FRP retrofitting
    Cédric Desprez
    Panagiotis Kotronis
    Jacky Mazars
    [J]. Bulletin of Earthquake Engineering, 2015, 13 : 539 - 564
  • [9] Cyclic performance of two-story ductile RC frames with infill walls
    Yeh, Yung-Hsin
    Liao, Wen-L
    [J]. Proceedings of the ASME Pressure Vessels and Piping Conference 2005, Vol 8, 2005, 8 : 259 - 264
  • [10] Experimental seismic behavior of a two-story CLT platform building
    van de Lindt, John W.
    Furley, Jace
    Amini, M. Omar
    Pei, Shiling
    Tamagnone, Gabriele
    Barbosa, Andre R.
    Rammer, Doug
    Line, Philip
    Fragiacomo, Massimo
    Popovski, Marjan
    [J]. ENGINEERING STRUCTURES, 2019, 183 : 408 - 422