The L3 lead-scintillating fiber calorimeter

被引:107
|
作者
Basti, G
Campanelli, M
Cavallari, F
deNotaristefani, F
Diemoz, M
Faccini, R
Ferroni, F
Iaciofano, A
Leonardi, E
Longo, E
Organtini, G
Paoletti, S
Boucham, A
Camberlin, B
Karyotakis, Y
Lesueur, J
Cecchi, C
Lebeau, M
Tsipolitis, Y
机构
[1] CERN, DIV PPE, CH-1211 GENEVA 23, SWITZERLAND
[2] UNIV ROMA LA SAPIENZA, I-00185 ROME, ITALY
[3] IST NAZL FIS NUCL, I-00185 ROME, ITALY
[4] LAB ANNECY LE VIEUX PHYS PARTICULES, IN2P3, CNRS, F-74941 ANNECY LE VIEUX, FRANCE
[5] UNIV GENEVA, CH-1211 GENEVA 4, SWITZERLAND
[6] CARNEGIE MELLON UNIV, PITTSBURGH, PA 15213 USA
关键词
D O I
10.1016/0168-9002(96)00206-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the construction and test of a lead-scintillating fiber (spaghetti) calorimeter built to fill the gap between endcaps and barrel in the L3 BGO detector. Results from test-beam, as well as MC simulations for the prototypes and for the full detector, are presented.
引用
收藏
页码:293 / 298
页数:6
相关论文
共 50 条
  • [1] A lead-scintillating fiber calorimeter to increase L3 hermeticity
    Basti, G
    Boucham, A
    Camberlin, B
    Campanelli, M
    Cavallari, F
    Cecchi, C
    deNotaristefani, F
    Diemoz, M
    Faccini, R
    Ferroni, F
    Karyotakis, Y
    Lebeau, M
    Leonardi, E
    Lesueur, J
    Longo, E
    Organtini, G
    Paoletti, S
    Tsipolitis, Y
    [J]. NUCLEAR PHYSICS B, 1997, : 210 - 213
  • [2] Completion of the L3 em calorimeter with a lead-scintillating fibers spaghetti calorimeter
    Basti, G
    Boucham, A
    Campanelli, M
    Cecchi, C
    deNotaristefani, F
    Diemoz, M
    Ferroni, F
    Iaciofano, A
    Janssen, B
    Karyotakis, Y
    Lebeau, M
    Lesueur, J
    Longo, E
    Organtini, G
    Tsipolitis, Y
    [J]. NUCLEAR PHYSICS B, 1995, : 132 - 137
  • [3] Performance of the CHORUS lead-scintillating fiber calorimeter
    Buontempo, S
    Capone, A
    Cocco, AG
    Depedis, D
    DiCapua, E
    Dore, U
    Ereditato, A
    Ferroni, M
    Fiorillo, G
    Garufi, F
    Loverre, PF
    Luppi, C
    Macina, D
    MarchettiStasi, F
    Mazzoni, MA
    Messina, M
    Migliozzi, P
    Palladino, V
    Piredda, G
    Ricciardi, S
    Righini, P
    Saitta, B
    Santacesaria, R
    Strolin, P
    Zucchelli, P
    [J]. NUCLEAR PHYSICS B, 1997, : 198 - 203
  • [4] Study on angular resolution of lead-scintillating fiber electromagnetic calorimeter
    Wang, XB
    Chen, GM
    Li, ZH
    Chen, G
    Yang, M
    Yang, ZY
    Zhang, SH
    Lu, YS
    Chen, HS
    Li, XQ
    [J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (11): : 1071 - 1076
  • [5] The E864 lead-scintillating fiber hadronic calorimeter
    Armstrong, TA
    Barish, K
    Bennett, SJ
    Cormier, TM
    Cernej, R
    Chikanian, A
    Coe, SD
    Davies, R
    Dee, PR
    Diebold, GE
    Fachini, P
    Finch, E
    George, NK
    Greene, SV
    Haridas, P
    Hill, JC
    Hirsch, A
    Huang, HZ
    Hoversten, RA
    Kim, B
    Kumar, BS
    Lajoie, JG
    Li, Q
    Li, Y
    Libby, B
    Maguire, CF
    Majka, RD
    Munhoz, MG
    Murgatroyd, JT
    Nagle, JL
    Petridis, AN
    Pless, IA
    Pope, JK
    Pruneau, CA
    Riso, J
    Rabin, MSZ
    Reid, JD
    Rotondo, FS
    Slaughter, AJ
    Sandweiss, J
    Scharenberg, R
    Sheen, J
    Tincknell, M
    Rimai, A
    Van Buren, G
    Wilson, WK
    Wohn, FK
    Zhao, K
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (02): : 227 - 258
  • [6] Studies on high energy γ trigger of lead-scintillating fiber electromagnetic calorimeter
    Yang, ZY
    Chen, GM
    Chen, G
    Yang, M
    Wang, XB
    Liu, ZH
    Zhang, SH
    Lü, YS
    Chen, HS
    [J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (10): : 1086 - 1089
  • [7] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    Li Zu-Hao
    Wang Ling-Yu
    Xu Wei-Wei
    Chen Guo-Ming
    Lu Yu-Sheng
    Chen He-Sheng
    [J]. CHINESE PHYSICS C, 2013, 37 (02)
  • [8] CONSTRUCTION AND PERFORMANCE OF THE LEAD-SCINTILLATING FIBER CALORIMETER PROTOTYPES FOR THE KLOE DETECTOR
    ANTONELLI, A
    ANTONELLI, M
    BARBIELLINI, G
    BARONE, M
    BERTOLUCCI, S
    BIANCO, S
    BINI, C
    BLOISE, C
    BOLOGNESI, V
    BOSSI, F
    CAMPANA, P
    CERVELLI, F
    CALOI, R
    CORDELLI, M
    DEZORZI, G
    DICOSIMO, G
    DIDOMENICO, A
    ERRIQUEZ, O
    FABBRI, FL
    FARILLA, A
    FERRARI, A
    FRANZINI, P
    GARUFI, F
    GAUZZI, P
    GERO, E
    GIOVANNELLA, S
    HAYDAR, R
    INCAGLI, M
    KEEBLE, L
    KIM, W
    LANFRANCHI, G
    LEEFRANZINI, J
    MARTINI, A
    MARTINIS, A
    MISCETTI, S
    MURTAS, F
    PARRI, A
    PASSERI, A
    SARWAR, S
    SCURI, F
    SPIRITI, E
    TORTORA, L
    WANG, XL
    WOLFLE, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 354 (2-3): : 352 - 363
  • [9] Correction of PMT position effect for a lead-scintillating fiber electromagnetic calorimeter
    李祖豪
    王玲玉
    许伟伟
    陈国明
    吕雨生
    陈和生
    [J]. Chinese Physics C, 2013, 37 (02) : 68 - 71
  • [10] Dead cell and side leakage correction for a lead-scintillating fiber electromagnetic calorimeter
    张诚
    李祖豪
    唐志成
    Suzan Basegmez du Pree
    张劭文
    王薛强
    杨民
    陈国明
    陈和生
    [J]. Chinese Physics C, 2016, (09) : 137 - 141